Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods

被引:3
|
作者
Chatzaraki, Vasiliki [1 ,2 ]
Kubik-Huch, Rahel A. [1 ]
Thali, Michael [2 ]
Niemann, Tilo [1 ]
机构
[1] Kantonsspital Baden, Inst Radiol, Ergel 1, CH-5404 Baden, Switzerland
[2] Univ Zurich, Inst Forens Med, Zurich, Switzerland
关键词
Computed tomography angiography; thorax; radiographic image enhancement; contrast to noise ratio; image enhancement; TUBE-VOLTAGE SELECTION; AORTIC CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-ARTERY; REDUCTION; OPACIFICATION; PROTOCOL; DETECTOR;
D O I
10.1177/02841851211041813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. Purpose To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. Material and Methods A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. Results The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. Conclusion We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
引用
收藏
页码:1353 / 1362
页数:10
相关论文
共 50 条
  • [31] Assessment of subjective image quality, contrast to noise ratio and modulation transfer function in the middle ear using a novel full body cone beam computed tomography device
    Anssi-Kalle Heikkinen
    Valtteri Rissanen
    Antti A. Aarnisalo
    Kristofer Nyman
    Saku T. Sinkkonen
    Juha Koivisto
    BMC Medical Imaging, 23
  • [32] Assessment of subjective image quality, contrast to noise ratio and modulation transfer function in the middle ear using a novel full body cone beam computed tomography device
    Heikkinen, Anssi-Kalle
    Rissanen, Valtteri
    Aarnisalo, Antti A.
    Nyman, Kristofer
    Sinkkonen, Saku T.
    Koivisto, Juha
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [33] Deep learning image reconstruction algorithm for carotid dual-energy computed tomography angiography: evaluation of image quality and diagnostic performance
    Jiang, Chenyu
    Jin, Dan
    Liu, Zhuoheng
    Zhang, Yan
    Ni, Ming
    Yuan, Huishu
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [34] Advanced virtual monoenergetic imaging algorithm for lower extremity computed tomography angiography: effects on image quality, artifacts, and peripheral arterial disease evaluation
    Hwang, Jung Han
    Kang, Jin Mo
    Park, Suyoung
    Park, So Hyun
    Kim, Jeong Ho
    Lee, Ki Hyun
    Shin, Ji Hoon
    Pak, Seong Yong
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (01): : 175 - 182
  • [35] Optimization of hybrid iterative reconstruction level and evaluation of image quality and radiation dose for pediatric cardiac computed tomography angiography
    Yang, Lin
    Zhuang, Jian
    Huang, Meiping
    Liang, Changhong
    Liu, Hui
    PEDIATRIC RADIOLOGY, 2017, 47 (01) : 31 - 38
  • [36] Image quality, contrast enhancement and radiation dose of electrocardiograph- versus non-electrocardiograph-triggered computed tomography angiography of the aorta
    Wong, Ying Mei
    Ong, Ching Ching
    Liang, Chong Ri
    Tan, Choon Ann
    Teo, Lynette Li San
    SINGAPORE MEDICAL JOURNAL, 2024, 65 (02) : 84 - 90
  • [37] Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings
    Chian, Teo Chee
    Nassir, Norziana Mat
    Ibrahim, Mohd Izuan
    Yusof, Ahmad Khairuddin Md
    Sabarudin, Akmal
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (01) : 48 - 58
  • [38] Effect of different injection rates and doses of contrast medium on the image quality of computed tomographic angiography in African grey parrots (Psittacus erithacus)
    Wang, Wen-Lin
    Chang, Fang-Lun
    Yu, Pin-Huan
    BMC VETERINARY RESEARCH, 2022, 18 (01)
  • [39] Effect of different injection rates and doses of contrast medium on the image quality of computed tomographic angiography in African grey parrots (Psittacus erithacus)
    Wen-Lin Wang
    Fang-Lun Chang
    Pin-Huan Yu
    BMC Veterinary Research, 18
  • [40] Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients
    Pontana, Francois
    Pagniez, Julien
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Duhamel, Alain
    Remy, Jacques
    Remy-Jardin, Martine
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 627 - 635