Quantifying image quality in chest computed tomography angiography: Evaluation of different contrast-to-noise ratio measurement methods

被引:3
|
作者
Chatzaraki, Vasiliki [1 ,2 ]
Kubik-Huch, Rahel A. [1 ]
Thali, Michael [2 ]
Niemann, Tilo [1 ]
机构
[1] Kantonsspital Baden, Inst Radiol, Ergel 1, CH-5404 Baden, Switzerland
[2] Univ Zurich, Inst Forens Med, Zurich, Switzerland
关键词
Computed tomography angiography; thorax; radiographic image enhancement; contrast to noise ratio; image enhancement; TUBE-VOLTAGE SELECTION; AORTIC CT ANGIOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-ARTERY; REDUCTION; OPACIFICATION; PROTOCOL; DETECTOR;
D O I
10.1177/02841851211041813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast-to-noise ratio is used to objectively evaluate image quality in chest computed tomography angiography (CTA). Different authors define and measure contrast-to-noise ratio using different methods. Purpose To summarize and evaluate the different contrast-to-noise ratio calculation formulas in the current literature. Material and Methods A systematic review of the recent literature for studies using contrast-to-noise ratio was performed. Contrast-to-noise ratio measurement methods reported by the different authors were recorded and reproduced in three patients who underwent chest CTA in our department for exploring variations among the different measurement methods. Results The search resulted in 109 articles, of which 26 were included. The studies involved 69 different measurements and overall, three different formula patterns. In all three, aorta and pulmonary arteries comprised the objects of interest in the numerator. In the denominator, standard deviation of the attenuation of the object of interest itself or of another background were used to reflect image noise. Some authors averaged the ratio values at different levels to obtain global ratio values. Using the object of interest itself for image noise calculation in the denominator compared to the usage of another background caused the most prominent variances of contrast-to-noise ratio between the two different protocols used for the reproduction of the measurements. Conclusion We recommend using the standard deviation of the attenuation of a background indicator as image noise rather than the object of interest itself for more reliable and comparative values. Global contrast-to-noise ratios based on averaging the values of different measurement levels should be avoided.
引用
收藏
页码:1353 / 1362
页数:10
相关论文
共 50 条
  • [21] Evaluation of Image Quality for 7 Iterative Reconstruction Algorithms in Chest Computed Tomography Imaging: A Phantom Study
    Jensen, Kristin
    Hagemo, Guro
    Tingberg, Anders
    Steinfeldt-Reisse, Claudius
    Mynarek, Georg Karl
    Rivero, Rodriguez Jezabel
    Fosse, Erik
    Martinsen, Anne Catrine
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (05) : 673 - 680
  • [22] Image quality evaluation for CARE kV technique combined with iterative reconstruction for chest computed tomography scanning
    Yang, Bin
    Li, Zheng-Liang
    Gao, Yi
    Yang, Ya-Ying
    Zhao, Wei
    MEDICINE, 2017, 96 (11)
  • [23] Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography
    Boos, Johannes
    Kroepil, Patric
    Klee, Dirk
    Heusch, Philipp
    Schimmoeller, Lars
    Schaper, Joerg
    Antoch, Gerald
    Lanzman, Rotem S.
    PEDIATRIC RADIOLOGY, 2014, 44 (09) : 1065 - 1069
  • [24] Radiation Dose and Image Noise Evaluation in Coronary Computed Tomography Angiography (CCTA) Using an Iterative Reconstruction Algorithm
    Kordolaimi, Sofia D.
    Argentos, Stylianos
    Stathis, George
    Alexiou, Antigoni
    Pantos, Ioannis
    Katritsis, Demosthenes G.
    Kelekis, Nikolaos L.
    Seimenis, Ioannis
    Efstathopoulos, Efstathios P.
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (03) : 184 - 190
  • [25] Comparison of Coronary Computed Tomography Angiography Image Quality With High-concentration and Low-concentration Contrast Agents The Randomized CONCENTRATE Trial
    Im, Dong Jin
    Kim, Yun-Hyeon
    Choo, Ki Seok
    Kang, Joon-Won
    Jung, Jung Im
    Won, Yoodong
    Kim, Hyo Rim
    Chung, Myung Hee
    Han, Kyunghwa
    Choi, Byoung Wook
    JOURNAL OF THORACIC IMAGING, 2023, 38 (02) : 120 - 127
  • [26] Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality
    Renapurkar, Rahul D.
    Primak, Andrew
    Azok, Joseph
    Lempel, Jason
    Tandon, Yasmeen
    Bullen, Jennifer
    Dong, Frank
    Karim, Wadih
    Graham, Ruffin
    EUROPEAN RADIOLOGY, 2017, 27 (08) : 3283 - 3289
  • [27] High-Pitch Dual-Source Computed Tomography Renal Angiography Comparison With Conventional Low-Pitch Computed Tomography Angiography: Image Quality, Contrast Medium Volume, and Radiation Dose
    Pang, LiFang
    Zhao, Yue
    Dong, HaiPeng
    Shi, HongCheng
    Yang, WenJie
    Zhang, Huan
    Yan, FuHua
    Liu, Bo
    Yan, Jing
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 737 - 740
  • [28] Impact of AI-Based Post-Processing on Image Quality of Non-Contrast Computed Tomography of the Chest and Abdomen
    Drews, Marcel A.
    Demircioglu, Aydin
    Neuhoff, Julia
    Haubold, Johannes
    Zensen, Sebastian
    Opitz, Marcel K.
    Forsting, Michael
    Nassenstein, Kai
    Bos, Denise
    DIAGNOSTICS, 2024, 14 (06)
  • [29] A Comparison of the Image Quality and Radiation Dose With Routine Computed Tomography and the Latest Gemstone Spectral Imaging Combination of Different Scanning Protocols in Computed Tomography Angiography of the Kidney
    Zhao, Yong-Xia
    Suo, Hong-Na
    Zuo, Zi-Wei
    Xu, Ying-Jin
    Chang, Jin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (02) : 263 - 270
  • [30] Comparison of image quality and radiation dose of different scanning methods used for computed tomography of the unilateral shoulder
    Jiang, Dongdong
    Wang, Yanan
    Zhang, Peng
    Liu, Zhenyu
    ACTA RADIOLOGICA, 2023, 64 (05) : 1919 - 1926