Inductive sensor based on nano-scale SQUIDs

被引:27
作者
Hao, L [1 ]
Macfarlane, JC
Lam, SKH
Foley, CP
Josephs-Franks, P
Gallop, JC
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Univ Strathclyde, Dept Phys, Glasgow G4 0NG, Lanark, Scotland
[3] CSIRO, Lindfield, NSW 2070, Australia
关键词
nanometer bolometer; photon or particle detector; SQUID; superconductor;
D O I
10.1109/TASC.2005.849892
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Detectors with sufficient sensitivity to resolve the energy of single photons and particles combined with rapid response times are becoming increasingly important. We describe work in progress on a recently-proposed type of sensor, which we have named the Inductive Superconducting Mransition Edge Detector (ISTED). We have theoretically estimated the energy sensitivity of such a sensor, in the case where the heat absorber is incorporated within the sensitive area of a nano-scale SQUID which acts as an inductive readout device. Recent results on the experimental characterization of prototype devices in the temperature range 15-8 K are presented, and ongoing work which is intended to achieve smaller device dimensions together with lower operating temperatures is described.
引用
收藏
页码:514 / 517
页数:4
相关论文
共 35 条
[31]   Colorimetric sensor and LDI-MS detection of biogenic amines in food spoilage based on porous PLA and graphene oxide [J].
Siripongpreda, Tatiya ;
Siralertmukul, Krisana ;
Rodthongkum, Nadnudda .
FOOD CHEMISTRY, 2020, 329
[32]   SQUID-sensor-based ultra-low-field MRI calibration with phantom images: Towards quantitative imaging [J].
Dabek, Juhani ;
Vesanen, Panu T. ;
Zevenhoven, Koos C. J. ;
Nieminen, Jaakko O. ;
Sepponen, Raimo ;
Ilmoniemi, Risto J. .
JOURNAL OF MAGNETIC RESONANCE, 2012, 224 :22-31
[33]   Postmortem analysis of a failed liquid nitrogen-cooled prepolarization coil for SQUID sensor-based ultra-low field magnetic resonance [J].
Hwang, Seong-min ;
Kim, Kiwoong ;
Yu, Kwon Kyu ;
Lee, Seong-Joo ;
Shim, Jeong Hyun .
PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2014, 16 (04) :44-48
[34]   Cost-effective formaldehyde assay platform for multi-sample analysis in one run based on pervaporation coupled with a biodegradable sensor and a simple heat control unit [J].
Yeerum, Chonnipa ;
Kiwfo, Kanokwan ;
Kesonkan, Kullapon ;
Grudpan, Kate ;
Vongboot, Monnapat .
ANALYTICAL SCIENCES, 2023, 39 (05) :653-662
[35]   A Tunable Optimized Low-Temperature Sensor Based on the Hybrid Photonic Crystals (F4/Bg5/F4) and (Bg5/F4/Bg5) [J].
Zaghdoudi, Jihene ;
Baraket, Zina ;
Kanzari, Mounir .
JOURNAL OF SUPERCONDUCTIVITY AND NOVEL MAGNETISM, 2019, 32 (08) :2605-2612