Fibrinogen measurement by a novel point-of-care device with whole blood: comparison of values against Clauss method

被引:6
|
作者
Okahara, Shoko [1 ]
Handoh, Tetsuya [2 ]
Wakita, Mitsuru [2 ]
Yamamoto, Takamasa [2 ]
Misawa, Shigeki [2 ]
Miida, Takashi [2 ]
Sumikura, Hiroyuki [1 ]
机构
[1] Juntendo Univ Hosp, Dept Anesthesiol, Bunkyo Ku, 3-1-3 Hongo, Tokyo 1138431, Japan
[2] Juntendo Univ Hosp, Dept Clin Lab, Bunkyo Ku, 3-1-3 Hongo, Tokyo 1138431, Japan
关键词
Clauss method; FibCare; Fibrinogen; Hemorrhage; Point-of-care testing; TRAUMA; PLASMA;
D O I
10.1007/s00540-021-02987-9
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Timely fibrinogen replacement is key to treating critical hemorrhage. Measuring fibrinogen concentration by conventional laboratory tests requires centrifugation of blood samples and is often time-consuming. A point-of-care testing device (A&T, Yokohama, Japan), CG02N, has been available in Japan since 2011 to measure fibrinogen concentration without centrifugation. However, it has not been widely used as it requires dilution of blood samples using manual micropipetting. To further speed up and simplify the fibrinogen measurement, an improved device called FibCare (Atom Medical, Tokyo, Japan) was developed to avoid diluting blood samples. The purpose of this study is to verify the reliability of FibCare against laboratory measurement using the Clauss method. Fibrinogen concentrations with 60 sodium citrated whole blood samples were measured by both FibCare and Clauss methods in the laboratory. Measured values with the Clauss method were distributed in the 88-300 mg/dL range. By comparing these results, a significant positive correlation was observed between the FibCare and Clauss method (Y = 12.402 + 0.982 X; R = 0.891; P < 0.01). The study indicated that FibCare allows accurate measurement of fibrinogen concentration and shows a possibility to contribute to optimal fibrinogen replacement therapy during critical hemorrhage.
引用
收藏
页码:757 / 760
页数:4
相关论文
共 50 条
  • [21] Toward development of a point-of-care assay of enoxaparin anticoagulant activity in whole blood
    Inchiosa, Mario A., Jr.
    Pothula, Suryanarayana
    Kubal, Keshar
    Sanchala, Vajubhai T.
    Navarro, Iris
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2011, 32 (01) : 47 - 53
  • [22] Whole Blood Point-of-Care Testing for Incomplete Reversal With Idarucizumab in Supratherapeutic Dabigatran
    Takeshita, Shusuke
    Tanaka, Kenichi A.
    Sawa, Teiji
    Sanda, Masashi
    Mizobe, Toshiki
    Ogawa, Satoru
    ANESTHESIA AND ANALGESIA, 2020, 130 (02) : 535 - 541
  • [23] Use of Stabilized Whole Blood for Glucose Proficiency Testing at Point-of-Care Sites
    Liang, Shu-Ling
    Schmith, Eric
    Hunsley, Bradford
    Sornson, Hal
    Clarke, William
    POINT OF CARE, 2008, 7 (02): : 64 - 68
  • [24] A novel, point-of-care, whole-blood assay utilizing dielectric spectroscopy is sensitive to coagulation factor replacement therapy in haemophilia A patients
    Maji, Debnath
    Nayak, Lalitha
    Martin, Janet
    Sekhon, Ujjal D. S.
    Sen Gupta, Anirban
    Mohseni, Pedram
    Suster, Michael A.
    Ahuja, Sanjay P.
    HAEMOPHILIA, 2019, 25 (05) : 885 - 892
  • [25] A portable point-of-care testing device for forward blood typing with hemophilia diagnosis
    Yaw-Jen Chang
    Shang-Fen Yeh
    Pin-Jyun Chen
    Biomedical Microdevices, 2023, 25
  • [26] A miniaturized photoacoustic device with laptop readout for point-of-care testing of blood glucose
    Zhang, Ya-Jie
    Chen, Shuai
    Yu, Yong-Liang
    Wang, Jian-Hua
    TALANTA, 2020, 209
  • [27] A portable point-of-care testing device for forward blood typing with hemophilia diagnosis
    Chang, Yaw-Jen
    Yeh, Shang-Fen
    Chen, Pin-Jyun
    BIOMEDICAL MICRODEVICES, 2023, 25 (04)
  • [28] Evaluation of a novel in-line point-of-care blood gas analyser
    Miles, L. F.
    Giraud, K.
    Ferris, R.
    Klein, A. A.
    Martinez, G. C.
    Jenkins, D. P.
    Saulankey, K.
    ANAESTHESIA, 2016, 71 (09) : 1044 - 1052
  • [29] Noncitrated Whole Blood Is Optimal for Evaluation of Postinjury Coagulopathy With Point-of-Care Rapid Thrombelastography
    Kashuk, Jeffry L.
    Moore, Ernest E.
    Le, Tuan
    Lawrence, Jerry
    Pezold, Michael
    Johnson, Jeffrey L.
    Cothren, Clay C.
    Biffl, Walter L.
    Barnett, Carlton
    Sabel, Allison
    JOURNAL OF SURGICAL RESEARCH, 2009, 156 (01) : 133 - 138
  • [30] Development and calibration of a new point-of-care test for the determination of NT-proBNP in whole blood
    Bertsch, Thomas
    Dikkeschei, Bert
    Gurr, Eberhard
    Hayen, Wiebke
    Jorgensen, Bo
    Lotz, Johannes
    Mueller-Bardorff, Margit
    Ordonez-Llanos, Jordi
    Schulz, Ilse
    Spinke, Juergen
    Thiele, Marcel
    Zerback, Rainer
    CLINICAL LABORATORY, 2007, 53 (7-8) : 423 - 431