Photon Beam Softening Coefficients Evaluation for a 6 MeV Photon Beam for an Aluminum Slab: Monte Carlo Study Using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP Code

被引:11
|
作者
Bencheikh, Mohamed [1 ]
Maghnouj, Abdelmajid [1 ]
Tajmouati, Jaouad [1 ]
机构
[1] Univ Sidi Mohamed Ben Abdellah, Fac Sci Dhar El Mahraz, Dept Phys, LISTA Lab, Fes, Morocco
关键词
aluminum slab; Monte Carlo simulation; photon beam softening; BEAMnrc code; BEAMDP code; DOSIMETRIC PROPERTIES; ELECTRON-BEAM; DISTRIBUTIONS; ACCELERATOR; SENSITIVITY; SIMULATION; QUALITY; LEAKAGE;
D O I
10.3103/S0027134917030043
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the flattening filter and the later was replaced by the aluminum slab with variable thickness. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3 mm for distance to agreement. The purpose was to investigate aluminum material attenuation and beam softening coefficients as a function of the inserted aluminum slab thickness and of off-axis distance. The attenuation and beam softening coefficients were not identical for the same off-axis distance and they varied as a function of aluminum slab thickness. The results of our study were shown that the beam softening coefficients were varied with thickness beam modifier material used for beam softening and the off-axis distance inside the irradiation field. Thereafter, the softening coefficient a (1) have a maximum of 2.5 x 10(-1) cm(-1) for the aluminum slab thickness of 1 mm, 1.4 x 10(-1) cm(-1) for the aluminum slab thickness of 1.5 mm and 4.47 x 10(-2) cm(-1) for the aluminum slab thickness of 2 mm. The maximum of the second softening coefficient a (2) was 1.02 x 10(-2) cm(-2) for the aluminum slab thickness of 1 mm, was 1.92 x 10(-2) cm(-2) for the aluminum slab thickness of 1.5 mm and was 1.93 x 10(-2) cm(-2) for the aluminum slab thickness of 2 mm. Our study can be a basic investigation of photon beam softening material that will be used in the future linac configuration and also in the photon beam modifiers.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 33 条
  • [21] Dosimetric properties of a flattening filter-free 6-MV photon beam: A Monte Carlo study
    Mesbahi A.
    Mehnati P.
    Keshtkar A.
    Farajollahi A.
    Radiation Medicine, 2007, 25 (7): : 315 - 324
  • [22] Investigation of ionization chamber perturbation factors using proton beam and Fano cavity test for the Monte Carlo simulation code PHITS
    Yuya Nagake
    Keisuke Yasui
    Hiromu Ooe
    Masaya Ichihara
    Kaito Iwase
    Toshiyuki Toshito
    Naoki Hayashi
    Radiological Physics and Technology, 2024, 17 : 280 - 287
  • [23] Investigation of ionization chamber perturbation factors using proton beam and Fano cavity test for the Monte Carlo simulation code PHITS
    Nagake, Yuya
    Yasui, Keisuke
    Ooe, Hiromu
    Ichihara, Masaya
    Iwase, Kaito
    Toshito, Toshiyuki
    Hayashi, Naoki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 280 - 287
  • [24] Investigation of field output factors using IAEA-AAPM TRS-483 code of practice recommendations and Monte Carlo simulation for 6 MV photon beams
    Yabsantia, Sumalee
    Suriyapee, Sivalee
    Phaisangittisakul, Nakorn
    Oonsiri, Sornjarod
    Sanghangthum, Taweap
    Seuntjens, Jan
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 22
  • [25] Virtual dosimetry study with three cone-beam breast computed tomography scanners using a fast GPU-based Monte Carlo code
    Mettivier, Giovanni
    Lai, Youfang
    Jia, Xun
    Russo, Paolo
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04)
  • [26] Inhomogeneity effect in Varian Trilogy Clinac iX 10 MV photon beam using EGSnrc and Geant4 code system
    Yani, S.
    Rhani, M. F.
    Haryanto, F.
    Arif, I
    6TH ASIAN PHYSICS SYMPOSIUM, 2016, 739
  • [27] Quantitative analysis of optical properties of flowing blood using a photon-cell interactive Monte Carlo code: effects of red blood cells' orientation on light scattering
    Sakota, Daisuke
    Takatani, Setsuo
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (05)
  • [28] AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE
    Panettieri, Vanessa
    Barsoum, Pierre
    Westermark, Mathias
    Brualla, Lorenzo
    Lax, Ingmar
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 94 - 101
  • [29] Evaluation of dosimetric parameters of small fields of 6 MV flattening filter free photon beam measured using various detectors against Monte Carlo simulation
    Mamballikalam, Gopinath
    Senthilkumar, S.
    Jayadevan, P. M.
    Jaon Bos, R. C.
    Ahamed Basith, P. M.
    Inippully, Rohit
    Shine, N. S.
    Clinto, C. O.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 332 - 339
  • [30] 3D imaging using combined neutron-photon fan-beam tomography: A Monte Carlo study
    Hartman, J.
    Yazdanpanah, A. Pour
    Barzilov, A.
    Regentova, E.
    APPLIED RADIATION AND ISOTOPES, 2016, 111 : 110 - 116