Metrological characterization of X-ray diffraction methods for determination of crystallite size in nano-scale materials

被引:344
作者
Uvarov, V. [1 ]
Popov, I. [1 ]
机构
[1] Hebrew Univ Jerusalem, Fac Nat Sci, Ctr Nanosci & Nanotechnol, Unit Nanoscop Charaterizat, IL-91904 Jerusalem, Israel
关键词
X-ray diffraction; crystallite size determination; anatase; nanocrystallites; statistical treatment;
D O I
10.1016/j.matchar.2006.09.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Crystallite size values were determined by X-ray diffraction methods for 210 TiO2 (anatase) nanocrystalline powders with crystallite size from 3 nm to 35 rum. Each X-ray diffraction pattern was processed using different free and commercial software. The crystallite size calculations were performed using Scherrer equation and Warren-Averbach method. Statistical treatment and comparative assessment of the obtained results were performed for the purpose of an ascertainment of statistical significance of the obtained differences. The average absolute divergence between results obtained with using Scherrer equation does not exceed 0.36 nm for the crystallites smaller than 10 nm, 0.54 nm for the range 10-15 nm and 2:4 nm for the range > 15 nm: We have also found that increasing the analysis time improves statistics, however does not affect the calculated crystallite sizes. The values of crystallite size determined from X-ray data were in good agreement with those obtained by imaging in a transmission electron microscope. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:883 / 891
页数:9
相关论文
共 24 条
[1]  
[Anonymous], 2004, Diffraction Analysis of the Microstructure of Materials
[2]   Size-strain line-broadening analysis of the ceria round-robin sample [J].
Balzar, D ;
Audebrand, N ;
Daymond, MR ;
Fitch, A ;
Hewat, A ;
Langford, JI ;
Le Bail, A ;
Louër, D ;
Masson, O ;
McCowan, CN ;
Popa, NC ;
Stephens, PW ;
Toby, BH .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2004, 37 :911-924
[3]   Fundamental parameters line profile fitting in laboratory diffractometers [J].
Cheary, RW ;
Coelho, AA ;
Cline, JP .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2004, 109 (01) :1-25
[4]  
CHEARY RW, SOFTWARE XFIT FOURYA
[5]   DETERMINATION OF CRYSTALLITE SIZE AND LATTICE-DISTORTIONS THROUGH X-RAY-DIFFRACTION LINE-PROFILE ANALYSIS - RECIPES, METHODS AND COMMENTS [J].
DELHEZ, R ;
DEKEIJSER, TH ;
MITTEMEIJER, EJ .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1982, 312 (01) :1-16
[6]  
Klug H.P., 1974, XRAY DIFFRACTION PRO, V2nd, P992
[7]   POWDER CELL - A program for the representation and manipulation of crystal structures and calculation of the resulting X-ray powder patterns [J].
Kraus, W ;
Nolze, G .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1996, 29 :301-303
[8]  
Krumm S., 1994, ACTA U CAROLINAE GEO, P253
[9]  
Lowry R., Concepts and applications of inferential statistics
[10]  
Marinkovic B., 2001, Mater Res, V4, P71, DOI DOI 10.1590/S1516-14392001000200005