Evaluation of antibiotic susceptibility test results: how guilty a laboratory could be?

被引:51
作者
Nassar, Mohamed S. M. [1 ]
Hazzah, Walaa A. [1 ]
Bakr, Wafaa M. K. [1 ]
机构
[1] Alexandria Univ, High Inst Publ Hlth, Dept Microbiol, Alexandria, Egypt
来源
JOURNAL OF THE EGYPTIAN PUBLIC HEALTH ASSOCIATION | 2019年 / 94卷 / 01期
关键词
CLSI; Mueller-Hinton agar; Inhibition zones; Disk diffusion method; Quality control;
D O I
10.1186/s42506-018-0006-1
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The selection of an appropriate antimicrobial is a challenging task for clinicians. The Kirby-Bauer disk diffusion method is one of the most widely practiced antimicrobial susceptibility tests (AST). It is affected by many factors among which are the media used. Mueller-Hinton agar (MHA) is the standard medium recommended in guidelines. However, these guidelines are not strictly adhered to in some developing countries. Objectives: Validation of AST results on nutrient agar (NA) medium used as a substitute for MHA by some microbiology laboratories in Alexandria, Egypt. Methods: A total of 149 clinical bacterial isolates and 3 reference strains: Staphylococcus aureus (S. aureus) ATCC (R) 25923, Escherichia coli (E. coli) ATCC (R) 25922, and Pseudomonas aeruginosa (P. aeruginosa) ATCC (R) 27853 were comparatively challenged to antibiotics employing MHA and NA. Results: All antibiotics-reference bacterial strain challenges on NA compared to MHA were unacceptable (> 3 out of limit zones in 30 consecutive days). Considering clinical isolates, the frequency of very major, major, and minor errors on NA was highest in the case of P. aeruginosa (8.98%, 4.08%, and 14.7% respectively) followed by S. aureus (7.6%, 6%, and 8.8% respectively). On the other hand, the least frequency of errors was in the case of Enterobacteriaceae (0%, 0.4%, and 3.2% respectively). Conclusions and recommendations: Using NA in AST resulted in multiple errors and the high discrepancy in results compared to MHA making it unreliable for susceptibility testing. MHA should not be replaced by NA in AST. Following guidelines and QC measures for AST must be neither bypassed nor underestimated.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 14 条
  • [1] Aryal S, 2015, MUELLER HINTON AGAR
  • [2] CLSI, 2007, M7A7 CLSI
  • [3] CLSI, 2013, PERFORMANCE STANDARD
  • [4] CLSI (Clinical and Laboratory Standards Institute), 2010, M100S20 CLSI
  • [5] Donkor ES, 2007, INTERNET J MICROBIOL, V4, P1
  • [6] Comparison of direct disk diffusion and standard microtitre broth dilution susceptibility testing of blood culture isolates
    Edelmann, Andreas
    Pietzcker, Tim
    Wellinghausen, Nele
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2007, 56 (02) : 202 - 207
  • [7] FDA, US BATTL BUGS FIGHT
  • [8] Forbes B.A., 2007, BAILEY SCOTTS DIAGNO, V12th
  • [9] STUDY OF ANTIBIOTIC SENSITIVITY TESTING WITH PROPOSALS FOR SIMPLE UNIFORM METHODS
    GARROD, LP
    WATERWOR.PM
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1971, 24 (09) : 779 - &
  • [10] Comparison of commonly used antimicrobial susceptibility testing methods for evaluating susceptibilities of clinical isolates of Enterobacteriaceae and nonfermentative Gram-negative bacilli to cefoperazonee-sulbactam
    Jean, Shio-Shin
    Liao, Chun-Hsing
    Sheng, Wang-Huei
    Lee, Wen-Sen
    Hsueh, Po-Ren
    [J]. JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2017, 50 (04) : 454 - 463