Risk of clot formation with ionic and nonionic contrast media in cerebral angiography

被引:6
作者
Sato, E [1 ]
Saito, I [1 ]
机构
[1] KYORIN UNIV,SCH MED,DEPT NEUROSURG,MITAKA,TOKYO 181,JAPAN
关键词
ionic and nonionic contrast media; cerebral angiography; clot formation;
D O I
10.1016/S1076-6332(96)80301-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The introduction of low-osmolality contrast media has improved patient tolerance to angiographic procedures, How ever, nonionic contrast media map be associated with an increase in the risk of clot formation. The objective of this study was to test whether there is more clotting with nonionic agents than with ionic agents. Methods. Ninety-eight patients undergoing transfemoral cerebral angiography were randomly assigned to receive ionic (ioxaglate) (n = 62) or nonionic (iopamidol or iohexol) (n = 36) contrast material, Incidence of clot formation was examined by observation of catheters. Results. Clot formation was found in 4.8% of patients in the ionic contrast material group and 22.2% of patients in the nonionic contrast material group (P < .05). Conclusion. Nonionic contrast media resulted in a statistically significantly higher incidence of clot formation than ionic media during cerebral catheter angiography. These results suggest that ionic contrast media are preferable in patients with risk of thrombosis.
引用
收藏
页码:925 / 928
页数:4
相关论文
共 21 条
[1]  
BASHORE TM, 1988, CARDIOLOGY, V5, P4
[2]  
Bernstein E F, 1966, Invest Radiol, V1, P162, DOI 10.1097/00004424-196603000-00030
[3]   ROLE OF LOW-OSMOLALITY CONTRAST-MEDIA IN THROMBOEMBOLIC COMPLICATIONS - SCANNING ELECTRON-MICROSCOPY STUDY [J].
CASALINI, E .
RADIOLOGY, 1992, 183 (03) :741-744
[4]   SCANNING ELECTRON-MICROSCOPIC ANALYSIS OF CATHETERS DURING ROUTINE ANGIOGRAPHIC PROCEDURES - ROLE OF THE CONTRAST AGENT [J].
COROT, C ;
CORNILLAC, A ;
BELLEVILLE, J ;
ELOY, R ;
KUHN ;
JOFFRE ;
MARCO ;
PERNES ;
PUEL .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S96-S100
[5]  
COROT C, 1991, SEMIN HEMATOL, V28, P54
[6]   CATASTROPHIC THROMBUS DEVELOPMENT DESPITE SYSTEMIC HEPARINIZATION DURING CORONARY ANGIOPLASTY - POSSIBLE RELATIONSHIP TO NONIONIC CONTRAST [J].
DOOREY, AJ ;
STILLABOWER, ME ;
GALE, N ;
GOLDENBERG, EM .
CLINICAL CARDIOLOGY, 1992, 15 (02) :117-120
[7]   RISK OF THROMBOSIS DURING CORONARY ANGIOPLASTY WITH LOW OSMOLALITY CONTRAST-MEDIA [J].
ESPLUGAS, E ;
CEQUIER, A ;
JARA, F ;
MAURI, J ;
SOLER, T ;
SALA, J ;
SABATE, X .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (10) :1020-1024
[8]   INFLUENCE OF CONTRAST-MEDIA ON THROMBUS FORMATION DURING CORONARY ANGIOPLASTY [J].
GASPERETTI, CM ;
FELDMAN, MD ;
BURWELL, LR ;
ANGELLO, DA ;
HAUGH, KH ;
OWEN, RM ;
POWERS, ER .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) :443-450
[9]   THROMBOEMBOLIC COMPLICATIONS IN CORONARY ANGIOGRAPHY ASSOCIATED WITH THE USE OF NONIONIC CONTRAST-MEDIUM [J].
GROLLMAN, JH ;
LIU, CK ;
ASTONE, RA ;
LURIE, MD .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (03) :159-164
[10]   DIFFERING MECHANISMS OF CLOTTING INHIBITION BY IONIC AND NONIONIC CONTRAST AGENTS [J].
ING, JJ ;
SMITH, DC ;
BULL, BS .
RADIOLOGY, 1989, 172 (02) :345-348