Experimental investigation on composite insulators AC flashover performance with fan-shaped non-uniform pollution under electro-thermal stress

被引:43
|
作者
Savadkoohi, Ehsan Mohammadi [1 ]
Mirzaie, Mohammad [1 ]
Seyyedbarzegar, SeyyedMeysam [2 ]
Mohammadi, Mohsen [1 ]
Khodsuz, Masume [3 ]
Pashakolae, Mehrdad Ghorbani [1 ]
Ghadikolaei, Milad Biazar [1 ]
机构
[1] Babol Noshirvani Univ Technol, Dept Elect & Comp Engn, Babol Sar, Iran
[2] Shahrood Univ Technol, Fac Elect & Robot Engn, Shahrood, Iran
[3] Univ Sci & Technol Mazandaran, Fac Elect & Comp Engn, Behshahr, Iran
关键词
Composite insulator; Flashover voltage; Accelerated aging tests; Scanning electron microscopy; Fan-shaped non-uniform pollution; SILICONE-RUBBER; SURFACE DEGRADATION; VOLTAGE; PORCELAIN; GLASS; LINES;
D O I
10.1016/j.ijepes.2020.106142
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pollution deposition along with ultraviolet (UV) radiation and electro-thermal stress cause the composite insulators to face with critical conditions. The type of pollution which settles on insulators is not only uniform but also it can be non-uniform and uneven. In this study, the results of the uniform and fan-shaped non-uniform (FSNU) pollution tests on four various types of virgin and aged polymeric insulators under AC voltage are presented. To find the effects of accelerated aging on polymer chains of composite insulators, scanning electron microscopy (SEM) is carried out. Based on IEC 60507, the solid layer method is applied to settle pollution on the insulator surface. The results demonstrate that the flashover voltage of virgin and also aged samples decreased when pollution non-uniformity degree (J) increases from 1 to 13. The flashover voltage of studied insulators is reduced by increasing the occupation ratio (K). However, the impact of K was lesser than J on flashover voltage of the polymeric insulators. Investigated polymeric insulators have been aged up to six weeks (1000 h). Although the influence of two weeks (333 h) accelerated aging on flashover voltage and morphology of the composite insulators was not tangible, therefore flashover strength of the samples is decreased while the aging period time increases. Statistical analysis has been done to estimate the flashover voltage of accelerated aged composite insulators under uniform and FSNU pollution based on virgin insulators. The research aimed to select insulators in windy and sunny areas.
引用
收藏
页数:10
相关论文
共 41 条
  • [31] A new proposed dynamic arc model for flashover performance of a non-uniform polluted insulator string under HVAC stress
    El-Zohri, Emad H.
    Ziedan, H.
    Prochazka, R.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 119 : 278 - 286
  • [32] Effect of material composition distribution on the electro-thermal response of a non-uniform functionally graded metal line under a direct current field
    Ghosh, Abhishek Kumar
    Haque, Md Rejaul
    Ahmed, S. Reaz
    10TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2013), 2014, 90 : 206 - 212
  • [33] Experimental investigation on the thermal performance of high-concentrated photovoltaic module utilizing the thermal sink of a novel Fan-shaped plate pulsating heat pipe
    Wang, Wei-Wei
    Liu, Teng
    Guo, Jun-Zhe
    Li, Bin
    Zhang, Hong-Liang
    Cai, Yang
    Zhao, Fu-Yun
    Liu, Di
    APPLIED ENERGY, 2025, 377
  • [34] Dynamic response analysis of CRC+AC composite pavement under non-uniform three-way stress
    Li S.
    Zhang H.
    Cheng X.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2021, 52 (03): : 971 - 982
  • [35] Investigation of FRP Hot Stick Performance for 500 kVdc Applications Under Conditions of Pollution or Non-uniform Wetting
    McDermid, W.
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 36 - 39
  • [36] Experimental Investigation of the Effects of Non-Uniform Clothing Ensembles on the Occupants' Thermal Perceptions under a Local Ventilation System
    Naghani, Peyman Ebrahimi
    Zolfaghari, Seyed Alireza
    Maerefat, Mehdi
    Toftum, Jorn
    Hooshmand, Seyed Mohammad
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (02)
  • [37] Experimental and numerical simulation investigation of the deformation characteristics of vertical boreholes under non-uniform horizontal principal stress
    Fang, Xinxin
    Ma, Sijie
    Wang, Yunhong
    Li, Fengling
    GEOMECHANICS AND GEOPHYSICS FOR GEO-ENERGY AND GEO-RESOURCES, 2024, 10 (01)
  • [38] Investigation on non-uniform strains of a 2.5D woven ceramic matrix composite under in-plane tensile stress
    Teng, Xuefeng
    Shi, Duoqi
    Cheng, Zhen
    Jing, Xin
    Lyu, Shuangqi
    Yang, Xiaoguang
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2020, 40 (01) : 36 - 48
  • [39] Experimental investigation of microchannel heat sink performance under non-uniform heat load conditions with different flow configurations
    Shanmugam, Mathiyazhagan
    Maganti, Lakshmi Sirisha
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 203
  • [40] Experimental study on the drag characteristic and non-uniform fillings for wet cooling towers under thermal performance of crosswind conditions
    Zhou, Yang
    Wang, Kun
    Gao, Ming
    Dang, Zhigang
    He, Suoying
    Sun, Fengzhong
    APPLIED THERMAL ENGINEERING, 2018, 140 : 398 - 405