Diffusion tensor MR imaging and fiber tractography: Technical considerations

被引:290
作者
Mukherjee, P. [1 ]
Chung, S. W. [1 ]
Berman, J. I. [1 ]
Hess, C. P. [1 ]
Henry, R. G. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
D O I
10.3174/ajnr.A1052
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This second article of the 2-part review builds on the theoretic background provided by the first article to cover the major technical factors that affect image quality in diffusion imaging, including the acquisition sequence, magnet field strength, gradient amplitude, and slew rate as well as multichannel radio-frequency coils and parallel imaging. The sources of many common diffusion image artifacts are also explored in detail. The emphasis is on optimizing these technical factors for state-of-the-art diffusion-weighted imaging and diffusion tensor imaging (DTI) based on the best available evidence in the literature. An overview of current methods for quantitative analysis of DTI data and fiber tractography in clinical research is also provided.
引用
收藏
页码:843 / 852
页数:10
相关论文
共 79 条
[1]   Periodically rotated overlapping parallel lines with enhanced reconstruction-based diffusion tensor imaging - Comparison with echo planar imoging-based diffusion tensor imaging [J].
Abe, O ;
Mori, H ;
Aoki, S ;
Kunimatsu, A ;
Hayashi, N ;
Masumoto, T ;
Yamada, H ;
Masutani, Y ;
Kabasawa, H ;
Ohtomo, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (05) :654-660
[2]   Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients [J].
Alexander, AL ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1016-1021
[3]   Optimal imaging parameters for fiber-orientation estimation in diffusion MRI [J].
Alexander, DC ;
Barker, GJ .
NEUROIMAGE, 2005, 27 (02) :357-367
[4]   Theoretical analysis of the effects of noise on diffusion tensor imaging [J].
Anderson, AW .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1174-1188
[5]   Utilizing the diffusion-to-noise ratio to optimize magnetic resonance diffusion tensor acquisition strategies for improving measurements of diffusion anisotropy [J].
Armitage, PA ;
Bastin, ME .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1056-1065
[6]   Diffusion tensor imaging using single-shot SENSE-EPI [J].
Bammer, R ;
Auer, M ;
Keeling, SL ;
Augustin, M ;
Stables, LA ;
Prokesch, RW ;
Stollberger, R ;
Moseley, ME ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :128-136
[7]   Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using Sensitivity Encoding (SENSE) [J].
Bammer, R ;
Keeling, SL ;
Augustin, M ;
Pruessmann, KP ;
Wolf, R ;
Stollberger, R ;
Hartung, HP ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :548-554
[8]   A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging [J].
Bastin, ME ;
Armitage, PA ;
Marshall, I .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :773-785
[9]   Anisotropic noise propagation in diffusion tensor MRI sampling schemes [J].
Batchelor, PG ;
Atkinson, D ;
Hill, DLG ;
Calamante, F ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1143-1151
[10]   Probabilistic diffusion tractography with multiple fibre orientations: What can we gain? [J].
Behrens, T. E. J. ;
Berg, H. Johansen ;
Jbabdi, S. ;
Rushworth, M. F. S. ;
Woolrich, M. W. .
NEUROIMAGE, 2007, 34 (01) :144-155