Performance of the frequency domain indices with respect to sleep staging

被引:13
作者
Kuo, Terry B. J. [1 ,2 ,3 ,4 ]
Chen, C. Y. [1 ,2 ]
Hsu, Ya-Chuan [1 ,2 ]
Yang, Cheryl C. H. [1 ,2 ,3 ]
机构
[1] Natl Yang Ming Univ, Inst Brain Sci, Taipei 11221, Taiwan
[2] Natl Yang Ming Univ, Sleep Res Ctr, Taipei 11221, Taiwan
[3] Taipei City Hosp, Dept Educ & Res, Taipei, Taiwan
[4] Natl Cent Univ, Res Ctr Adapt Data Anal, Tao Yuan, Taiwan
关键词
Sleep staging; Frequency domain analysis; Computer scoring; Acceleration; Heart rate variability; SPINDLES;
D O I
10.1016/j.clinph.2011.11.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To compare computerized staging using spectral analyses of various electrophysiological signals with manual sleep staging. Methods: Sleep recordings from 21 normal subjects were scored by an experienced rater and by a dichotomous algorithm. The performance of the spectral indices was assessed by the largest kappa value (LKV). Results: Theta/beta power ratio of the electroencephalogram, high frequency power (8-58 Hz) of the electromyogram (PEMG), mean R-R interval, and total power (0-16 Hz) of the body acceleration (PACCE) had high (>0.5) LKVs when differentiating between waking and sleep. To differentiate sleep with (stage 2 and slow wave sleep) and without (rapid eye movement and stage 1 sleep) spindles, sigma/beta power ratio had high LKVs. PEMG had a medium (>0.25) LKV to separate rapid eye movement from stage 1 sleep whereas delta/beta power ratio had a high LKV to separate stage 2 and slow wave sleep. Conclusion: The frequency components of electroencephalogram perform well in identifying sleep, sleep with spindles, and slow wave sleep. Electromyogram, heart rate, and body acceleration offer high agreement only when differentiating between wakefulness and sleep. Significance: The human-machine agreement is acceptable with spectral parameters, but heart rate and body acceleration still cannot substitute for electroencephalogram. (C) 2011 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1338 / 1345
页数:8
相关论文
共 19 条
[1]   Automatic analysis of single-channel sleep EEG:: Validation in healthy individuals [J].
Berthomier, Christian ;
Drouot, Xavier ;
Herman-Stoieca, Maria ;
Berthomier, Pierre ;
Prado, Jacques ;
Bokar-Thire, Djibril ;
Benoit, Odile ;
Mattout, Jeremie ;
d'Ortho, Marie-Pia .
SLEEP, 2007, 30 (11) :1587-1595
[2]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[3]  
Campbell Ian G, 2009, Curr Protoc Neurosci, VChapter 10, DOI 10.1002/0471142301.ns1002s49
[4]   Sleep spindles: an overview [J].
De Gennaro, L ;
Ferrara, M .
SLEEP MEDICINE REVIEWS, 2003, 7 (05) :423-440
[5]  
Hobson JA, 1969, Public Health Service Publication, V26, P644
[6]  
Iber C, 2007, AASM MANUAL SCORING, DOI DOI 10.1002/EJOC.201200111
[7]   Sleep detection with an accelerometer actigraph: comparisons with polysomnography [J].
Jean-Louis, G ;
Kripke, DF ;
Cole, RJ ;
Assmus, JD ;
Langer, RD .
PHYSIOLOGY & BEHAVIOR, 2001, 72 (1-2) :21-28
[8]   A SIMPLE FORMAT FOR EXCHANGE OF DIGITIZED POLYGRAPHIC RECORDINGS [J].
KEMP, B ;
VARRI, A ;
ROSA, AC ;
NIELSEN, KD ;
GADE, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (05) :391-393
[9]   Changes in sleep patterns in spontaneously hypertensive rats [J].
Kuo, TBJ ;
Shaw, FZ ;
Lai, CJ ;
Lai, CW ;
Yang, CCH .
SLEEP, 2004, 27 (03) :406-412
[10]   CONTINUOUS, ONLINE, REAL-TIME SPECTRAL-ANALYSIS OF SYSTEMIC ARTERIAL-PRESSURE SIGNALS [J].
KUO, TBJ ;
CHAN, SHH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (06) :H2208-H2213