Cold Atmospheric Air Plasma Sterilization against Spores and Other Microorganisms of Clinical Interest

被引:282
作者
Klaempfl, Tobias G. [1 ,3 ]
Isbary, Georg [2 ]
Shimizu, Tetsuji [1 ]
Li, Yang-Fang [1 ]
Zimmermann, Julia L. [1 ]
Stolz, Wilhelm [2 ]
Schlegel, Juergen [3 ]
Morfill, Gregor E. [1 ]
Schmidt, Hans-Ulrich [4 ]
机构
[1] Max Planck Inst Extraterr Phys, Garchirg, Germany
[2] Hosp Munich Schwabing, Dept Dermatol Allergol & Environm Med, Munich, Germany
[3] Tech Univ Munich, Dept Gen Pathol & Pathol Anat, Munich, Germany
[4] Hosp Munich Schwabing, Dept Microbiol, Munich, Germany
关键词
BACILLUS-SUBTILIS; ARGON PLASMA; INACTIVATION; RESISTANCE; SURFACES; HEAT; MICROSCOPY; RADIATION; CONTRAST; BIOFILMS;
D O I
10.1128/AEM.00583-12
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Physical cold atmospheric surface microdischarge (SMD) plasma operating in ambient air has promising properties for the sterilization of sensitive medical devices where conventional methods are not applicable. Furthermore, SMD plasma could revolutionize the field of disinfection at health care facilities. The antimicrobial effects on Gram-negative and Gram-positive bacteria of clinical relevance, as well as the fungus Candida albicans, were tested. Thirty seconds of plasma treatment led to a 4 to 6 logic, CFU reduction on agar plates. C. albicans was the hardest to inactivate. The sterilizing effect on standard bioindicators (bacterial endospores) was evaluated on dry test specimens that were wrapped in Tyvek coupons. The experimental D-23 degrees C values for Bacillus subtilis, Bacillus pumilus, Bacillus atrophaeus, and Geobacillus stearothermophilus were determined as 0.3 min, 0.5 min, 0.6 min, and 0.9 min, respectively. These decimal reduction times (D values) are distinctly lower than D values obtained with other reference methods. Importantly, the high inactivation rate was independent of the material of the test specimen. Possible inactivation mechanisms for relevant microorganisms are briefly discussed, emphasizing the important role of neutral reactive plasma species and pointing to recent diagnostic methods that will contribute to a better understanding of the strong biocidal effect of SMD air plasma,
引用
收藏
页码:5077 / 5082
页数:6
相关论文
共 50 条
[1]   Ambient and biochemical effect monitoring of workers exposed to ethylene oxide [J].
Angerer, J ;
Bader, M ;
Kramer, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1998, 71 (01) :14-18
[2]  
[Anonymous], NY TIMES
[3]   Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[4]  
Beuth Verlag GmbH, 2010, 149372009 DIN EN ISO
[5]  
Beuth Verlag GmbH, 2009, 1173712006AC2009 DIN
[6]  
Beuth Verlag GmbH, 2006, 184722006 DIN EN ISO
[7]  
BIELSKI BHJ, 1983, J BIOL CHEM, V258, P4759
[8]  
CDC, 2007, PUBL HLTH REP
[9]   Treatment with oxidizing agents damages the inner membrane of spores of Bacillus subtilis and sensitizes spores to subsequent stress [J].
Cortezzo, DE ;
Koziol-Dube, K ;
Setlow, B ;
Setlow, P .
JOURNAL OF APPLIED MICROBIOLOGY, 2004, 97 (04) :838-852
[10]   The impact of antimicrobial resistance on health and economic outcomes [J].
Cosgrove, SE ;
Carmeli, Y .
CLINICAL INFECTIOUS DISEASES, 2003, 36 (11) :1433-1437