Comparing Proton to Photon Radiotherapy Plans: UK Consensus Guidance for Reporting Under Uncertainty for Clinical Trials

被引:22
作者
Lowe, M. [1 ,2 ]
Gosling, A. [3 ]
Nicholas, O. [4 ,5 ,6 ]
Underwood, T. [2 ]
Miles, E. [7 ]
Chang, Y-C [8 ]
Amos, R. A. [9 ]
Burnet, N. G. [2 ,10 ]
Clark, C. H. [7 ]
Patel, I [1 ,2 ]
Tsang, Y. [7 ]
Sisson, N. [11 ]
Gulliford, S. [3 ,12 ]
机构
[1] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester M20 4BX, Lancs, England
[2] Univ Manchester, Sch Med Sci, Div Canc Sci, Manchester, Lancs, England
[3] Univ Coll London Hosp NHS Fdn Trust, Dept Radiotherapy Phys, London, England
[4] Swansea Bay NHS Trust, South West Wales Canc Ctr, Swansea, W Glam, Wales
[5] Swansea Univ, Med Sch, Swansea, W Glam, Wales
[6] Velindre Canc Ctr, Natl Radiotherapy Trials Qual Assurance Grp, Cardiff, Wales
[7] Mt Vernon Hosp, Natl Radiotherapy Trials Qual Assurance Grp, Northwood, Middx, England
[8] Univ Coll London Hosp NHS Fdn Trust, Dept Radiotherapy, London, England
[9] UCL, Dept Med Phys & Biomed Engn, Proton & Adv Radiotherapy Grp, London, England
[10] Christie NHS Fdn Trust, Manchester, Lancs, England
[11] Clatterbridge Canc Ctr NHS Fdn Trust, Natl Radiotherapy Trials Qual Assurance Grp, Wirral, Merseyside, England
[12] UCL, Dept Med Phys & Biomed Engn, London, England
基金
英国医学研究理事会; 英国工程与自然科学研究理事会;
关键词
Clinical trials; guidelines; proton therapy; proton therapy comparison; uncertainty; ROBUST OPTIMIZATION; RANGE UNCERTAINTIES; THERAPY; MOTION; HEAD;
D O I
10.1016/j.clon.2020.03.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In the UK, the recent introduction of high-energy proton beam therapy into national clinical practice provides an opportunity for new clinical trials, particularly those comparing proton and photon treatments. However, comparing these different modalities can present many challenges. Although protons may confer an advantage in terms of reduced normal tissue dose, they can also be more sensitive to uncertainty. Uncertainty analysis is fundamental in ensuring that proton plans are both safe and effective in the event of unavoidable discrepancies, such as variations in patient setup and proton beam range. Methods of evaluating and mitigating the effect of these uncertainties can differ from those approaches established for photon therapy treatments, such as the use of expansion margins to assure safety. These differences should be considered when comparing protons and photons. An overview of the effect of uncertainties on proton plans is presented together with an introduction to some of the concepts and terms that should become familiar to those involved in proton therapy trials. This report aims to provide guidance for those engaged in UK clinical trials comparing protons and photons. This guidance is intended to take a pragmatic approach considering the tools that are available to practising centres and represents a consensus across multidisciplinary groups involved in proton therapy in the UK. (C) 2020 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:459 / 466
页数:8
相关论文
共 22 条
[1]   Is it necessary to plan with safety margins for actively scanned proton therapy? [J].
Albertini, F. ;
Hug, E. B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) :4399-4413
[2]   Proton Beam Therapy - the Challenges of Delivering High-quality Evidence of Clinical Benefit [J].
Amos, R. ;
Bulbeck, H. ;
Burnet, N. G. ;
Crellin, A. ;
Eaton, D. ;
Evans, P. ;
Hall, E. ;
Hawkins, M. A. ;
Kirkby, K. J. ;
Mackay, R. ;
Sebag-Montefiore, D. ;
Sharma, R. .
CLINICAL ONCOLOGY, 2018, 30 (05) :280-284
[3]  
[Anonymous], 2016, Journal of the International Commission on Radiation Units and Measurements, V10, DOI DOI 10.1093/JICRU/10.1.REPORT83
[4]   Robust optimization to reduce the impact of biological effect variation from physical uncertainties in intensity-modulated proton therapy [J].
Bai, Xuemin ;
Lim, Gino ;
Grosshans, David ;
Mohan, Radhe ;
Cao, Wenhua .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (02)
[5]   Motion in radiotherapy: particle therapy [J].
Bert, C. ;
Durante, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :R113-R114
[6]   The Road Map for National Health Service Proton Beam Therapy [J].
Crellin, A. .
CLINICAL ONCOLOGY, 2018, 30 (05) :277-279
[7]   Including anatomical variations in robust optimization for head and neck proton therapy can reduce the need of adaptation [J].
Cubillos-Mesias, Macarena ;
Troost, Esther G. C. ;
Lohaus, Fabian ;
Agolli, Linda ;
Rehm, Maximilian ;
Richter, Christian ;
Stuetzer, Kristin .
RADIOTHERAPY AND ONCOLOGY, 2019, 131 :127-134
[8]   A critical evaluation of worst case optimization methods for robust intensity-modulated proton therapy planning [J].
Fredriksson, Albin ;
Bokrantz, Rasmus .
MEDICAL PHYSICS, 2014, 41 (08) :48-58
[9]   Minimax optimization for handling range and setup uncertainties in proton therapy [J].
Fredriksson, Albin ;
Forsgren, Anders ;
Hardemark, Bjorn .
MEDICAL PHYSICS, 2011, 38 (03) :1672-1684
[10]  
International Commission on Radiation Units and Measure- ments, 1999, 62 ICRU, DOI [10.1093/jicru/os32.1.Report62, DOI 10.1093/JICRU/OS32.1.REPORT62]