Three-dimensional ultrasound-guided breast biopsy system

被引:0
|
作者
Smith, WL
Surry, K
Campbell, L
Mills, G
Downey, D
Fenster, A
机构
[1] Imaging Research Laboratories, John P. Robarts Research Institute, Dept. of Medical Biophysics University of Western ON University of Western Ontario, London, ON
[2] Imaging Research Laboratories, John P. Robarts Research Institute, Dept. of Medical Biophysics University of Western Ontario University of Western Ontario, London, ON
[3] Dept. of Radiology, London Health Sciences Centre, London, ON
关键词
D O I
10.1117/12.428046
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We introduce a mechanically constrained, three-dimensional ultrasound-guided core-needle breast biopsy device. With modest breast compression, three-dimensional ultrasound scans localize suspicious masses. A biopsy needle is mechanically guided into position for firing into the sampling region. The needle is parallel to the transducer, allowing real-time guidance during needle insertion. Lesion sampling is verified by another ultrasound image after firing. Two procedures quantified targeting accuracy of this apparatus. First, we biopsied eleven breast phantoms containing 123 embedded, cylindrical lesions constructed from PVA-C (poly(vinyl alcohol) cryogel) with diameters ranging from 1.6 to 15.9mm. Identification of the colored lesion in the biopsy sample and analysis of the post-biopsy US images provided a model for the success rates. Using this, we predict that our apparatus will require six passes to biopsy a 3.0mm lesion with 99% confidence. For the second experiment, agar phantoms were embedded with four rows of 0.8mm stainless steel beads. A 14-guage needle was inserted to each bead position seen in a 3D ultrasound scan and the tip position was compared to the pre-insertion bead position. The inter-observer standard errors of measurement were less than 0.15 and 0.28mm for the bead and needle tip positions, respectively. The off-axis three-dimensional 95% confidence intervals were determined to have widths between 0.43 and 1.71mm, depending on direction and bead position.
引用
收藏
页码:134 / 143
页数:10
相关论文
共 50 条
  • [31] Needle choice for ultrasound-guided core breast biopsy
    Mallo, R
    Diaz, M
    Garcia-Tejedor, JL
    Alvarez, P
    Paz, SF
    Vieito, JM
    RADIOLOGY, 2001, 221 : 190 - 190
  • [32] 3D ultrasound-guided breast biopsy: System configuration and evaluation
    Smith, W
    Surry, K
    Downey, D
    Fenster, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1198 - 1198
  • [33] A mechatronic guidance system for positron emission mammography and ultrasound-guided breast biopsy
    Park, Claire K.
    Bax, Jeffrey
    Gardi, Lori
    Fenster, Aaron
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [34] Complete extirpation of benign breast lesions with an ultrasound-guided vacuum biopsy system
    Krainick-Strobel, U.
    Huber, B.
    Majer, I.
    Bergmann, A.
    Gall, C.
    Gruber, I.
    Hoffmann, J.
    Paepke, S.
    Peisker, U.
    Walz-Mattmueller, R.
    Siegmann, K.
    Wallwiener, D.
    Hahn, M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 29 (03) : 342 - 346
  • [35] ULTRASOUND-GUIDED RENAL-ALLOGRAFT BIOPSY WITH THE BIOPSY SYSTEM
    UBHI, CS
    IRVING, HC
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (714): : 626 - 626
  • [36] The use of three-dimensional ultrasound imaging in breast biopsy and prostate therapy
    Fenster, A
    Surry, K
    Smith, W
    Downey, DB
    MEASUREMENT, 2004, 36 (3-4) : 245 - 256
  • [37] Evaluation of a 3D ultrasound-guided breast biopsy apparatus by comparison to free-hand ultrasound-guided biopsy
    Surry, KJ
    Smith, WL
    Mills, GR
    Downey, DB
    Fenster, A
    RADIOLOGY, 2001, 221 : 554 - 554
  • [38] Novel Three-Dimensional Printed Simulators for Ultrasound-Guided Prenatal Diagnostic Procedures
    Keller, Nathan A.
    Neuwirth, Allison E.
    Jackson, Frank I.
    Kouba, Insaf
    Muscat, Jolene
    Bracero, Luis A.
    Blitz, Matthew J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2025,
  • [39] Three-dimensional endoluminal ultrasound-guided interstitial brachytherapy in patients with anal cancer
    Christensen, A. F.
    Nielsen, M. Bachmann
    Engelholm, S. A.
    ACTA RADIOLOGICA, 2008, 49 (02) : 132 - 137
  • [40] Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
    Abayazid, Momen
    Moreira, Pedro
    Shahriari, Navid
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (01) : 145 - 150