Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty

被引:159
|
作者
Whaley, AL [1 ]
Berry, DJ [1 ]
Harmsen, WS [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped, Rochester, MN 55905 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 2001年 / 83A卷 / 09期
关键词
D O I
10.2106/00004623-200109000-00010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Extra-large uncemented components provide several advantages for acetabular revision, but limited information is available on the results of their use. The purpose of this study was to evaluate, at a minimum of five years, the results associated with the use of an extra-large uncemented porous-coated component for acetabular revision in the presence of bone loss. Methods: Eighty-nine extra-large uncemented hemispherical acetabular components were used for revision after aseptic failure of a total hip arthroplasty in forty-six men and forty-three women (mean age at revision, fifty-nine years; range, thirty to eighty-three years). The revision implant (a Harris-Galante-I or II cup fixed with screws) had an outside diameter of greater than or equal to 66 mm in men and greater than or equal to 62 mm in women. Seventy-nine patients had a segmental or combined segmental and cavitary acetabular bone deficiency before the revision. Particulate bone graft was used in fifty-four hips and bulk bone graft, in nine. Results: One patient died with the acetabular component intact and two patients were lost to follow-up within five years after the operation. At the time of the last follow-up, four acetabular components had been removed or revised again (two for aseptic loosening). All of the remaining patients were followed clinically for at least five years (mean, 7.2 years; range, 5.0 to 11.3 years). In the hips that were not revised again, only two sockets had definite radiographic evidence of loosening. All four of the sockets that loosened were in hips that had had combined cavitary and segmental bone loss preoperatively. In the hips that were not revised again, the mean modified Harris hip score increased from 56 points preoperatively to 83 points at the time of the most recent follow-up. The most frequent complication, dislocation of the hip, occurred in eleven patients. The probability of survival of the acetabular component at eight years was 93% (95% confidence interval, 85% to 100%) with removal for any reason as the end point, 98% (95% confidence interval, 92% to 100%) with revision for aseptic loosening as the end point, and 95% (95% confidence interval, 88% to 100%) with radiographic evidence of loosening or revision for aseptic loosening as the end point. Conclusions: This study demonstrates that extra-large uncemented components used for acetabular revision in the presence of bone loss perform very well and have a low rate of aseptic loosening at the time of intermediateterm follow-up.
引用
收藏
页码:1352 / 1357
页数:6
相关论文
共 50 条
  • [31] ACETABULAR PREPARATION IN CEMENTLESS REVISION TOTAL HIP-ARTHROPLASTY
    MCGANN, WA
    WELCH, RB
    PICETTI, GD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1988, (235) : 35 - 46
  • [32] Revision total hip arthroplasty with an uncemented primary stem in 79 patients
    Fritz Thorey
    Matthias Lerch
    Heike Kiel
    Gabriela von Lewinski
    Christina Stukenborg-Colsman
    Henning Windhagen
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 673 - 678
  • [33] Management of massive acetabular defects in revision total hip arthroplasty
    Dennis, DA
    JOURNAL OF ARTHROPLASTY, 2003, 18 (03): : 121 - 125
  • [34] Management of Acetabular Bone Loss in Revision Total Hip Arthroplasty
    Deirmengian, Gregory K.
    Zmistowski, Benjamin
    O'Neil, Joseph T.
    Hozack, William J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (19): : 1842 - 1852
  • [35] Revision total hip arthroplasty with an uncemented primary stem in 79 patients
    Thorey, Fritz
    Lerch, Matthias
    Kiel, Heike
    von Lewinski, Gabriela
    Stukenborg-Colsman, Christina
    Windhagen, Henning
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (07) : 673 - 678
  • [36] Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty - Clinical and radiological results of 60 hips
    Unger, AS
    Lewis, RJ
    Gruen, T
    JOURNAL OF ARTHROPLASTY, 2005, 20 (08): : 1002 - 1009
  • [37] Revision total knee arthroplasty with cemented components and uncemented intramedullary stems
    Shannon, BD
    Klassen, JF
    Rand, JA
    Berry, DJ
    Trousdale, RT
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 27 - 32
  • [38] Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: a systematic review and meta-analysis on 1218 patients
    Broekhuis, Demien
    Tordoir, Rutger
    Vallinga, Zoe
    Schoones, Jan
    Pijls, Bart
    Nelissen, Rob
    EFORT OPEN REVIEWS, 2023, 8 (07) : 522 - 531
  • [39] UNCEMENTED VERSUS HYBRID TOTAL HIP ARTHROPLASTY: REVISION RATE, REVISION RISK FACTORS, AND REVISION CAUSE
    Cimic, Mislav
    Cimic, Kristina
    Bohacek, Ivan
    Plecko, Mihovil
    Delimar, Domagoj
    ACTA CLINICA CROATICA, 2023, 62 (04)
  • [40] Fixation, Survival, and Dislocation of Jumbo Acetabular Components in Revision Hip Arthroplasty
    Lachiewicz, Paul E.
    Soileau, Elizabeth S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (06): : 543 - 548