Changes in wavefront aberration with pharmaceutical dilating agents

被引:0
作者
Tuan, KA [1 ]
Somani, S [1 ]
Chernyak, DA [1 ]
机构
[1] VISX Inc, Santa Clara, CA USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: Finding the best way to capture the wavefronts of small pupils for refractive surgery has become a more pressing issue as the general population ages. This study explores whether pharmaceutical dilation impacts wavefront measurement and pupil centroid. METHODS: Baseline measurements were performed on 32 eyes using the VISX WaveScan Wavefront system. Pupils were dark adapted. One drop of 0.05% tropicamide was placed in each eye, and wavefront measurements were conducted at 10, 20, and 30 minutes. One drop each of 0.5% tropicamide and 2.5% phenylephrine were administered after the measurements. Wavefronts were captured again 30 minutes after the last eye drop. All patients returned for repeated procedures. Wavefront analysis was performed using the same pupillary area as the smallest capture from the same visit. Pupil, center shift was taken into account. RESULTS: Mean patient age was 40 12 years (range: 20 to 59 years). Mean dark-adapted pupil was 6.40 +/- 1.17 mm. Pupil centers shifted randomly after pharmacological dilation compared to the dark-adapted condition. Pupil centers of 45% of the population shifted by >= 0.2 mm. Repeatability coefficients were established for the wavefront measurements. After controlling for pupil diameter and pupil center, total high order aberrations root-mean-square (RMS) had changed significantly in 18% of the population. The diluted tropicamide formula, which caused less dilation effect, also induced less high order aberration RMS change. CONCLUSIONS: Pharmaceutical dilation agents cause random shifts of the pupil centroid from the dark-adapted pupil condition and could induce changes in wavefront measurements. Caution is required when resorting to dilation to obtain a wavefront measurement of smaller pupils.
引用
收藏
页码:S530 / S534
页数:5
相关论文
共 8 条
[1]   Positioning tolerances for phase plates compensating aberrations of the human eye [J].
Bará, S ;
Mancebo, T ;
Moreno-Barriuso, E .
APPLIED OPTICS, 2000, 39 (19) :3413-3420
[2]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[3]  
Carkeet A, 2003, J REFRACT SURG, V19, P316
[4]  
Chernyak DA, 2005, J REFRACT SURG, V21, P463
[5]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[6]  
PAQUIN M, 2002, OPTOMETRY VISION SCI, V5, P285
[8]  
Yang YB, 2002, INVEST OPHTH VIS SCI, V43, P2508