Reliability and repeatability of the motor and sensory examination of the International Standards for Neurological Classification of Spinal Cord Injury

被引:100
作者
Marino, Ralph J. [1 ]
Jones, Linda [2 ]
Kirshblum, Steven [3 ]
Tal, Joseph [4 ]
Dasgupta, Abhiijit [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Philadelphia, PA 19107 USA
[2] Proneuron Biotechnol, Los Angeles, CA USA
[3] Kessler Inst Rehabil, W Orange, NJ USA
[4] TechnoStat Ltd, Kefar Sava, Israel
关键词
spinal cord injuries; paraplegia; tetraplegia; neurological examination; motor; sensory; outcomes; reliability;
D O I
10.1080/10790268.2008.11760707
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To determine the reliability and repeatability of the motor and sensory examination of the International Standards for Classification of Spinal Cord Injury (SCI) in trained examiners. Participants/Methods: Sixteen examiners (8 physicians, 8 physical therapists) with clinical SCI experience and 16 patients participated in a reliability study in preparation for a clinical trial involving individuals with acute SCI. After a training session on the standards, each examiner evaluated 3 patients for motor, light touch (LT), and pin prick (PP). The following day, 15 examiners reevaluated one patient. Inter-rater reliability was determined using intraclass correlation coefficients (1-way, random effects model). Intra-rater reliability was determined using a 2-way random effects model. Repeatability was determined using the method of Bland and Altman. Results: Patients were classified as complete tetraplegia (n = 5), incomplete tetraplegia (n = 5), complete paraplegia (n = 5), and incomplete paraplegia (n = 1). Overall, inter-rater reliability was high: motor = 0.97, LT = 0.96, PP = 0.88. Repeatability values were small in patients with complete SCI (motor < 2 points, sensory < 7 points) but large for patients with incomplete SCI. Intra-rater reliability values were >= 0.98 for patients with complete SCI. Conclusions: The summed scores for motor, LT, and PP in subjects with complete SCI have high inter-rater reliability and small repeatability values. These measures are appropriately reliable for use in clinical trials involving serial neurological examinations with multiple examiners. Further research in subjects with incomplete SCI is needed to determine whether repeatability is acceptably small.
引用
收藏
页码:166 / 170
页数:5
相关论文
共 16 条
  • [1] *AM SPIN INJ ASS, 1996, INT STAND NEUR CLASS
  • [2] American Spinal Injury Association, 1992, INT STAND NEUR FUNCT
  • [3] American Spinal Injury Association, 2002, International Standards for Neurological Classification of Spinal Cord Injury
  • [4] [Anonymous], 2000, International Standards for Neurological Classification of Spinal Cord Injury
  • [5] [Anonymous], 2003, REF MAN INT STAND NE
  • [6] Smallest real difference, a link between reproducibility and responsiveness
    Beckerman, H
    Roebroeck, ME
    Lankhorst, GJ
    Becher, JG
    Bezemer, PD
    Verbeek, ALM
    [J]. QUALITY OF LIFE RESEARCH, 2001, 10 (07) : 571 - 578
  • [7] Measurement error
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 312 (7047) : 1654 - 1654
  • [8] Cohen ME, 1994, REFERENCE MANUAL INT, P59
  • [9] Deyo RA, 1991, CONTROLLED CLIN TRIA, V12, P142
  • [10] HINDERER SR, 2005, PHYS MED REHABILITAT, P1139