Different Neoatherosclerosis Patterns in Drug-Eluting- and Bare-Metal Stent Restenosis - Optical Coherence Tomography Study -

被引:25
作者
Nakamura, Daisuke [1 ]
Yasumura, Keisuke [1 ]
Nakamura, Hitoshi [1 ]
Matsuhiro, Yutaka [1 ]
Yasumoto, Koji [1 ]
Tanaka, Akihiro [1 ]
Matsunaga-Lee, Yasuharu [1 ]
Yano, Masamichi [1 ]
Yamato, Masaki [1 ]
Egami, Yasuyuki [1 ]
Shutta, Ryu [1 ]
Sakata, Yasushi [2 ]
Tanouchi, Jun [1 ]
Nishino, Masami [1 ]
机构
[1] Osaka Rosai Hosp, Div Cardiol, 1179-3 Nagasone Cho, Sakai, Osaka 5918025, Japan
[2] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Suita, Osaka, Japan
关键词
In-stent restenosis; Neoatherosclerosis; Optical coherence tomography; CORONARY-ARTERY; PLAQUE; MECHANISMS; THROMBOSIS; INTERVENTION; IMPACT;
D O I
10.1253/circj.CJ-18-0701
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There are few reports about the differences between drug-eluting stents (DES) and bare metal stents (BMS) in neoatherosclerosis associated with in-stent restenosis (ISR), so we compared the frequency and characteristics of neoatherosclerosis with ISR evaluated by optical coherence tomography (OCT) in the present study. Methods and Results: Between March 2009 and November 2016, 98 consecutive patients with ISR who underwent diagnostic OCT were enrolled: 34 patients had a BMS, 34 had a 1st-generation DES, and 30 had a 2nd-generation DES. Neoatherosclerosis was defined as a lipid neointima (including a thin-cap fibroatheroma [TCFA] neointima, defined as a fibroatheroma with a fibrous cap <65 mu m) or calcified neointima. As a result, lipid neointima, TCFA neointima and calcified neointima were detected in 39.8%, 14.3%, and 5.1%, respectively, of all patients. The frequency of neoatherosclerosis was significantly greater with DES than BMS (48.4% vs. 23.5%, P=0.018). The minimum fibrous cap thickness was significantly thicker with DES than BMS (110.3 +/- 41.1 mu m vs. 62.5 +/- 17.1 mu m, P<0.001). In addition, longitudinal extension of neoatherosclerosis in the stented segment was less with DES than BMS (20.2 +/- 15.1% vs. 71.8 +/- 27.1%, respectively, P=0.001). Conclusions: OCT imaging demonstrated that neoatherosclerosis with ISR was more frequent with DES than BMS and its pattern exhibited a more focal and thick fibrous cap as compared with BMS.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 50 条
  • [21] Neoatherosclerosis assessed with optical coherence tomography in restenotic bare metal and first- and second-generation drug-eluting stents
    Lei Song
    Gary S. Mintz
    Dong Yin
    Myong Hwa Yamamoto
    Chee Yang Chin
    Mitsuaki Matsumura
    Khady Fall
    Ajay J. Kirtane
    Manish A. Parikh
    Jeffrey W. Moses
    Ziad A. Ali
    Richard A. Shlofmitz
    Akiko Maehara
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1115 - 1124
  • [23] Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent
    Heng Ge
    Qing Zhang
    Wei Zhou
    Qing He
    Zhi-hua Han
    Ben He
    Journal of Zhejiang University SCIENCE B, 2010, 11 : 553 - 560
  • [24] Impact of Different Re-stenting Strategies on Expansion of a Drug-Eluting Stent Implanted to Treat Bare-Metal Stent Restenosis
    Kalinczuk, Lukasz
    Demkow, Marcin
    Mintz, Gary S.
    Cedro, Krzysztof
    Debski, Artur
    Ciszewski, Michal
    Ciszewski, Andrzej
    Kruk, Mariusz
    Karcz, Maciej
    Warminski, Grzegorz
    Pregowski, Jerzy
    Chmielak, Zbigniew
    Witkowski, Adam
    Lubiszewska, Barbara
    Ruzyllo, Witold
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (04) : 531 - 537
  • [25] A Randomized Comparison of Drug-Eluting Balloon Versus Everolimus-Eluting Stent in Patients With Bare-Metal Stent-In-Stent Restenosis
    Alfonso, Fernando
    Jose Perez-Vizcayno, Maria
    Cardenas, Alberto
    Garcia del Blanco, Bruno
    Seidelberger, Bernhard
    Iniguez, Andres
    Gomez-Recio, Manuel
    Masotti, Monica
    Teresa Velazquez, M.
    Sanchis, Juan
    Garcia-Touchard, Arturo
    Zueco, Javier
    Bethencourt, Armando
    Melgares, Rafael
    Cequier, Angel
    Dominguez, Antonio
    Mainar, Vicente
    Lopez-Minguez, Jose R.
    Moreu, Jose
    Marti, Vicens
    Moreno, Raul
    Jimenez-Quevedo, Pilar
    Gonzalo, Nieves
    Fernandez, Cristina
    Macaya, Carlos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (14) : 1378 - 1386
  • [26] Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents
    Guagliumi, Giulio
    Musumeci, Giuseppe
    Sirbu, Vasile
    Bezerra, Hiram G.
    Suzuki, Nobuaki
    Fiocca, Luigi
    Matiashvili, Aleksandre
    Lortkipanidze, Nikoloz
    Trivisonno, Antonio
    Valsecchi, Orazio
    Biondi-Zoccai, Giuseppe
    Costa, Marco A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) : 531 - 539
  • [27] Optical coherence tomography patterns of stent restenosis
    Gonzalo, Nieves
    Serruys, Patrick W.
    Okamura, Takaynki
    van Beusekom, Heleen M.
    Garcia-Garcia, Hector M.
    van Soest, Gijs
    van der Giessen, Wim
    Regar, Evelyn
    AMERICAN HEART JOURNAL, 2009, 158 (02) : 284 - 293
  • [28] Optical coherence tomography characteristics of in-stent restenosis after drug-eluting stent implantation: a novel classification and its clinical significance
    Yamamoto, Wataru
    Fujii, Kenichi
    Otsuji, Satoru
    Takiuchi, Shin
    Kakishita, Mikio
    Ibuki, Motoaki
    Hasegawa, Katsuyuki
    Ishibuchi, Kasumi
    Tamaru, Hiroto
    Yasuda, Shingo
    Ishii, Rui
    Nakabayashi, Sho
    Kusumoto, Hirofumi
    Higashino, Yorihiko
    HEART AND VESSELS, 2020, 35 (01) : 38 - 45
  • [29] Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study
    Mahmoud Sabbah
    Kazushige Kadota
    Azza El-Eraky
    Hanan M. Kamal
    Ahmed-Tageldien Abdellah
    Ahmed El Hawary
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1463 - 1472
  • [30] The effect of sex differences on neointimal characteristics of in-stent restenosis in drug-eluting stents: An optical coherence tomography study
    Yuan, Xiaohang
    Jiang, Mengting
    Feng, Huanhuan
    Han, Yan
    Zhang, Xi
    Chen, Yundai
    Gao, Lei
    HELIYON, 2023, 9 (08)