Space-Time-Frequency Multi-Sensor Analysis for Motor Cortex Localization Using Magnetoencephalography

被引:3
作者
Auboiroux, Vincent [1 ]
Larzabal, Christelle [1 ]
Langar, Lilia [2 ]
Rohu, Victor [1 ]
Mishchenko, Ales [1 ]
Arizumi, Nana [1 ]
Labyt, Etienne [1 ]
Benabid, Alim-Louis [1 ]
Aksenova, Tetiana [1 ]
机构
[1] Univ Grenoble Alpes, CEA, LETI, CLINATEC, MINATEC Campus, F-38000 Grenoble, France
[2] CHU Grenoble Alpes, CLINATEC, F-38000 Grenoble, France
关键词
magnetoencephalography; cortex; source imaging; localization; time-frequency; multi-sensor; linear regression; coefficient of determination; HEAD MODEL; MEG; OSCILLATIONS; BRAIN; EEG; RECOGNITION; EPILEPSY; SENSOR; HZ;
D O I
10.3390/s20092706
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Brain source imaging and time frequency mapping (TFM) are commonly used in magneto/electro encephalography (M/EEG) imaging. However, these methods suffer from important limitations. Source imaging is based on an ill-posed inverse problem leading to instability of source localization solutions, has a limited capacity to localize high frequency oscillations and loses its robustness for induced responses (ill-defined trigger). The drawback of TFM is that it involves independent analysis of signals from a number of frequency bands, and from co-localized sensors. In the present article, a regression-based multi-sensor space-time-frequency analysis (MSA) approach, which integrates co-localized sensors and/or multi-frequency information, is proposed. To estimate task-specific brain activations, MSA uses cross-validated, shifted, multiple Pearson correlation, calculated from the time-frequency transformed brain signal and the binary signal of stimuli. The results are projected from the sensor space onto the cortical surface. To assess MSA performance, the proposed method was compared to the weighted minimum norm estimate (wMNE) source imaging method, in terms of spatial selectivity and robustness against an ill-defined trigger. Magnetoencephalography (MEG) recordings were performed in fourteen subjects during two motor tasks: finger tapping and elbow flexion/extension. In particular, our results show that the MSA approach provides good localization performance when compared to wMNE and statistically significant improvement of robustness against ill-defined trigger.
引用
收藏
页数:16
相关论文
共 41 条
[1]   Approximate is better than "exact" for interval estimation of binomial proportions [J].
Agresti, A ;
Coull, BA .
AMERICAN STATISTICIAN, 1998, 52 (02) :119-126
[2]   ELAN: A Software Package for Analysis and Visualization of MEG, EEG, and LFP Signals [J].
Aguera, Pierre-Emmanuel ;
Jerbi, Karim ;
Caclin, Anne ;
Bertrand, Olivier .
COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2011, 2011
[3]  
[Anonymous], 1977, SOLUTIONS ILL POSED
[4]  
[Anonymous], 1968, P 1968 23 ACM NATL C
[5]  
[Anonymous], 1998, APPL REGRESSION ANAL
[6]  
[Anonymous], 2009, NeuroImage, DOI [10.1016/S1053-8119(09)70884-5, DOI 10.1016/S1053-8119(09)70884-5, 10.1016/S1053-8119]
[7]   Magnetoencephalography for brain electrophysiology and imaging [J].
Baillet, Sylvain .
NATURE NEUROSCIENCE, 2017, 20 (03) :327-339
[8]   EEG extended source localization: Tensor-based vs. conventional methods [J].
Becker, H. ;
Albera, L. ;
Comon, P. ;
Haardt, M. ;
Birot, G. ;
Wendling, F. ;
Gavaret, M. ;
Benar, C. G. ;
Merlet, I. .
NEUROIMAGE, 2014, 96 :143-157
[9]   An exoskeleton controlled by an epidural wireless brain-machine interface in a tetraplegic patient: a proof-of-concept demonstration [J].
Benabid, Alim Louis ;
Costecalde, Thomas ;
Eliseyev, Andrey ;
Charvet, Guillaume ;
Verney, Alexandre ;
Karakas, Serpil ;
Foerster, Michael ;
Lambert, Aurelien ;
Moriniere, Boris ;
Abroug, Neil ;
Schaeffer, Marie-Caroline ;
Moly, Alexandre ;
Sauter-Starace, Fabien ;
Ratel, David ;
Moro, Cecile ;
Torres-Martinez, Napoleon ;
Langar, Lilia ;
Oddoux, Manuela ;
Polosan, Mircea ;
Pezzani, Stephane ;
Auboiroux, Vincent ;
Aksenova, Tetiana ;
Mestais, Corinne ;
Chabardes, Stephan .
LANCET NEUROLOGY, 2019, 18 (12) :1112-1122
[10]   American Clinical Magnetoencephalography Society Clinical Practice Guideline 2: Presurgical Functional Brain Mapping Using Magnetic Evoked Fields [J].
Burgess, Richard C. ;
Funke, Michael E. ;
Bowyer, Susan M. ;
Lewine, Jeffrey D. ;
Kirsch, Heidi E. ;
Bagic, Anto I. .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2011, 28 (04) :355-361