Quantitative pharmacokinetic analysis of prostate cancer DCE-MRI at 3 T: comparison of two arterial input functions on cancer detection with digitized whole mount histopathological validation

被引:24
作者
Fennessy, Fiona M. [1 ,2 ]
Fedorov, Andriy [1 ]
Penzkofer, Tobias [1 ,3 ]
Kim, Kyung Won [2 ]
Hirsch, Michelle S. [4 ]
Vangel, Mark G. [5 ]
Masry, Paul [4 ]
Flood, Trevor A. [4 ]
Chang, Ming-Ching [6 ]
Tempany, Clare M. [1 ]
Mulkern, Robert V. [7 ]
Gupta, Sandeep N. [6 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Dana Farber Canc Inst, Dept Radiol, Boston, MA 02115 USA
[3] RWTH Aachen Univ Hosp, Dept Radiol, Aachen, Germany
[4] Brigham & Womens Hosp, Dept Pathol, Boston, MA 02115 USA
[5] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[6] Gen Elect Global Res, Niskayuna, NY 12309 USA
[7] Childrens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
Prostate cancer; Dynamic contrast enhancement; Arterial input function; Pharmacokinetic analysis; CONTRAST-ENHANCED MRI; MULTIPARAMETRIC MRI; PATHOLOGICAL STAGE; BREAST-CANCER; TUMOR VOLUME; PERFUSION; PARAMETERS; REPRODUCIBILITY; AGGRESSIVENESS; INJECTION;
D O I
10.1016/j.mri.2015.02.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate pharmacokinetic (PK) modeling of dynamic contrast enhanced MRI (DCE-MRI) in prostate cancer (PCa) requires knowledge of the concentration time course of the contrast agent in the feeding vasculature, the so-called arterial input function (AIF). The purpose of this study was to compare AIF choice in differentiating peripheral zone PCa from non-neoplastic prostatic tissue (NNPT), using PK analysis of high temporal resolution prostate DCE-MRI data and whole-mount pathology (WMP) validation. This prospective study was performed in 30 patients who underwent multiparametric endorectal prostate MRI at 3.0 T and WMP validation. PCa foci were annotated on WMP slides and MR images using 3D Slicer. Foci >= 0.5 cm(3) were contoured as tumor regions of interest (TROIs) on subtraction DCE (early-arterial pre-contrast) images. PK analyses of TROI and NNPT data were performed using automatic AIF (aAlF) and model AIF (mAIF) methods. A paired t-test compared mean and 90th percentile (p90) PK parameters obtained with the two AIF approaches. Receiver operating characteristic (ROC) analysis determined diagnostic accuracy (DA) of PK parameters. Logistic regression determined correlation between PK parameters and histopathology. Mean TROI and NNPT PK parameters were higher using aAIF vs. mAIF (p < 0.05). There was no significant difference in DA between AIF methods: highest for p90 volume transfer constant (K-trans) (aAlF differences in the area under the ROC curve (Az) = 0.827; mAIF Az = 0.93). Tumor cell density correlated with aAIF Km's (p = 0.03). Our results indicate that DCE-MRI using both AIF methods is excellent in discriminating PCa from NNPT. If quantitative DCE-MRI is to be used as a biomarker in PCa, the same AIF method should be used consistently throughout the study. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:886 / 894
页数:9
相关论文
共 47 条
[1]   The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours [J].
Ahearn, TS ;
Staff, RT ;
Redpath, TW ;
Semple, SIK .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2041-2051
[2]   Scan-rescan variability in perfusion assessment of tumors in MRI using both model and data-derived arterial input functions [J].
Ashton, Edward ;
Raunig, David ;
Ng, Chaan ;
Kelcz, Fredrick ;
McShane, Teresa ;
Evelhoch, Jeffrey .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :791-796
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
Bland JM, 1995, STAT NOTES CALCULA 1, P310
[5]  
BRAWER MK, 1994, CANCER, V73, P678, DOI 10.1002/1097-0142(19940201)73:3<678::AID-CNCR2820730329>3.0.CO
[6]  
2-6
[7]  
Chen J, 2008, LECT NOTES COMPUT SC, V5241, P594, DOI 10.1007/978-3-540-85988-8_71
[8]   Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI [J].
Cheng, Hai-Ling Margaret .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :736-743
[9]   MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[10]   A comparison of two methods for estimating DCE-MRI parameters via individual and cohort based AIFs in prostate cancer: A step towards practical implementation [J].
Fedorov, Andriy ;
Fluckiger, Jacob ;
Ayers, Gregory D. ;
Li, Xia ;
Gupta, Sandeep N. ;
Tempany, Clare ;
Mulkern, Robert ;
Yankeelov, Thomas E. ;
Fennessy, Fiona M. .
MAGNETIC RESONANCE IMAGING, 2014, 32 (04) :321-329