Graphene-DNAzyme Based Biosensor for Amplified Fluorescence "Turn-On" Detection of Pb2+ with a High Selectivity

被引:348
作者
Zhao, Xu-Hua [1 ]
Kong, Rong-Mei [1 ]
Zhang, Xiao-Bing [1 ]
Meng, Hong-Min [1 ]
Liu, Wei-Na [1 ]
Tan, Weihong [1 ]
Shen, Guo-Li [1 ]
Yu, Ru-Qin [1 ]
机构
[1] Hunan Univ, State Key Lab Chemo Biosensing & Chemometr, Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
IN-VITRO SELECTION; LEAD; OXIDE; SENSOR; ION; SPECTROMETRY; CADMIUM; SAMPLES; COPPER;
D O I
10.1021/ac200843x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On the basis of the remarkable difference in affinity of graphene (GO) with ssDNA containing a different number of bases in length, we for the first time report a GO-DNAzyme based biosensor for amplified fluorescence "turn-on" detection of Pb2+. A FAM-labeled DNAzyme-substrate hybrid acted as both a molecular recognition module and signal reporter and GO as a superquencher. By taking advantage of the super fluorescence quenching efficiency of GO, our proposed biosensor exhibits a high sensitivity toward the target with a detection limit of 300 pM for Pb2+, which is lower than previously reported for catalytic beacons. Moreover, with the choice of a classic Pb2+-dependent GR-5 DNAzyme instead of 8-17 DNAzyme as the catalytic unit, the newly designed sensing system also shows an obviously improved selectivity than previously reported methods. Moreover, the sensing system was used for the determination of Pb2+ in river water samples with satisfying results.
引用
收藏
页码:5062 / 5066
页数:5
相关论文
共 39 条
[21]   Determination of trace copper, lead, cadmium, and iron in environmental and biological samples by flame atomic absorption spectrometry coupled to flow injection on-line coprecipitation preconcentration using DDTC-nickel as coprecipitate carrier [J].
Liu, JS ;
Chen, HW ;
Mao, XQ ;
Jin, X .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (04) :267-282
[22]   Improving fluorescent DNAzyme biosensors by combining inter- and intramolecular quenchers [J].
Liu, JW ;
Lu, Y .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6666-6672
[23]   PEGylated nanographene oxide for delivery of water-insoluble cancer drugs [J].
Liu, Zhuang ;
Robinson, Joshua T. ;
Sun, Xiaoming ;
Dai, Hongjie .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (33) :10876-+
[24]   A Graphene Platform for Sensing Biomolecules [J].
Lu, Chun-Hua ;
Yang, Huang-Hao ;
Zhu, Chun-Ling ;
Chen, Xi ;
Chen, Guo-Nan .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (26) :4785-4787
[25]   DETERMINATION OF CADMIUM, COPPER AND LEAD IN ENVIRONMENTAL-SAMPLES - AN EVALUATION OF FLOW-INJECTION ONLINE SORBENT EXTRACTION FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
MA, RL ;
VANMOL, W ;
ADAMS, F .
ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) :33-43
[26]   Graphene-Based Single-Bacterium Resolution Biodevice and DNA Transistor: Interfacing Graphene Derivatives with Nanoscale and Microscale Biocomponents [J].
Mohanty, Nihar ;
Berry, Vikas .
NANO LETTERS, 2008, 8 (12) :4469-4476
[27]   DNAzyme catalytic beacon sensors that resist temperature-dependent variations [J].
Nagraj, Nandini ;
Liu, Juewen ;
Sterling, Stephanie ;
Wu, Jenny ;
Lu, Yi .
CHEMICAL COMMUNICATIONS, 2009, (27) :4103-4105
[28]   Lead poisoning [J].
Needleman, H .
ANNUAL REVIEW OF MEDICINE, 2004, 55 :209-222
[29]  
Needleman H.L., 1992, HUMAN LEAD EXPOSURE
[30]   Comparison of inductively coupled plasma-atomic emission spectrometry, anodic stripping voltammetry and instrumental neutron-activation analysis for the determination of heavy metals in airborne particulate matter [J].
Ochsenkühn-Petropoulou, M ;
Ochsenkühn, KM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :629-632