Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures - Evaluation of the transcortical K-wire technique

被引:47
作者
Candal-Couto, JJ [1 ]
Williams, JR [1 ]
Sanderson, PL [1 ]
机构
[1] Freeman Rd Hosp, Dept Trauma & Orthopaed Surg, Newcastle Upon Tyne, Tyne & Wear, England
关键词
olecranon; tension-band-wiring; complication; forearm rotation;
D O I
10.1097/01.bot.0000164338.79013.10
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The tension-band-wiring technique is a well-accepted method of internal fixation of olecranon fractures. In addition, it is suggested that transcortical placement of the k-wires results in lower rates wire migration. We encountered two clinical cases in which transcortical placement of the k-wires led to impairment of forearm rotation. An anatomic study was conducted to study the effect of transcortical wire placement to avoid similar future complications. Using specimens from 10 embalmed cadavers, we found that transcortical wires inserted in < 30 degrees of ulnar angulation in the coronal plane to the medial ridge of the olecranon, impinged on the radial neck, supinator muscle, or biceps tendon. This was avoided in all 10 specimens when the wires were inserted, with the forearm in supination, at 30 degrees of ulnar angulation. We recommend this technique to be adopted to avoid forearm rotation impairment.
引用
收藏
页码:480 / 482
页数:3
相关论文
共 13 条
[1]   TENSION BAND WIRING - METHOD TO PREVENT BACKING OUT OF KIRSCHNER WIRE [J].
CHAPLIN, DM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1975, 7 (01) :57-57
[2]  
Finsen V, 2000, ORTHOPEDICS, V23, P1069
[3]  
Hak D J, 2000, J Am Acad Orthop Surg, V8, P266
[4]   ELBOW FUNCTION FOLLOWING TENSION BAND FIXATION OF DISPLACED FRACTURES OF THE OLECRANON [J].
HOLDSWORTH, BJ ;
MOSSAD, MM .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1984, 16 (03) :182-187
[5]   DRAWBACKS OF TRACTION-ABSORBING WIRING (TAW) IN DISPLACED FRACTURES OF THE OLECRANON [J].
JENSEN, CM ;
OLSEN, BB .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1986, 17 (03) :174-175
[6]   Fractures of the olecranon [J].
Karlsson, MK ;
Hasserius, R ;
Karlsson, C ;
Besjakov, J ;
Josefsson, PO .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (403) :205-212
[7]   Comparison of tension-band and figure-of-eight wiring techniques for treatment of olecranon fractures [J].
Karlsson, MK ;
Hasserius, R ;
Besjakov, J ;
Karlsson, C ;
Josefsson, PO .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (04) :377-382
[8]   COMPLICATIONS OF TENSION-BAND WIRING OF OLECRANON FRACTURES [J].
MACKO, D ;
SZABO, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (09) :1396-1401
[9]   Technological processes and modeling of opto-electromechanical microstructures [J].
Muller, R ;
Poladian, VM ;
Pavelescu, I ;
Manea, E ;
Cristea, D ;
Obreja, P .
MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2000, 3 (5-6) :427-431
[10]  
MURPHY DF, 1987, CLIN ORTHOP RELAT R, P215