Effect of a Bayesian Penalized Likelihood PET Reconstruction Compared With Ordered Subset Expectation Maximization on Clinical Image Quality Over a Wide Range of Patient Weights

被引:32
作者
Chilcott, Anna K. [1 ,2 ]
Bradley, Kevin M. [3 ]
McGowan, Daniel R. [1 ,4 ]
机构
[1] Oxford Univ Hosp NHS Fdn Trust, Churchill Hosp, Radiat Phys & Protect, Oxford OX3 7LE, England
[2] Royal Surrey Cty Hosp NHS Fdn Trust, Dept Nucl Med, Guildford, Surrey, England
[3] Oxford Univ Hosp NHS Fdn Trust, Churchill Hosp, Dept Radiol, Oxford, England
[4] Univ Oxford, Dept Oncol, Oxford, England
关键词
Bayesian penalized likelihood; FDG; ordered subset expectation maximization; PET/CT; signal-to-noise ratio; IMPACT;
D O I
10.2214/AJR.17.18060
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. A study was performed to compare background liver signal-to-noise ratio (SNR) and visually assessed image quality of clinical PET/CT studies from the same PET acquisition data reconstructed by Bayesian penalized likelihood (BPL) and ordered subset expectation maximization (OSEM) over a range of patient weights. MATERIALS AND METHODS. The effect of a BPL PET reconstruction algorithm on liver SNR and visually assessed image quality over a range of patient weights (41-196 kg; n = 108) was retrospectively compared with standard-of-care OSEM reconstruction on the same PET acquisition data after IV administration of F-18-FDG (4 MBq/kg). RESULTS. BPL showed no significant change (p > 0.05) in liver SNR with increasing weight and body mass index (BMI), whereas OSEM showed increasing noise with increasing weight and BMI. The liver SNR was significantly higher using BPL than a standard OSEM reconstruction (p < 0.0002 for all BMI groups). Visually assessed image quality declined at a greater rate with increasing weight and BMI in the OSEM images than with BPL images. CONCLUSION. BPL provides a more consistent visually assessed image quality and liver background SNR than does OSEM, with the greatest benefit for the heaviest patients.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 18 条
[1]   Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms [J].
Ahn, S ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (05) :613-626
[2]  
Ahn S. H., 2013, 2013 Abstracts IEEE International Conference on Plasma Science (ICOPS), DOI 10.1109/PLASMA.2013.6635185
[3]  
Asma E, 2012, IEEE NUCL SCI CONF R, P4062
[4]   FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0 [J].
Boellaard, Ronald ;
Delgado-Bolton, Roberto ;
Oyen, Wim J. G. ;
Giammarile, Francesco ;
Tatsch, Klaus ;
Eschner, Wolfgang ;
Verzijlbergen, Fred J. ;
Barrington, Sally F. ;
Pike, Lucy C. ;
Weber, Wolfgang A. ;
Stroobants, Sigrid ;
Delbeke, Dominique ;
Donohoe, Kevin J. ;
Holbrook, Scott ;
Graham, Michael M. ;
Testanera, Giorgio ;
Hoekstra, Otto S. ;
Zijlstra, Josee ;
Visser, Eric ;
Hoekstra, Corneline J. ;
Pruim, Jan ;
Willemsen, Antoon ;
Arends, Bertjan ;
Kotzerke, Joerg ;
Bockisch, Andreas ;
Beyer, Thomas ;
Chiti, Arturo ;
Krause, Bernd J. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (02) :328-354
[5]   Optimized dose regimen for whole-body FDG-PET imaging [J].
de Groot, Eleonore H. ;
Post, Nieky ;
Boellaard, Ronald ;
Wagenaar, Nils R. L. ;
Willemsen, Antoon T. M. ;
van Dalen, Jorn A. .
EJNMMI RESEARCH, 2013, 3 :1-11
[6]  
Halpern BS, 2005, J NUCL MED, V46, P603
[7]  
Halpern BS, 2004, J NUCL MED, V45, P797
[8]   3D implementation of Scatter Estimation in 3D PET [J].
Iatrou, M. ;
Manjeshwar, R. M. ;
Ross, S. G. ;
Thielemans, K. ;
Stearns, C. W. .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :2142-2145
[9]  
Jaskowiak CJ, 2005, J NUCL MED, V46, P424
[10]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174