Measurement of Rat Magnetocardiograms by Using a High-TC SQUID Magnetometer System

被引:3
作者
Kim, In-Seon [1 ]
Kwon, Hyuckchan [1 ]
Ahn, San [2 ]
Song, Jong-Hyun [2 ]
机构
[1] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
[2] Chungnam Natl Univ, Taejon 305764, South Korea
关键词
Biomagnetic measurement; high-T-C SQUID; magnetocardiography; rat; REPOLARIZATION;
D O I
10.1109/TASC.2010.2094994
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have measured biomagnetic signals in rat by using a high-T-C SQUID magnetometer system employing a small magnetically shielded box. For the rat cardiac magnetic field measurements, a healthy rat with body weight of about 350 g was anesthetized and fixed on a plastic xyz-stage in supine position inside the magnetically shielded box. We could obtain strong R-peak amplitude up to 56 pT with well defined P-, QRS-, T-wave, and ST-segment separating T-wave from QRS complex. We measured and analysed rat MCG waveforms for 5 x 5 grid measurements covering 60 mm x 60 mm area and 12 circular measurements centered at the heart position. This work demonstrates that the potential advantages of high-T-C SQUID magnetometer system in evaluating the rat MCG measurement for animal models of cardiac electrical activities.
引用
收藏
页码:497 / 500
页数:4
相关论文
共 37 条
  • [31] Development of Metallic Contaminant Detection System Using High-Tc RF SQUIDs for Li-ion Battery Slurry
    Tanaka, Saburo
    Hayashi, Masaru Sagawa Kanji
    Ohtani, Takeyoshi
    2019 IEEE INTERNATIONAL SUPERCONDUCTIVE ELECTRONICS CONFERENCE (ISEC), 2019,
  • [32] Estimation of Core Size Distribution of Magnetic Nanoparticles Using High- T c SQUID Magnetometer and Particle Swarm Optimizer-Based Inversion Technique
    Saari, Mohd Mawardi
    Sulaiman, Mohd Herwan
    Kiwa, Toshihiko
    IEICE TRANSACTIONS ON ELECTRONICS, 2024, E107C (06) : 176 - 182
  • [33] High critical temperature superconducting quantum interference device magnetometer with feedforward active noise control system for magnetocardiographic measurement in unshielded circumstances
    Mizukami, A
    Nishiura, H
    Sakuta, K
    Kobayashi, T
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2003, 392 : 1411 - 1415
  • [34] Pulsatile changes of blood echogenicity in rat arteries using a high-frequency ultrasound system
    Nam, Kweon-Ho
    Bok, Tae-Hoon
    Kong, Qi
    Paeng, Dong-Guk
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [35] In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): Feasibility and reproducibility
    Goebel, Jean-Christophe
    Bolbos, Radu
    Pinzano, Astrid
    Schaeffer, Mathilde
    Rengle, Adrian
    Galois, Laurent
    Etienne, Stephanie
    Netter, Patrick
    Loeuille, Damien
    Beuf, Olivier
    Gillet, Pierre
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2008, 18 (4-5) : 247 - 252
  • [36] Asymmetric radial expansion and contraction of rat carotid artery observed using a high-resolution ultrasound imaging system
    Nam, Kweon-Ho
    Bok, Tae-Hoon
    Jin, Changzhu
    Paeng, Dong-Guk
    ULTRASONICS, 2014, 54 (01) : 233 - 240
  • [37] Automated method for tracking vast numbers of FITC-Labeled RBCs in microvessels of rat brain in vivo using a high-speed confocal microscope system
    Tomita, Minoru
    Osada, Takashi
    Schiszler, Istvan
    Tomita, Yutaka
    Unekawa, Miyuki
    Toriumi, Haruki
    Tanahashi, Norio
    Suzuki, Norihiro
    MICROCIRCULATION, 2008, 15 (02) : 163 - 174