Leak detection in complex series pipelines by using the system frequency response method

被引:112
作者
Duan, Huan-Feng [1 ]
Lee, Pedro J. [2 ]
Ghidaoui, Mohamed S. [1 ]
Tung, Yeou-Koung [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Kowloon, Hong Kong, Peoples R China
[2] Univ Canterbury, Dept Civil & Nat Resources Engn, Christchurch 1, New Zealand
关键词
Complex series pipeline; frequency-response function; junction reflection; leak detection; transient; LOCATION;
D O I
10.1080/00221686.2011.553486
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research investigates the applicability of the transient-based frequency-response function (FRF) method for detecting leaks in complex series pipelines. The behaviour of transient waves in these pipelines with internal series junctions indicates that junction reflections modify the system resonant frequencies but have a small effect on the leak-induced information contained within the system frequency responses. The analogous method previously developed for single pipelines is extended to complex series pipe systems by using the analytical transfer matrix method herein and the extended method is validated by two simple numerical experimental cases consisting of 3-series pipes and 10-series pipes, respectively. The applied results indicate that the extended FRF method can be applied to detect single and multiple leaks in complex series pipelines as long as the location and size of the resonant peaks of system frequency responses are accurately determined.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 19 条
[1]   Transient test-based technique for leak detection in outfall pipes [J].
Brunone, B .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 1999, 125 (05) :302-306
[2]  
Brunone B., 2001, Journal of Hydraulic Research, V39, P1
[3]  
Chaudry M.H., 1987, Applied Hydraulic Transients, VSecond
[4]  
Cheong L.C., 1991, 18th Int. Water Supply Congress and Exhibition, V123, P709
[5]   A selective literature review of transient-based leak detection methods [J].
Colombo, Andrew F. ;
Lee, Pedro ;
Karney, Bryan W. .
JOURNAL OF HYDRO-ENVIRONMENT RESEARCH, 2009, 2 (04) :212-227
[6]   Standing wave difference method for leak detection in pipeline systems [J].
Covas, D ;
Ramos, H ;
de Almeida, AB .
JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2005, 131 (12) :1106-1116
[7]   Case Studies of Leak Detection and Location in Water Pipe Systems by Inverse Transient Analysis [J].
Covas, Didia ;
Ramos, Helena .
JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2010, 136 (02) :248-257
[8]   Essential system response information for transient-based leak detection methods [J].
Duan, Huan-Feng ;
Lee, Pedro J. ;
Ghidaoui, Mohamed S. ;
Tung, Yeou-Koung .
JOURNAL OF HYDRAULIC RESEARCH, 2010, 48 (05) :650-657
[9]   Pipe system diagnosis and leak detection by unsteady-state tests. 1. Harmonic analysis [J].
Ferrante, M ;
Brunone, B .
ADVANCES IN WATER RESOURCES, 2003, 26 (01) :95-105
[10]  
Ghidaoui M. S., 2005, Applied Mechanics Review, V58, P49, DOI 10.1115/1.1828050