Assessment of Volumetric Distortion Artifact in Filled Root Canals Using Different Cone-beam Computed Tomographic Devices

被引:39
作者
Celikten, Berkan [1 ,2 ,3 ]
Jacobs, Reinhilde [1 ,2 ]
Vasconcelos, Karla deFaria [1 ,2 ,4 ]
Huang, Yan [1 ,2 ,5 ]
Nicolielo, Laura Ferreira Pinheiro [1 ,2 ]
Orhan, Kaan [6 ]
机构
[1] Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Kapucijnenvoer 7,Blok A,Box 7001, B-3000 Leuven, Belgium
[2] Univ Hosp Leuven, Oral & Maxillofacial Surg, Kapucijnenvoer 7,Blok A,Box 7001, B-3000 Leuven, Belgium
[3] Ankara Univ, Dept Endodont, Fac Dent, Ankara, Turkey
[4] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Radiol, Dept Oral Diag, Piracicaba, Brazil
[5] Sichuan Univ, West China Coll Stomatol, State Key Lab Oral Dis, Chengdu, Sichuan, Peoples R China
[6] Ankara Univ, Dept DentoMaxillofacial Radiol, Fac Dent, Ankara, Turkey
基金
巴西圣保罗研究基金会;
关键词
Artifact; cone-beam computed tomographic machines; micro-computed tomographic imaging; root canal sealer; FILLING MATERIALS; TEETH; CT;
D O I
10.1016/j.joen.2017.03.035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Artifacts in cone-beam computed tomographic (CBCT) imaging may compromise radiodiagnosis. Obturation materials for endodontic treatment may present with variable material density and thus also cause distinct artifact expression. The aim of this study was to assess the volume distortion artifact of root canal sealers using CBCT devices and micro-CT imaging as a reference. Methods: Thirty single-root mandibular central incisors were used for this study. Teeth were prepared with EndoSequence rotary nickel-titanium files (Brasseler USA, Savannah, GA) and divided into 3 groups. Canals were obturated with gutta-percha and AH Plus root canal sealer (Dentsply Maillefer, Ballaigues, Switzerland) using single-cone filling techniques. Each tooth was scanned with different CBCT devices (ie, Promax 3D Max [Planmeca Inc, Roselle, IL], NewTom VGi evo [NewTom, Verona, Italy], and 3D Accuitomo 170 [J Morita, Kyoto, Japan]) with the same voxel size (0.2 mm3) and compared with micro CT imaging as a reference standard. Results: The results showed a significant difference in terms of volume distortion between micro-CT and CBCT images (P < .05). There were also significant differences among CBCT devices. Promax 3D Max measurements showed significantly larger root canal volumes than the other CBCT machines (P < .05). However, NewTom VGi evo and 3D Accuitomo 170 showed similar results without any significant difference (P > .05). Conclusions: CBCT devices showed more volumetric distortion artifact than micro-CT imaging. The volume was variable for different CBCT devices while scanning at the same voxel size. However, to assess the effect of sealer materials on CBCT imaging, further studies should be conducted for different sealers.
引用
收藏
页码:1517 / 1521
页数:5
相关论文
共 23 条
[1]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[2]   Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers [J].
Brito-Junior, M. ;
Santos, L. A. N. ;
Faria-e-Silva, A. L. ;
Pereira, R. D. ;
Sousa-Neto, M. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (01) :26-31
[3]   Evaluation of root canal sealer filling quality using a single-cone technique in oval shaped canals: An In vitro Micro-CT study [J].
Celikten, Berkan ;
Uzuntas, Ceren Feriha ;
Orhan, Ayse Isil ;
Orhan, Kaan ;
Tufenkci, Pelin ;
Kursun, Sebnem ;
Demiralp, Kemal Ozgur .
SCANNING, 2016, 38 (02) :133-140
[4]   Effect of root canal filling materials on dimensions of cone-beam computed tomography images [J].
Decurcio, Daniel Almeida ;
Bueno, Mike Reis ;
Goncalves de Alencar, Ana Helena ;
Lyra Porto, Olavo Cesar ;
Azevedo, Bruno Correa ;
Estrela, Carlos .
JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (02) :260-267
[5]  
Esmaeili Farzad, 2012, J Dent Res Dent Clin Dent Prospects, V6, P49
[6]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[7]   Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts [J].
Ferreira, L. M. ;
Visconti, M. A. P. G. ;
Nascimento, H. A. ;
Dallemolle, R. R. ;
Ambrosano, G. M. ;
Freitas, D. Q. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (05)
[8]   State-of-the-art on cone beam CT imaging for preoperative planning of implant placement [J].
Guerrero, ME ;
Jacobs, R ;
Loubele, M ;
Schutyser, F ;
Suetens, P ;
van Steenberghe, D .
CLINICAL ORAL INVESTIGATIONS, 2006, 10 (01) :1-7
[9]   Orofacial pain due to rare interosseous hemangioma first diagnosed as secondary to trauma [J].
Heir, Gary M. ;
Park, Richard Chan ;
Singer, Steven R. .
QUINTESSENCE INTERNATIONAL, 2016, 47 (08) :699-704
[10]   Evaluation and Reduction of Artifacts Generated by 4 Different Root-end Filling Materials by Using Multiple Cone-beam Computed Tomography Imaging Settings [J].
Helvacioglu-Yigit, Dilek ;
Kocasarac, Husniye Demirturk ;
Bechara, Boulos ;
Noujeim, Marcel .
JOURNAL OF ENDODONTICS, 2016, 42 (02) :307-314