Early thrombogenicity of coronary stents: comparison of bioresorbable polymer sirolimus-eluting and bare metal stents in an aortic rat model

被引:1
作者
Verhaegen, Carole [1 ]
Kautbally, Shakeel [1 ,2 ]
Zapareto, Diego Castanares [1 ,3 ]
Brusa, Davide [4 ]
Courtoy, Guillaume [5 ]
Aydin, Selda [6 ]
Bouzin, Caroline [5 ]
Oury, Cecile [7 ]
Bertrand, Luc [1 ]
Jacques, Pascal J. [8 ]
Beauloye, Christophe [1 ,2 ]
Horman, Sandrine [1 ]
Kefer, Joelle [1 ,2 ]
机构
[1] Univ Catholique Louvain UCLouvain, Pole Rech Cardiovasc, Inst Rech Expt & Clin IREC, Brussels, Belgium
[2] Univ Catholique Louvain UCLouvain, Div Cardiol, Clin Univ St Luc, Brussels, Belgium
[3] Univ Catholique Louvain UCLouvain, Div Intens Care, Clin Univ St Luc, Brussels, Belgium
[4] Univ Catholique Louvain UCLouvain, Plateforme Cytometrie Flux, Inst Rech Expt & Clin IREC, Brussels, Belgium
[5] Univ Catholique Louvain UCLouvain, IREC Imaging Platform 2IP, Brussels, Belgium
[6] Univ Catholique Louvain UCLouvain, Clin Univ St Luc, Div Anat Pathol, Brussels, Belgium
[7] Univ Liege, GIGA Cardiovasc Sci, Liege, Belgium
[8] Univ Catholique Louvain UCLouvain, Inst Mech Mat & Civil Engn, IMAP, Louvain La Neuve, Belgium
来源
AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE | 2020年 / 10卷 / 02期
关键词
Stent; thrombus; platelet; animal model; DUAL ANTIPLATELET THERAPY; BIODEGRADABLE POLYMER; RESTENOSIS; EVEROLIMUS; IMPLANTATION; THROMBOSIS; IMPACT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although 1-month dual antiplatelet therapy (DAPT) in patients treated with bare metal stents (BMS) is well established, the optimal duration of DAPT after implantation of a drug-eluting stent (DES) is still a matter of debate. The safety of shortened DAPT is under investigation due to concern about the risk of stent thrombosis. Data on platelet activation and prothrombotic response in vivo following bioresorbable polymer sirolimus-eluting stent (BP-SES) implantation are scarce. Objectives: The aim of our study was to compare the early thrombogenicity of BP-SES with that of BMS in an aortic rat model. Methods and Results: Overall, 30 rats underwent stent implantation in the abdominal aorta: BMS (Pro-Kinetic Energy; N=15) and BP-SES (Ultimaster Tansei; N=15) were compared in terms of their early thrombogenicity. CD62P exposure at the platelet surface and fibrinogen binding at the integrin receptor were not different between BMS and BP-SES over time. The thrombus coverage of the scaffold (0 vs. 0.1%, P=0.84) was similarly low in both groups at Day 28; thrombotic deposits had totally disappeared at Day 84. The endothelial strut coverage was similarly high at 1 month (90 vs. 95%, P=0.64) and 3 months (87 vs. 97%, P=0.99) following BMS and BP-SES implantation, respectively. Conclusions: This study demonstrates the low early thrombogenicity of a BP-SES implanted in an aortic rat model, which did not differ from a BMS. These data could be helpful to support the safety of a shortened 1-month DAPT duration following BP-SES implantation in the human coronary artery.
引用
收藏
页码:72 / 83
页数:12
相关论文
共 50 条
  • [31] A Comparison of the Conformability of Everolimus-Eluting Bioresorbable Vascular Scaffolds to Metal Platform Coronary Stents
    Gomez-Lara, Josep
    Garcia-Garcia, Hector M.
    Onuma, Yoshinobu
    Garg, Scot
    Regar, Evelyn
    De Bruyne, Bernard
    Windecker, Stefan
    McClean, Dougal
    Thuesen, Leif
    Dudek, Dariusz
    Koolen, Jacques
    Whitbourn, Robert
    Smits, Pieter C.
    Chevalier, Bernard
    Dorange, Cecile
    Veldhof, Susan
    Morel, Marie-Angele
    de Vries, Ton
    Ormiston, John A.
    Serruys, Patrick W.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (11) : 1190 - 1198
  • [32] Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
    Bangalore, Sripal
    Toklu, Bora
    Amoroso, Nicholas
    Fusaro, Mario
    Kumar, Sunil
    Hannan, Edward L.
    Faxon, David P.
    Feit, Frederick
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2013, 347
  • [33] Efficacy and safety of biodegradable polymer sirolimus-eluting stents versus durable polymer drug-eluting stents: A meta-analysis of randomized trials
    Yang, Yunjing
    Lei, Jiayan
    Huang, Wei
    Lei, Han
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 486 - 493
  • [34] Comparison Between Bare-Metal Stents, First-Generation Drug-Eluting Stents, and Bioresorbable Vascular Scaffolds
    Ng, Andrew Kei-Yan
    Ng, Pauline Yeung
    Siu, Chung-Wah
    Jim, Man-Hong
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06) : E467 - E473
  • [35] Long-Term Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents for Coronary Revascularization
    Raeber, Lorenz
    Jueni, Peter
    Nueesch, Eveline
    Kalesan, Bindu
    Wenaweser, Peter
    Moschovitis, Aris
    Khattab, Ahmed A.
    Bahlo, Maryam
    Togni, Mario
    Cook, Stephane
    Vogel, Rolf
    Seiler, Christian
    Meier, Bernhard
    Windecker, Stephan
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (21) : 2143 - 2151
  • [36] Randomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: Rationale and design of the BIOSCIENCE trial
    Pilgrim, Thomas
    Roffi, Marco
    Tueller, David
    Muller, Olivier
    Vuilliomenet, Andre
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Heg, Dik
    Jueni, Peter
    Windecker, Stephan
    [J]. AMERICAN HEART JOURNAL, 2014, 168 (03) : 256 - 261
  • [37] Long-term safety and efficacy of sirolimus-eluting stents versus bare-metal stents in real world clinical practice in Japan
    Kimura T.
    Morimoto T.
    Furukawa Y.
    Nakagawa Y.
    Kadota K.
    Iwabuchi M.
    Shizuta S.
    Shiomi H.
    Tada T.
    Tazaki J.
    Kato Y.
    Hayano M.
    Abe M.
    Tamura T.
    Shirotani M.
    Miki S.
    Matsuda M.
    Takahashi M.
    Ishii K.
    Tanaka M.
    Aoyama T.
    Doi O.
    Hattori R.
    Tatami R.
    Suwa S.
    Takizawa A.
    Takatsu Y.
    Takahashi M.
    Kato H.
    Takeda T.
    Lee J.-D.
    Nohara R.
    Ogawa H.
    Tei C.
    Horie M.
    Kambara H.
    Fujiwara H.
    Mitsudo K.
    Nobuyoshi M.
    Kita T.
    [J]. Cardiovascular Intervention and Therapeutics, 2011, 26 (3) : 234 - 245
  • [38] Angioscopic differences in neointimal coverage and in persistence of thrombus between sirolimus-eluting stents and bare metal stents after a 6-month implantation
    Takano, Masamichi
    Ohba, Takayoshi
    Inami, Shigenobu
    Seimiya, Koji
    Sakai, Shunta
    Mizuno, Kyoichi
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (18) : 2189 - 2195
  • [39] A randomized multicenter comparison of hybrid sirolimus-eluting stents with bioresorbable polymer versus everolimus-eluting stents with durable polymer in total coronary occlusion: rationale and design of the Primary Stenting of Occluded Native Coronary Arteries IV study
    Teeuwen, Koen
    Adriaenssens, Tom
    Van den Branden, Ben J. L.
    Henriques, Jose P. S.
    Van der Schaaf, Rene J.
    Koolen, Jacques J.
    Vermeersch, Paul H. M. J.
    Bosschaert, Mike A. R.
    Tijssen, Jan G. P.
    Suttorp, Maarten J.
    [J]. TRIALS, 2012, 13
  • [40] Randomized comparison of sirolimus eluting, and biolimus eluting bioresorbable polymer stents: the SORT-OUT VII optical coherence tomography study
    Andreasen, Lene N.
    Holm, Niels R.
    Balleby, Ida R.
    Krusell, Lars R.
    Maeng, Michael
    Jakobsen, Lars
    Veien, Karsten T.
    Hansen, Knud N.
    Kristensen, Steen D.
    Hjort, Jakob
    Kaltoft, Anne
    Dijkstra, Jouke
    Terkelsen, Christian J.
    Lassen, Jens F.
    Madsen, Morten
    Botker, Hans Erik
    Jensen, Lisette O.
    Christiansen, Evald H.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (03) : 329 - 338