Early thrombogenicity of coronary stents: comparison of bioresorbable polymer sirolimus-eluting and bare metal stents in an aortic rat model

被引:1
作者
Verhaegen, Carole [1 ]
Kautbally, Shakeel [1 ,2 ]
Zapareto, Diego Castanares [1 ,3 ]
Brusa, Davide [4 ]
Courtoy, Guillaume [5 ]
Aydin, Selda [6 ]
Bouzin, Caroline [5 ]
Oury, Cecile [7 ]
Bertrand, Luc [1 ]
Jacques, Pascal J. [8 ]
Beauloye, Christophe [1 ,2 ]
Horman, Sandrine [1 ]
Kefer, Joelle [1 ,2 ]
机构
[1] Univ Catholique Louvain UCLouvain, Pole Rech Cardiovasc, Inst Rech Expt & Clin IREC, Brussels, Belgium
[2] Univ Catholique Louvain UCLouvain, Div Cardiol, Clin Univ St Luc, Brussels, Belgium
[3] Univ Catholique Louvain UCLouvain, Div Intens Care, Clin Univ St Luc, Brussels, Belgium
[4] Univ Catholique Louvain UCLouvain, Plateforme Cytometrie Flux, Inst Rech Expt & Clin IREC, Brussels, Belgium
[5] Univ Catholique Louvain UCLouvain, IREC Imaging Platform 2IP, Brussels, Belgium
[6] Univ Catholique Louvain UCLouvain, Clin Univ St Luc, Div Anat Pathol, Brussels, Belgium
[7] Univ Liege, GIGA Cardiovasc Sci, Liege, Belgium
[8] Univ Catholique Louvain UCLouvain, Inst Mech Mat & Civil Engn, IMAP, Louvain La Neuve, Belgium
关键词
Stent; thrombus; platelet; animal model; DUAL ANTIPLATELET THERAPY; BIODEGRADABLE POLYMER; RESTENOSIS; EVEROLIMUS; IMPLANTATION; THROMBOSIS; IMPACT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although 1-month dual antiplatelet therapy (DAPT) in patients treated with bare metal stents (BMS) is well established, the optimal duration of DAPT after implantation of a drug-eluting stent (DES) is still a matter of debate. The safety of shortened DAPT is under investigation due to concern about the risk of stent thrombosis. Data on platelet activation and prothrombotic response in vivo following bioresorbable polymer sirolimus-eluting stent (BP-SES) implantation are scarce. Objectives: The aim of our study was to compare the early thrombogenicity of BP-SES with that of BMS in an aortic rat model. Methods and Results: Overall, 30 rats underwent stent implantation in the abdominal aorta: BMS (Pro-Kinetic Energy; N=15) and BP-SES (Ultimaster Tansei; N=15) were compared in terms of their early thrombogenicity. CD62P exposure at the platelet surface and fibrinogen binding at the integrin receptor were not different between BMS and BP-SES over time. The thrombus coverage of the scaffold (0 vs. 0.1%, P=0.84) was similarly low in both groups at Day 28; thrombotic deposits had totally disappeared at Day 84. The endothelial strut coverage was similarly high at 1 month (90 vs. 95%, P=0.64) and 3 months (87 vs. 97%, P=0.99) following BMS and BP-SES implantation, respectively. Conclusions: This study demonstrates the low early thrombogenicity of a BP-SES implanted in an aortic rat model, which did not differ from a BMS. These data could be helpful to support the safety of a shortened 1-month DAPT duration following BP-SES implantation in the human coronary artery.
引用
收藏
页码:72 / 83
页数:12
相关论文
共 50 条
[21]   Comparison of efficacy and safety between ultrathin bioresorbable polymer sirolimus-eluting stents and thin durable polymer drug-eluting stents: a systematic review and meta-analysis of the literature [J].
Zhai, Zhen-yu ;
Li, Ju-xiang .
CORONARY ARTERY DISEASE, 2019, 30 (08) :590-599
[22]   In vitro thrombogenicity of drug-eluting and bare metal stents [J].
Palmerini, Tullio ;
Barozzi, Chiara ;
Tomasi, Luciana ;
Della Riva, Diego ;
Marengo, Mario ;
Cicoria, Gianfranco ;
Bruno, Antonio G. ;
Bacchi-Reggiani, Maria-Letizia ;
Naldi, Marina ;
Bartolini, Manuela ;
Fanti, Stefano ;
Galie, Nazzareno ;
Stone, Gregg W. .
THROMBOSIS RESEARCH, 2020, 185 :43-48
[23]   Acute and long-term outcomes of ostial stentings among bare-metal stents, sirolimus-eluting stents, and paclitaxel-eluting stents [J].
Hsieh, I-Chang ;
Hsieh, Ming-Jer ;
Chang, Shang-Hung ;
Wang, Chao-Yung ;
Lee, Cheng-Hung ;
Lin, Fen-Chiung ;
Chen, Chun-Chi .
CORONARY ARTERY DISEASE, 2013, 24 (03) :224-230
[24]   Comparison of Everolimus-Eluting and Sirolimus-Eluting Coronary Stents 1-Year Outcomes from the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET) [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Natsuaki, Masahiro ;
Shiomi, Hiroki ;
Igarashi, Keiichi ;
Kadota, Kazushige ;
Tanabe, Kengo ;
Morino, Yoshihiro ;
Akasaka, Takashi ;
Takatsu, Yoshiki ;
Nishikawa, Hideo ;
Yamamoto, Yoshito ;
Nakagawa, Yoshihisa ;
Hayashi, Yasuhiko ;
Iwabuchi, Masashi ;
Umeda, Hisashi ;
Kawai, Kazuya ;
Okada, Hisayuki ;
Kimura, Kazuo ;
Simonton, Charles A. ;
Kozuma, Ken .
CIRCULATION, 2012, 126 (10) :1225-+
[25]   Ten-year survival of patients undergoing coronary angioplasty with first-generation sirolimus-eluting stents and bare-metal stents [J].
Vale, Nelson ;
Madeira, Sergio ;
Almeida, Manuel ;
Raposo, Luis ;
Freitas, Pedro ;
Castro, Mariana ;
Rodrigues, Gustavo ;
Oliveira, Afonso ;
Brito, Joao ;
Leal, Silvio ;
Goncalves, Pedro de Araujo ;
Gabriel, Henrique Mesquita ;
Teles, Rui Campante ;
Gomes, Ricardo Seabra .
REVISTA PORTUGUESA DE CARDIOLOGIA, 2020, 39 (11) :639-647
[26]   Initial and long-term outcomes of sirolimus-eluting stents for calcified lesions compared with bare-metal stents [J].
Seo, Atsushi ;
Fujii, Takuro ;
Inoue, Terumasa ;
Onoda, Satom ;
Koga, Atsushi ;
Tanaka, Yasuyuki ;
Chin, Keiichi ;
Kurusu, Takashi ;
Takikawa, Kazutoshi ;
Shibata, Takahiro ;
Taniguchi, Masayuki ;
Mochizuki, Seibu .
INTERNATIONAL HEART JOURNAL, 2007, 48 (02) :137-147
[27]   Comparison of Zotarolimus-Eluting Stents With Sirolimus- and Paclitaxel-Eluting Stents for Coronary Revascularization The ZEST (Comparison of the Efficacy and Safety of Zotarolimus-Eluting Stent with Sirolimus-Eluting and PacliTaxel-Eluting Stent for Coronary Lesions) Randomized Trial [J].
Park, Duk-Woo ;
Kim, Young-Hak ;
Yun, Sung-Cheol ;
Kang, Soo-Jin ;
Lee, Seung-Whan ;
Lee, Cheol-Whan ;
Park, Seong-Wook ;
Seong, In-Whan ;
Lee, Jae-Hwan ;
Tahk, Seung-Jea ;
Jeong, Myung-Ho ;
Jang, Yangsoo ;
Cheong, Sang-Sig ;
Yang, Joo-Young ;
Lim, Do-Sun ;
Seung, Ki-Bae ;
Chae, Jei-Keon ;
Hur, Seung-Ho ;
Lee, Sang-Gon ;
Yoon, Junghan ;
Lee, Nae-Hee ;
Choi, Young-Jin ;
Kim, Hyun-Sook ;
Kim, Kee-Sik ;
Kim, Hyo-Soo ;
Hong, Taeg-Jong ;
Park, Hun-Sik ;
Park, Seung-Jung .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (15) :1187-1195
[28]   Predictors and outcomes of acute recoil after ultrathin bioresorbable polymer sirolimus-eluting stents implantation: an intravascular ultrasound in native coronary arteries [J].
Sato, Takao ;
Goto, Sonoka ;
Yuasa, Sho ;
Akazawa, Kohei ;
Aizawa, Yoshifusa .
CORONARY ARTERY DISEASE, 2022, 31 (01) :18-24
[29]   5-Year Clinical Outcomes After Sirolimus-Eluting Stent Implantation Insights From a Patient-Level Pooled Analysis of 4 Randomized Trials Comparing Sirolimus-Eluting Stents With Bare-Metal Stents [J].
Caixeta, Adriano ;
Leon, Martin B. ;
Lansky, Alexandra J. ;
Nikolsky, Eugenia ;
Aoki, Jiro ;
Moses, Jeffrey W. ;
Schofer, Joachim ;
Morice, Marie-Claude ;
Schampaert, Erick ;
Kirtane, Ajay J. ;
Popma, Jeffrey J. ;
Parise, Helen ;
Fahy, Martin ;
Mehran, Roxana .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (10) :894-902
[30]   A Randomized Trial Comparing the NeoVas Sirolimus-Eluting Bioresorbable Scaffold and Metallic Everolimus-Eluting Stents [J].
Han, Yaling ;
Xu, Bo ;
Fu, Guosheng ;
Wang, Xiaozeng ;
Xu, Kai ;
Jin, Chongying ;
Tao, Ling ;
Li, Lang ;
Hou, Yuqing ;
Su, Xi ;
Fang, Quan ;
Chen, Lianglong ;
Liu, Huiliang ;
Wang, Bin ;
Yuan, Zuyi ;
Gao, Chuanyu ;
Zhou, Shenghua ;
Sun, Zhongwei ;
Zhao, Yanyan ;
Guan, Changdong ;
Stone, Gregg W. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (03) :261-272