Optimized transition-edge x-ray microcalorimeter with 2.4 eV energy resolution at 5.9 keV

被引:67
作者
Ullom, JN [1 ]
Beall, JA [1 ]
Doriese, WB [1 ]
Duncan, WD [1 ]
Ferreira, L [1 ]
Hilton, GC [1 ]
Irwin, KD [1 ]
Reintsema, CD [1 ]
Vale, LR [1 ]
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
基金
美国国家航空航天局;
关键词
D O I
10.1063/1.2061865
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present measurements from a series of transition-edge x-ray microcalorimeters designed for optimal energy resolution. We used the geometry of the sensors to control their heat capacity and employed additional normal metal features and a perpendicular magnetic field to control the sharpness of the superconducting-to-normal transition. These degrees of control allow an optimal selection of sensor saturation energy and noise. Successive design changes improved the measured energy resolution of the sensors from 4.5 eV full width at half maximum at 5.9 keV to 2.4 eV at 5.9 keV. Sensors with this energy resolution are well matched to applications in x-ray astrophysics and terrestrial materials analysis.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 13 条
[1]   PERFORMANCE CHARACTERISTICS OF A NEW LOW-TEMPERATURE BOLOMETER [J].
BOYLE, WS ;
RODGERS, KF .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1959, 49 (01) :66-69
[2]   High-resolution gamma-ray spectrometers using bulk absorbers coupled to Mo/Cu multilayer superconducting transition-edge sensors [J].
Chow, DT ;
Loshak, A ;
van den Berg, ML ;
Frank, M ;
Barbee, TW ;
Labov, SE .
HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 :67-75
[3]   K alpha(1,2) and K beta(1,3) x-ray emission lines of the 3d transitions metals [J].
Holzer, G ;
Fritsch, M ;
Deutsch, M ;
Hartwig, J ;
Forster, E .
PHYSICAL REVIEW A, 1997, 56 (06) :4554-4568
[4]   A Mo-Cu superconducting transition-edge microcalorimeter with 4.5 eV energy resolution at 6 keV [J].
Irwin, KD ;
Hilton, GC ;
Martinis, JM ;
Deiker, S ;
Bergren, N ;
Nam, SW ;
Rudman, DA ;
Wollman, DA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :184-187
[5]   X-ray detection using a superconducting transition-edge sensor microcalorimeter with electrothermal feedback [J].
Irwin, KD ;
Hilton, GC ;
Wollman, DA ;
Martinis, JM .
APPLIED PHYSICS LETTERS, 1996, 69 (13) :1945-1947
[6]   AN APPLICATION OF ELECTROTHERMAL FEEDBACK FOR HIGH-RESOLUTION CRYOGENIC PARTICLE-DETECTION [J].
IRWIN, KD .
APPLIED PHYSICS LETTERS, 1995, 66 (15) :1998-2000
[7]   THERMAL DETECTORS AS X-RAY SPECTROMETERS [J].
MOSELEY, SH ;
MATHER, JC ;
MCCAMMON, D .
JOURNAL OF APPLIED PHYSICS, 1984, 56 (05) :1257-1262
[8]  
Porter F.S., COMMUNICATION
[9]   Low-temperature detectors in X-ray astronomy [J].
Porter, FS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3) :354-358
[10]   Progress in the development of Mo/Au transition-edge sensors for x-ray spectroscopy [J].
Stahle, CK ;
Brekosky, RP ;
Figueroa-Feliciano, E ;
Finkbeiner, FM ;
Gygax, JD ;
Li, MJ ;
Lindeman, MA ;
Porter, FS ;
Tralshawala, N .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 :367-375