Spherical aberration for expanding depth of focus

被引:0
作者
Fernandez, Joaquin [1 ]
Rodriguez-Vallejo, Manuel [1 ]
Burguera, Noemi [1 ]
Rocha-de-Lossada, Carlos [1 ,2 ]
Pinero, David P. [3 ,4 ]
机构
[1] VITHAS Hosp, Dept Ophthalmol Qvis, Carr El Mami Viator,Km 1, Almeria 04120, Spain
[2] Hosp Virgen Nieves, Dept Ophthalmol, Av Fuerzas Armadas, Granada, Spain
[3] Univ Alicante, Dept Opt Pharmacol & Anat, Alicante, Spain
[4] Vithas Medimar Int Hosp, Dept Ophthalmol IMQO Oftalmar, Alicante, Spain
关键词
MONOVISION ABLATION PROFILE; HIGHER-ORDER ABERRATIONS; PATIENT-REPORTED OUTCOMES; MICRO-MONOVISION; ADAPTIVE OPTICS; EXTENDED DEPTH; VISUAL-ACUITY; EXCIMER-LASER; OF-FOCUS; SURGICAL-TREATMENT;
D O I
10.1097/j.jcrs.0000000000000713
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The increase in the depth of focus (DoF) for the treatment of presbyopia or cataracts is a topic of great interest for anterior segment surgeons who have seen how new surgical possibilities to achieve DoF enlargement have emerged. Nowadays, several technologies to extend the DoF are available, from corneal laser refractive surgery procedures in presbyopia to intraocular lens (IOL) implantation in cataract or refractive lens exchange. Some of these procedures are based on aspheric profiles, either in the cornea or in the IOL, which modulate the spherical aberration (SA) and, therefore, extend the light energy on different focal planes. The aim of this narrative review was to give an overall picture about the reasons why there is not a general solution persistent along time of SA induction to extend DoF, especially considering that SA depends on pupil diameter and this decreases with age. Copyright (C) 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:1587 / 1595
页数:9
相关论文
共 68 条
[1]   Extended depth of focus intraocular lenses for presbyopia [J].
Akella, Sruti S. ;
Juthani, Viral V. .
CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) :319-323
[2]  
Ang RET, 2016, EYE VISION, V3, P1
[3]   A Comparative Evaluation of Visual, Refractive, and Patient-Reported Outcomes of Three Extended Depth of Focus (EDOF) Intraocular Lenses [J].
Ang, Robert Edward ;
Picache, Gian Carlo S. ;
Rivera, Mark Christian R. ;
Lopez, Lord Ryan L. ;
Cruz, Emerson M. .
CLINICAL OPHTHALMOLOGY, 2020, 14 :2339-2351
[4]   Clinical and aberrometric evaluation of a new extended depth-of-focus intraocular lens based on spherical aberration [J].
Bellucci, Roberto ;
Cargnoni, Miriam ;
Bellucci, Carlo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (07) :919-926
[5]   A New Extended Depth of Focus Intraocular Lens Based on Spherical Aberration [J].
Bellucci, Roberto ;
Curatolo, Maria C. .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (06) :389-+
[6]   Optimizing the subjective depth-of-focus with combinations of fourth- and sixth-order spherical aberration [J].
Benard, Yohann ;
Lopez-Gil, Norberto ;
Legras, Richard .
VISION RESEARCH, 2011, 51 (23-24) :2471-2477
[7]   Subjective depth of field in presence of 4th-order and 6th-order Zernike spherical aberration using adaptive optics technology [J].
Benard, Yohann ;
Lopez-Gil, Norberto ;
Legras, Richard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12) :2129-2138
[8]  
Breyer DRH, 2017, ASIA-PAC J OPHTHALMO, V6, P339, DOI 10.22608/APO.2017186
[9]   Redefining vision assessment [J].
Brown, Colin E. ;
Waring, George O. ;
Rocha, Karolinne M. .
CURRENT OPINION IN OPHTHALMOLOGY, 2020, 31 (04) :225-233
[10]  
Camps VJ, 2017, J OPHTHALMOL, V2017, P1