Environmental monitoring of semi volatile polyciclic aromatic hydrocarbons by means of diffusive sampling devices and GC-MS analysis

被引:12
作者
Bertoni, G [1 ]
Tappa, R [1 ]
Cecinato, A [1 ]
机构
[1] CNR, Ist Inquinamento Atmosfer, I-00016 Monterotondo Scalo RM, Italy
关键词
gas chromatography; GC-MS; diffusive sampling; polycyclic aromatics; urban air sampling;
D O I
10.1007/BF02490348
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A molecular diffusion-based sampling device (known as Analyst 2) is presented for the determination of semi-volatile polyaromatic hydrocarbons (PAH's) in air. It has been developed from a previous model (i.e. Analyst), which was suitable for volatile hydrocarbons. The new model is capable of collect enough gaseous PAH's to allow GC-MS analysis of enriched samples after two-month exposition to either urban or suburban air. The adsorbing material adopted for enriching the PAH's, i.e. Carbopack C, allows good recoveries of analytes ranging from naphthalene to chrysene, when only a single solvent extraction is run at ambient temperature. Some field experiments generated gaseous PAH concentrations that were in agreement with those expected at urban and suburban sites.
引用
收藏
页码:S312 / S316
页数:5
相关论文
共 13 条
  • [1] TECHNIQUES FOR REDUCING PEN PLOTTING TIME
    ANDERSON, DP
    [J]. ACM TRANSACTIONS ON GRAPHICS, 1983, 2 (03): : 197 - 212
  • [2] Bertoni G, 2000, ANN CHIM-ROME, V90, P249
  • [3] EVALUATION TESTS AND APPLICATIONS OF A DOUBLE-LAYER TUBE-TYPE PASSIVE SAMPLER
    BERTONI, G
    CANEPARI, S
    ROTATORI, M
    FRATARCANGELI, R
    LIBERTI, A
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 522 : 285 - 294
  • [4] COMPARISON OF PHYSICAL AND GAS-CHROMATOGRAPHIC PROPERTIES OF STERLING FT AND CARBOPACK-C GRAPHITIZED CARBON-BLACKS
    BRUNER, F
    BERTONI, G
    CICCIOLI, P
    [J]. JOURNAL OF CHROMATOGRAPHY, 1976, 120 (02): : 307 - 319
  • [5] EXPERIMENTS ON DISTRIBUTION OF ORGANIC POLLUTANTS BETWEEN AIRBORNE PARTICULATE MATTER AND CORRESPONDING GAS-PHASE
    CAUTREELS, W
    VANCAUWENBERGHE, K
    [J]. ATMOSPHERIC ENVIRONMENT, 1978, 12 (05) : 1133 - 1141
  • [6] *INT AG RES CANC, 1983, MON EV CARC RISK H 1, V32
  • [7] *INT AG RES CANC, 1987, IARC MON EV CARC R S, V7
  • [8] KONIG J, 1978, ATMOS ENVIRON, V12, P1133
  • [9] MODIFICATION AND EVALUATION OF A HIGH-VOLUME AIR SAMPLER FOR PESTICIDES AND SEMIVOLATILE INDUSTRIAL ORGANIC-CHEMICALS
    LEWIS, RG
    JACKSON, MD
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (03) : 592 - 594
  • [10] MEASUREMENTS OF THE GAS PARTICLE DISTRIBUTIONS OF ATMOSPHERIC ORGANIC-COMPOUNDS
    LIGOCKI, MP
    PANKOW, JF
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1989, 23 (01) : 75 - 83