Assessing graphite and stainless-steel for electrochemical sensing of biofilm growth in chlorinated drinking water systems

被引:35
作者
Bimakr, Fahimeh [1 ,2 ]
Ginige, Maneesha P. [1 ]
Kaksonen, Anna H. [1 ,2 ]
Sutton, David C. [2 ]
Puzon, Geoffrey J. [1 ]
Cheng, Ka Yu [1 ,3 ]
机构
[1] CSIRO Land & Water, 147 Underwood Ave, Floreat, WA 6014, Australia
[2] Univ Western Australia, Sch Biomed Sci, 35 Stirling Highway, Crawley, WA 6009, Australia
[3] Murdoch Univ, Sch Engn & Informat Technol, Murdoch, WA 6150, Australia
关键词
Drinking water distribution systems (DWDSs); Disinfection; Electrochemical impedance spectroscopy (EIS); Open circuit potential (OCP); NAEGLERIA-FOWLERI; RAPID DETECTION; IMPEDANCE; BACTERIAL; NANOPARTICLES; CORROSION; CARBON; ELECTRODE; SURFACES; SENSOR;
D O I
10.1016/j.snb.2018.09.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Infectious diseases caused by pathogens (e.g. bacteria, viruses, protozoa) are the most common and widespread health risk associated with drinking water. Biofilms are known to harbour pathogens in drinking water distribution systems (DWDSs). Disinfectant dosing (e.g. chlorination) is an effective method to control biofilm growth, but overdosing can lead to formation of harmful disinfection by-products. One approach to prevent overdosing is the development of a dynamic biofilm-sensing system that can guide disinfectant dosing on a real-time basis. This study explored the use of electrochemical impedance spectroscopy (EIS) and open circuit potential (OCP) measurements for the development of a biofilm sensor. Two materials (graphite and stainless steel) were compared for their sensitivity as an electrode material for biofilm detection, using incubation experiments in which freshwater from a drinking water supply dam was the source of microbes for biofilm formation. EIS and OCP measurements were correlated with biofilm growth-related parameters (flow cytometer cell counts). Chlorination (4.4 mg Cl-2/L) was included as a treatment for biofilm destruction. Among a range of electrochemical parameters determined, double-layer capacitance derived from the equivalent circuit model of EIS showed the strongest positive linear relationship with cell density for each electrode type (R-2 > 0.9). Stainless steel was 10-fold more sensitive than graphite (2 x 10(-5) vs. 2 x 10(-6) % capacitance change/cell cm(-2) ratio), suggesting that stainless steel is a more effective material for biofilm sensing. The observable changes in capacitance were exclusively triggered by biofilm formation, and chlorine residuals did not affect the capacitance of either electrode type. The results indicate the potential of using stainless steel for development of a practical biofilm sensor for water utilities.
引用
收藏
页码:526 / 534
页数:9
相关论文
共 49 条
[1]   Effect of biofilms grown at various chloramine residuals on chloramine decay [J].
Adhikari, Rekha A. ;
Sathasivan, A. ;
Krishna, K. C. Bal .
WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2012, 12 (04) :463-469
[2]  
AlAbbas FM, 2013, INT J ELECTROCHEM SC, V8, P859
[3]  
[Anonymous], 2004, World Health Organization Guidelines for Drinking Water Quality Third Edition, V1
[4]   Electrical detection and characterization of bacterial adhesion using electrochemical impedance spectroscopy-based flow chamber [J].
Bayoudh, Sonia ;
Othmane, Ali ;
Ponsonnet, Laurence ;
Ben Ouada, Hafedh .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 318 (1-3) :291-300
[5]  
Bruijs M.C.M., 2001, J POWER PLANT CHEM, V3, P400
[6]   Progress in the electrochemical modification of graphene-based materials and their applications [J].
Chakrabarti, M. H. ;
Low, C. T. J. ;
Brandon, N. P. ;
Yufit, V. ;
Hashim, M. A. ;
Irfan, M. F. ;
Akhtar, J. ;
Ruiz-Trejo, E. ;
Hussain, M. A. .
ELECTROCHIMICA ACTA, 2013, 107 :425-440
[7]   Microbially influenced corrosion of stainless steel by marine bacterium Vibrio natriegens: (I) Corrosion behavior [J].
Cheng, Sha ;
Tian, Jintao ;
Chen, Shougang ;
Lei, Yanhua ;
Chang, Xueting ;
Liu, Tao ;
Yin, Yansheng .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (03) :751-755
[8]  
Dadafarin H, 2013, INT J ELECTROCHEM SC, V8, P369
[9]   In situ monitoring of the nascent Pseudomonas fluorescens Biofilm response to variations in the dissolved organic carbon level in low-nutrient water by attenuated total reflectance-fourier transform infrared spectroscopy [J].
Delille, Anne ;
Quiles, Fabienne ;
Humbert, Francois .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (18) :5782-5788
[10]   Electrochemical activity of Geobacter sulfurreducens biofilms on stainless steel anodes [J].
Dumas, Claire ;
Basseguy, Regine ;
Bergel, Alain .
ELECTROCHIMICA ACTA, 2008, 53 (16) :5235-5241