Experimental investigation on seismic behavior of corroded RC columns under artificial climate environment and electrochemical chloride extraction: A comparative study

被引:67
作者
Dai, Kuang-Yu [1 ]
Liu, Chang [1 ]
Lu, Da-Gang [1 ]
Yu, Xiao-Hui [1 ,2 ]
机构
[1] Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Minist Educ, Harbin 150090, Peoples R China
[2] Guangxi Univ, Guangxi Key Lab Disaster Prevent & Engn Safety, Nanning 530000, Peoples R China
基金
中国国家自然科学基金;
关键词
Corrosion; Seismic performance; RC column; Artificial climate environment; Electrochemical chloride extraction; X-ray diffraction; REINFORCED-CONCRETE COLUMNS; RESIDUAL CAPACITY; INDUCED CORROSION; REBAR CORROSION; STEEL; DEGRADATION; PERFORMANCE; STRENGTH; BARS; TESTS;
D O I
10.1016/j.conbuildmat.2020.118014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion of reinforcement bars can cause reinforced concrete (RC) columns more vulnerable under seismic loads. In this study, the seismic behavior of corroded RC columns was experimentally studied with a focus on the comparison between two different accelerated corrosion techniques by using artificial climate environment (ACE) and electrochemical chloride extraction (ECE). To do this, six RC square columns were designed and fabricated as the test specimens. The test specimens were categorized into two groups with a low level and a high level of axial compression ratio (i.e., 0.1 and 0.45), respectively, and each group includes three test specimens, i.e., an uncorroded column and two corroded columns under ACE and ECE techniques. An X-ray diffraction approach was used to examine the major ingredients of corrosion products attached on the corroded reinforcement bars under ACE and ECE techniques. The column specimens were subjected to repeated cyclic loadings, and the failure modes, hysteresis and backbone curves, stiffness degradation, ductility level and energy dissipation of the specimens corroded under different techniques were compared. The results show that, under a consistent target corrosion level, the ECE corrosion technique can cause more significant damage to the corroded RC columns than the ACE corrosion technique, leading to a change of failure mode and worse hysteretic performance. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:20
相关论文
共 72 条
[1]   Corrosion rate evolution in concrete structures exposed to the atmosphere [J].
Andrade, C ;
Alonso, C ;
Sarría, J .
CEMENT & CONCRETE COMPOSITES, 2002, 24 (01) :55-64
[2]  
[Anonymous], MAG CONCR RES
[3]  
[Anonymous], JIANZHU JIEGOU XUEBA
[4]  
[Anonymous], CEM CONCR COMPOS
[5]  
[Anonymous], 2015, JGJ/T 101-2018
[6]  
[Anonymous], J XIAN U ARCHIT TECH
[7]  
[Anonymous], ACI STRUCT J
[8]  
[Anonymous], ACI MAT J
[9]  
[Anonymous], P 8 INT C FRACT MECH
[10]  
[Anonymous], MAG CONCR RES