Existence of a typical threshold in the response of human mesenchymal stem cells to a peak and valley topography

被引:39
作者
Bigerelle, M. [2 ]
Giljean, S. [3 ]
Anselme, K. [1 ]
机构
[1] Univ Haute Alsace, CNRS LRC7228, Inst Sci Mat Mulhouse IS2M, F-68057 Mulhouse, France
[2] Univ Technol Compiegne, UMR CNRS 6253, Lab Roberval, Ctr Rech Royallieu, F-60205 Compiegne, France
[3] Univ Haute Alsace, Equipe MMPF, LPMT, EAC CNRS 7189,IUT Dept GMP, F-68093 Mulhouse, France
关键词
Roughness; Titanium; Cell adhesion; hMSCs; Modelling; SURFACE-ROUGHNESS; OSTEOBLAST RESPONSE; CONTACT GUIDANCE; TITANIUM; ADHESION; MORPHOLOGY; DIFFERENTIATION; NANOTOPOGRAPHY; PROLIFERATION; CHEMISTRY;
D O I
10.1016/j.actbio.2011.05.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our objective in this study was to determine whether a threshold in sensitivity of human mesenchymal stem cells (hMSC) to isotropic roughness exists. Using electrical discharge machining a very wide range of roughnesses (1.2 mu m < R-a < 21 mu gm) with a perfectly isotropic, fractal and self-affine topography can be produced on titanium, with a range of roughness overlapping the hMSC length dimensions. The curve of the number of adherent hMSC after 2 days culture as a function of roughness showed a U-shape with a minimum number of attached cells for a roughness amplitude R-a = 4.5 mu m and a distance between surface features (width of peaks and valleys) S-m = 110 mu m. The maximum cell number was observed at the lowest and highest roughnesses. Due to this very wide range of roughness it was possible to demonstrate that the response of hMSC to roughness varies with the dimensions of the surface features relative to the cell size. Above or below their own size hMSC essentially adhere to the nano and submicron features. When the surface displays features about the same size as hMSC the curvature of these surface features will decrease the number of attached cells by a factor of two. A modelling approach is proposed to help the interpretation of these results. It is hypothesized that this minimal adhesion is a consequence of an unfavourable stress imposed on the cell cytoskeleton. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:3302 / 3311
页数:10
相关论文
共 47 条
[1]   Statistical demonstration of the relative effect of surface chemistry and roughness on human osteoblast short-term adhesion [J].
Anselme, K ;
Bigerelle, M .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2006, 17 (05) :471-479
[2]   Topography effects of pure titanium substrates on human osteoblast long-term adhesion [J].
Anselme, K ;
Bigerelle, M .
ACTA BIOMATERIALIA, 2005, 1 (02) :211-222
[3]   Modelling approach in cell/material interactions studies [J].
Anselme, K ;
Bigerelle, M .
BIOMATERIALS, 2006, 27 (08) :1187-1199
[4]   In vitro control of human bone marrow stromal cells for bone tissue engineering [J].
Anselme, K ;
Broux, O ;
Noel, B ;
Bouxin, B ;
Bascoulergue, G ;
Dudermel, AF ;
Bianchi, F ;
Jeanfils, J ;
Hardouin, P .
TISSUE ENGINEERING, 2002, 8 (06) :941-953
[5]  
ANSELME K, INT MAT REV IN PRESS
[6]   Induction of cell polarization and migration by a gradient of nanoscale variations in adhesive ligand spacing [J].
Arnold, Marco ;
Hirschfeld-Warneken, Vera C. ;
Lohmueller, Theobald ;
Heil, Patrick ;
Bluemmel, Jacques ;
Cavalcanti-Adam, Elisabetta A. ;
Lopez-Garcia, Monica ;
Walther, Paul ;
Kessler, Horst ;
Geiger, Benjamin ;
Spatz, Joachim P. .
NANO LETTERS, 2008, 8 (07) :2063-2069
[7]   Substratum roughness alters the growth, area, and focal adhesions of epithelial cells, and their proximity to titanium surfaces [J].
Baharloo, B ;
Textor, M ;
Brunette, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 74A (01) :12-22
[8]   The effect of different surface morphology and roughness on osteoblast-like cells [J].
Ball, Michael ;
Grant, David M. ;
Lo, Wei-Jen ;
Scotchford, Colin A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 86A (03) :637-647
[9]   Bootstrap analysis of the relation between initial adhesive events and long-term cellular functions of human osteoblasts cultured on biocompatible metallic substrates [J].
Bigerelle, M ;
Anselme, K .
ACTA BIOMATERIALIA, 2005, 1 (05) :499-510
[10]  
BIGERELLE M, J ADHESION IN PRESS