Automated on-line dialysis for sample preparation for gas chromatography: Determination of benzodiazepines in human plasma

被引:18
作者
HerraezHernandez, R [1 ]
Louter, AJH [1 ]
vandeMerbel, NC [1 ]
Brinkman, UAT [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
关键词
automated on-line dialysis; benzodiazepines; gas chromatography; plasma;
D O I
10.1016/0731-7085(95)01703-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line dialysis-solid-phase extraction-gas chromatographic (GC) approach has been developed for the determination of drugs in plasma, using some benzodiazepines as model compounds. Clean-up is based on performing the dialysis of 100 mu l samples for 7 min using water as acceptor phase and trapping the diffused analytes on a PLRP-S copolymer precolumn. After drying of the precolumn with nitrogen for 15 min, the analytes are desorbed with ethyl acetate (275 mu l) and injected on-line into the GC system via a loop-type interface. The system provides a very efficient clean-up, and offers the possibility of adding chemical agents which can help to reduce drug-protein binding and, thus, increase sensitivity. To demonstrate the potential of the described approach, the determination of benzodiazepines in plasma at their therapeutical levels is used as an example with flame ionization, thermionic and mass-selective detection.
引用
收藏
页码:1077 / 1087
页数:11
相关论文
共 19 条
[1]   DETERMINATION OF LOW PARTS PER BILLION LEVELS OF AMINES IN URINE BY LIQUID MEMBRANE SAMPLE CLEANUP DIRECTLY COUPLED TO A GAS-LIQUID CHROMATOGRAPH [J].
AUDUNSSON, G .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1340-1347
[2]   CAPILLARY GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC METHOD FOR THE IDENTIFICATION AND QUANTIFICATION OF SOME BENZODIAZEPINES AND THEIR UNCONJUGATED METABOLITES IN PLASMA [J].
DROUETCOASSOLO, C ;
AUBERT, C ;
COASSOLO, P ;
CANO, JP .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (02) :295-311
[3]   SIMULTANEOUS SCREENING AND QUANTITATION OF ALPIDEM, ZOLPIDEM, BUSPIRONE AND BENZODIAZEPINES BY DUAL-CHANNEL GAS-CHROMATOGRAPHY USING ELECTRON-CAPTURE AND NITROGEN-PHOSPHORUS DETECTION AFTER SOLID-PHASE EXTRACTION [J].
GAILLARD, Y ;
GAYMONTCHAMP, JP ;
OLLAGNIER, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 622 (02) :197-208
[4]   DETERMINATION OF BROXATEROL IN PLASMA BY COUPLED HPLC-GC [J].
GIANESELLO, V ;
BOLZANI, L ;
BRENN, E ;
GAZZANIGA, A .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (01) :99-102
[5]  
GIANSELLO V, 1988, J CHROMATOGR, V473, P343
[7]   DETERMINATION OF THE TOTAL CONCENTRATION OF HIGHLY PROTEIN-BOUND DRUGS IN PLASMA BY ONLINE DIALYSIS AND COLUMN LIQUID-CHROMATOGRAPHY - APPLICATION TO NONSTEROIDAL ANTIINFLAMMATORY DRUGS [J].
HERRAEZHERNANDEZ, R ;
VANDEMERBEL, NC ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01) :127-137
[8]   AUTOMATED SAMPLE PREPARATION BY ONLINE DIALYSIS AND TRACE ENRICHMENT - ANALYSIS OF MORPHINE, 6-MONOACETYLMORPHINE, CODEINE, ETHYLMORPHINE AND PHOLCODINE IN PLASMA AND WHOLE-BLOOD BY CAPILLARY GAS-CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KROGH, M ;
CHRISTOPHERSEN, AS ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 621 (01) :41-48
[9]  
LILLSUNDE P, 1990, J CHROMATOGR, V553, P97
[10]   ONLINE AUTOMATED SAMPLE PREPARATION - CAPILLARY GAS-CHROMATOGRAPHY FOR THE ANALYSIS OF PLASMA SAMPLES [J].
LOUTER, AJH ;
VANDERWAGT, RACA ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1995, 40 (9-10) :500-506