Comparison between Modified and Unmodified Carbon Paste Electrodes for Hexavalent Chromium Determination

被引:21
作者
Hilali, Nazha [1 ]
Ghanam, Abdelghani [1 ]
Mohammadi, Hasna [1 ]
Amine, Aziz [1 ]
Jose Garcia-Guzman, Juan [2 ]
Cubillana-Aguilera, Laura [2 ]
Maria Palacios-Santander, Jose [2 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech, Lab Genie Proc & Environm, BP 146, Mohammadia 20800, Morocco
[2] Univ Cadiz, Dept Analyt Chem, Fac Sci, Inst Res Electron Microscopy & Mat IMEYMAT,Campus, Campus Univ Puerto Real,Polgono Rio San Pedro S-N, Cadiz 11510, Spain
关键词
Carbon paste electrodes; Diphenylcarbazide; Gold nanoparticles; Hexavalent chromium; Speciation; STRIPPING VOLTAMMETRIC MEASUREMENTS; SOLID-PHASE EXTRACTION; GOLD NANOPARTICLES; ELECTROCHEMICAL DETECTION; WATER SAMPLES; CR(VI); SPECIATION; IONS; INTERFERENCES; NANOCOMPOSITE;
D O I
10.1002/elan.201800505
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work consists of developing a simple electroanalytical method which allows the speciation of Cr(VI). Gold modified Carbon Paste Electrodes (CPEs) and unmodified CPEs have been tested for the determination of Cr(VI) in presence of an excess of Cr(III) by using differential pulse voltammetry (DPV), without any accumulation or pre-concentration time. Several parameters affecting the analytical performances of the designed electrodes were investigated, including: electrodeposition technique of AuNPs onto the CPE, amount of AuNPs dropped on the electrode surface, supporting electrolyte, presence of Cr(III), presence of chloride ions and concentration of diphenylcarbazide (DPC). Under the optimal conditions, the use of unmodified CPE in an acidic medium containing DPC exhibited a high selectivity and a good detection limit of 19 mu g L-1, which is much lower than the admissible concentration fixed by the World Health Organization (50 mu g.L-1). A linear range from 50 to 260 mu g.L-1 was obtained with a relative standard deviation of 7.75 %. Furthermore, as opposed to the AuNPs-modified CPE, the current response of Cr(VI) obtained at the unmodified CPE was not affected by the presence of chloride ions and trivalent chromium. Finally, the proposed method was successfully applied for the determination of Cr(VI) in real tap water samples with satisfactory results.
引用
收藏
页码:2750 / 2759
页数:10
相关论文
共 50 条
  • [31] Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method
    Miyake, Yuichi
    Tokumura, Masahiro
    Iwazaki, Yuta
    Wang, Qi
    Amagai, Takashi
    Horii, Yuichi
    Otsuka, Hideyuki
    Tanikawa, Noboru
    Kobayashi, Takeshi
    Oguchi, Masahiro
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1502 : 24 - 29
  • [32] Hyperbranched Polyethylenimine Modified Waste Fiberboard Activated Carbon for Enhanced Adsorption of Hexavalent Chromium
    Pan, Rongrong
    Zou, Jixin
    Li, Yue
    Jin, Xiaojuan
    JOURNAL OF WOOD CHEMISTRY AND TECHNOLOGY, 2018, 38 (02) : 111 - 122
  • [33] Multi-walled carbon nanotube and nanosilica chemically modified carbon paste electrodes for the determination of mercury(II) in polluted water samples
    Ali, Tamer Awad
    Mohamed, Gehad G.
    ANALYTICAL METHODS, 2015, 7 (15) : 6280 - 6289
  • [34] Cyclodextrin modified carbon paste based electrodes as sensors for the determination of carcinogenic polycyclic aromatic amines
    Ferancová, A
    Korgová, E
    Labuda, J
    Zima, J
    Barek, J
    ELECTROANALYSIS, 2002, 14 (23) : 1668 - 1673
  • [35] Carbon paste electrodes modified with biosolids, soils and biocomposites utilized to study the interaction between organic matter and copper
    Flores-Alvarez, J. M.
    Gonzalez, I.
    Garcia-de la Rosa, L. A.
    Mancilla-Pena, F.
    Reyes-Gomez, J.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2011, 92 (03) : 448 - 456
  • [36] Electrochemical and spectroelectrochemical investigations of quercetin on unmodified and DNA-modified carbon paste electrode and its determination using voltammetry
    Satpati, A. K.
    Sahoo, S.
    Dey, M. K.
    Reddy, A. V. R.
    Mukherjee, T.
    ANALYTICAL METHODS, 2011, 3 (06) : 1344 - 1350
  • [37] Determination of trace amounts of hexavalent chromium in drinking waters by dispersive microsolid-phase extraction using modified multiwalled carbon nanotubes combined with total reflection X-ray fluorescence spectrometry
    Bahadir, Z.
    Bulut, V. N.
    Hidalgo, M.
    Soylak, M.
    Margui, E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 107 : 170 - 177
  • [38] Electrochemical determination of chromium(VI) using metallic nanoparticle-modified carbon screen-printed electrodes
    Dominguez-Renedo, Olga
    Ruiz-Espelt, Laura
    Garcia-Astorgano, Natalia
    Julia Arcos-Martinez, M.
    TALANTA, 2008, 76 (04) : 854 - 858
  • [39] Novel sensor based on carbon paste/NafionA® modified with gold nanoparticles for the determination of glutathione
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (6-7) : 1661 - 1672
  • [40] Stabilization/solidification of hexavalent chromium containing tailings using low-carbon binders for cemented paste backfill
    Zhang, Shiyu
    Zhao, Yingliang
    Guo, Zhenbang
    Ding, Hangxing
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2021, 9 (01):