Energy and comfort performance of occupant-centric air conditioning strategy in office buildings with personal comfort devices

被引:43
作者
Zhang, Jingsi [1 ]
Zhou, Xiang [1 ]
Lei, Song [2 ]
Luo, Maohui [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
[2] China Architectural Design & Res Inst, 151 Hankou Rd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
thermal comfort; personal comfort system; occupant behavior; building energy simulation; building energy saving; THERMAL COMFORT; VENTILATION SYSTEM; BEHAVIOR; FIELD; CONSUMPTION; DESIGN; MODEL; CHAIR; HOT;
D O I
10.1007/s12273-021-0852-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
The personal comfort system (PCS) aims to meet individual thermal comfort demands efficiently to achieve higher thermal comfort satisfaction while reducing air conditioning energy consumption. To date, many PCS devices have been developed and evaluated from the perspective of thermal comfort. It will be useful for future PCS development if an approach to quantify the thermal comfort and energy performance of certain PCS devices and their combinations with consideration of user behaviors can be established. This study attempted to fill this gap by integrating thermal comfort experiments, occupancy simulations, usage behavior modeling, and building energy simulation technologies. First, human subject experiments were conducted to quantify the thermal comfort effects of the PCS. Then, the Markov chain model and conditional probability model were employed to describe the room occupancy and PCS usage behaviors. Finally, the extended comfort temperature range and user behavior models were imported into the building energy simulation tool to analyze the energy-saving potential of the PCS. The results show that the use of PCS can significantly improve occupants' thermal comfort and satisfaction rate under both warm and cool conditions. Using a cooling cushion and desktop fan can lift the upper limit of the comfortable temperature to 29.5 degrees C while the heated cushion can extend the lower limit to 15 degrees C. By increasing the air conditioning temperature setpoint by 2 degrees C in summer and reducing by 2.5 degrees C the heating temperature setpoint in winter, PCS devices can reduce heating and air conditioning energy consumption by 25%-40% while maintaining occupants' thermal comfort.
引用
收藏
页码:899 / 911
页数:13
相关论文
共 47 条
  • [1] [Anonymous], P INT C ENV ERG BOST
  • [2] [Anonymous], 2010, THERMAL ENV CONDITIO
  • [3] Bauman F., 2017, Changing the Rules: Innovative low-energy occupant-responsive HVAC controls and systems. Final report to the California Energy Commission
  • [4] Center B.P., 2020, Annual energy outlook 2020, V12, P1672
  • [5] Chilled ceiling and displacement ventilation aided with personalized evaporative cooler
    Chakroun, W.
    Ghaddar, N.
    Ghali, K.
    [J]. ENERGY AND BUILDINGS, 2011, 43 (11) : 3250 - 3257
  • [6] Statistical analysis and modeling of occupancy patterns in open-plan offices using measured lighting-switch data
    Chang, Wen-Kuei
    Hong, Tianzhen
    [J]. BUILDING SIMULATION, 2013, 6 (01) : 23 - 32
  • [7] Effect of thermostat and window opening occupant behavior models on energy use in homes
    D'Oca, Simona
    Fabi, Valentina
    Corgnati, Stefano P.
    Andersen, Rune Korsholm
    [J]. BUILDING SIMULATION, 2014, 7 (06) : 683 - 694
  • [8] Review on occupancy detection and prediction in building simulation
    Ding, Yan
    Han, Shuxue
    Tian, Zhe
    Yao, Jian
    Chen, Wanyue
    Zhang, Qiang
    [J]. BUILDING SIMULATION, 2022, 15 (03) : 333 - 356
  • [9] DOE, 2011, QUADRENNIAL TECHNOLO
  • [10] Modeling occupancy and behavior for better building design and operation-A critical review
    Dong, Bing
    Yan, Da
    Li, Zhaoxuan
    Jin, Yuan
    Feng, Xiaohang
    Fontenot, Hannah
    [J]. BUILDING SIMULATION, 2018, 11 (05) : 899 - 921