Simultaneous Estimation of Escitalopram and Clonazepam in Tablet Dosage Forms Using HPLC-DAD Method and Optimization of Chromatographic Conditions by Box-Behnken Design

被引:7
作者
Foudah, Ahmed, I [1 ]
Alshehri, Sultan [2 ]
Shakeel, Faiyaz [3 ]
Alqarni, Mohammed H. [1 ]
Aljarba, Tariq M. [1 ]
Alam, Prawez [1 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Pharm, Dept Pharmacognosy, Al Kharj 11942, Saudi Arabia
[2] AlMaarefa Univ, Coll Pharm, Dept Pharmaceut Sci, Ad Diriyah 13713, Saudi Arabia
[3] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
来源
MOLECULES | 2022年 / 27卷 / 13期
关键词
Box-Behnken design; RP-HPLC; ICH guidelines; stability studies; assay; SPECTROPHOTOMETRIC METHOD; RP-HPLC; VALIDATION; STABILITY; QUALITY; OXALATE;
D O I
10.3390/molecules27134209
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The study aimed to develop a new reverse-phase high-performance liquid chromatography (RP-HPLC) method with diode array detection (DAD) detection for simultaneous estimation of escitalopram (EST) and clonazepam (CZP) in tablet dosage forms with a quality by design (QbD) approach. The chromatographic conditions were optimized by Box-Behnken design (BBD) and developed method was validated for the linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability according to International Council for Harmonization (ICH) guidelines. EST and CZP standard drugs peaks were separated at retention times of 2.668 and 5.046 min by C-18 column with dimension of 4.6 x 100 mm length and particle size packing 2.5 mu m. The mobile phase was methanol: 0.1% orthophosphoric acid (OPA) (25:75, v/v), with a flow rate of 0.7 mL/min at temperature of 26 degrees C. The sample volume injected was 20 mu L and peaks were detected at 239 nm. Using the standard calibration curve, the % assay of marketed tablet was founded 98.89 and 98.76 for EST and CZP, respectively. The proposed RP-HPLC method was able to detect EST and CZP in the presence of their degradation products, indicating the stability-indicating property of the developed RP-HPLC method. The validation parameter's results in terms of linearity, system suitability, accuracy, precision, robustness, sensitivity, and solution stability were in an acceptable range as per the ICH guidelines. The newly developed RP-HPLC method with QbD application is simple, accurate, time-saving, and economic.
引用
收藏
页数:16
相关论文
共 38 条
  • [1] Development and validation of a simple reversed-phase HPLC-UV method for determination of oleuropein in olive leaves
    Al-Rimawi, Fuad
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (03) : 285 - 289
  • [2] Ali S., 2016, Int. J. Pharm. Chem, V6, P62
  • [3] Development and validation of a new HPLC analytical method for the determination of diclofenac in tablets
    Alquadeib, Bushra Tuwfeeq
    [J]. SAUDI PHARMACEUTICAL JOURNAL, 2019, 27 (01) : 66 - 70
  • [4] [Anonymous], 2018, FINAL CONCEPT PAPER
  • [5] [Anonymous], ICH Q2 R2 VALIDATION
  • [6] Awni Kamal J., 2020, IOP Conference Series: Earth and Environmental Science, V553, DOI 10.1088/1755-1315/553/1/012020
  • [7] Bairagi S.H., 2020, INT J PHARM PHARM SC, V12, P55, DOI [10.22159/ijpps.2020v12i8.37964, DOI 10.22159/IJPPS.2020V12I8.37964]
  • [8] Development and Validation of a Stability-Indicating Liquid Chromatographic Method for Estimating Olmesartan Medoxomil Using Quality by Design
    Beg, Sarwar
    Sharma, Gajanand
    Katare, O. P.
    Lohan, Shikha
    Singh, Bhupinder
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (07) : 1048 - 1059
  • [9] Bhimanadhuni C.N., 2012, International Current Pharmaceutical Journal, V1, P193, DOI DOI 10.3329/ICPJ.V1I8.11249
  • [10] Escitalopram - A review of its use in the management of anxiety disorders
    Dhillon, Sohita
    Scott, Lesley J.
    Plosker, Greg L.
    [J]. CNS DRUGS, 2006, 20 (09) : 763 - 790