How to Build a Patient-Specific Hybrid Simulator for Orthopaedic Open Surgery: Benefits and Limits of Mixed-Reality Using the Microsoft HoloLens

被引:106
作者
Condino, Sara [1 ,2 ]
Turini, Giuseppe [3 ]
Parchi, Paolo D. [1 ,4 ]
Viglialoro, Rosanna M. [1 ]
Piolanti, Nicola [4 ]
Gesi, Marco [5 ,6 ]
Ferrari, Mauro [1 ]
Ferrari, Vincenzo [1 ,2 ]
机构
[1] Univ Pisa, Dept Translat Res & New Surg & Med Technol, EndoCAS Ctr, I-56124 Pisa, PI, Italy
[2] Univ Pisa, Dept Informat Engn, I-56124 Pisa, PI, Italy
[3] Kettering Univ, Dept Comp Sci Dept, Flint, MI 48504 USA
[4] Univ Pisa, Dept Translat Res & New Surg & Med Technol, Orthopaed & Traumatol Div 1, I-56124 Pisa, PI, Italy
[5] Univ Pisa, Dept Translat Res & New Surg & Med Technol, I-56124 Pisa, PI, Italy
[6] Univ Pisa, Ctr Rehabil Med Sport & Anat, I-56124 Pisa, PI, Italy
关键词
VERGENCE-ACCOMMODATION CONFLICT; MOUNTED DISPLAYS; FEMUR; TOOL;
D O I
10.1155/2018/5435097
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Orthopaedic simulators are popular in innovative surgical training programs, where trainees gain procedural experience in a safe and controlled environment. Recent studies suggest that an ideal simulator should combine haptic, visual, and audio technology to create an immersive training environment. This article explores the potentialities of mixed-reality using the HoloLens to develop a hybrid training system for orthopaedic open surgery. Hip arthroplasty, one of the most common orthopaedic procedures, was chosen as a benchmark to evaluate the proposed system. Patient-specific anatomical 3D models were extracted from a patient computed tomography to implement the virtual content and to fabricate the physical components of the simulator. Rapid prototyping was used to create synthetic bones. The Vuforia SDK was utilized to register virtual and physical contents. The Unity3D game engine was employed to develop the software allowing interactions with the virtual content using head movements, gestures, and voice commands. Quantitative tests were performed to estimate the accuracy of the system by evaluating the perceived position of augmented reality targets. Mean and maximum errors matched the requirements of the target application. Qualitative tests were carried out to evaluate workload and usability of the HoloLens for our orthopaedic simulator, considering visual and audio perception and interaction and ergonomics issues. The perceived overall workload was low, and the self-assessed performance was considered satisfactory. Visual and audio perception and gesture and voice interactions obtained a positive feedback. Postural discomfort and visual fatigue obtained a nonnegative evaluation for a simulation session of 40 minutes. These results encourage using mixed-reality to implement a hybrid simulator for orthopaedic open surgery. An optimal design of the simulation tasks and equipment setup is required to minimize the user discomfort. Future works will include Face Validity, Content Validity, and Construct Validity to complete the assessment of the hip arthroplasty simulator.
引用
收藏
页数:12
相关论文
共 44 条
  • [1] LEAST-SQUARES FITTING OF 2 3-D POINT SETS
    ARUN, KS
    HUANG, TS
    BLOSTEIN, SD
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) : 699 - 700
  • [2] Barfield W., 2001, Fundamentals of wearable computers and aug- mented reality
  • [3] Blender Foundation, 2020, BLEND FREE OP SOURC
  • [4] What is going on in augmented reality simulation in laparoscopic surgery?
    Botden, Sanne M. B. I.
    Jakimowicz, Jack J.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2009, 23 (08): : 1693 - 1700
  • [5] Carbone M., 2011, CEUR WORKSHOP P, P13
  • [6] Proof of Concept: Wearable Augmented Reality Video See-Through Display for Neuro-Endoscopy
    Carbone, Marina
    Condino, Sara
    Cutolo, Fabrizio
    Viglialoro, Rosanna Maria
    Kaschke, Oliver
    Thomale, Ulrich W.
    Ferrari, Vincenzo
    [J]. AUGMENTED REALITY, VIRTUAL REALITY, AND COMPUTER GRAPHICS, AVR 2018, PT II, 2018, 10851 : 95 - 104
  • [7] Carbone M, 2012, IEEE ENG MED BIO, P492, DOI 10.1109/EMBC.2012.6345975
  • [8] Fatigue performance of composite analogue femur constructs under high activity loading
    Chong, Alexander C. M.
    Friis, Elizabeth A.
    Ballard, Gregory P.
    Czuwala, Peter J.
    Cooke, Francis W.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (07) : 1196 - 1205
  • [9] Cignoni P., 2008, EUROGRAPHICS ITALIAN
  • [10] How to build patient-specific synthetic abdominal anatomies. An innovative approach from physical toward hybrid surgical simulators
    Condino, S.
    Carbone, M.
    Ferrari, V.
    Faggioni, L.
    Peri, A.
    Ferrari, M.
    Mosca, F.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2011, 7 (02) : 202 - 213