High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography

被引:83
作者
Fain, SB [1 ]
King, BF [1 ]
Breen, JF [1 ]
Kruger, DG [1 ]
Riederer, SJ [1 ]
机构
[1] Mayo Clin, Magnet Resonance Lab, Rochester, MN 55905 USA
关键词
magnetic resonance (MR); contrast media; rapid imaging; vascular studies; renal angiography; renal arteries; MR; stenosis or obstruction;
D O I
10.1148/radiology.218.2.r01fe36481
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a high-spatial-resolution three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiographic technique for detecting proximal and distal renal arterial stenosis. MATERIALS AND METHODS: Twenty-five patients underwent high-spatial-resolution small-field-of-view (FOV) 3D contrast-enhanced MR angiography of the renal arteries, which was followed several minutes later by more standard, large-FOV 3D contrast-enhanced MR angiography that included the distal aorta and iliac arteries. For both acquisitions, MR fluoroscopic triggering and an elliptic centric view order were used. Two readers evaluated the MR angiograms for grade and hemodynamic significance of renal arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of digital subtraction angiograms. RESULTS: The high-spatial-resolution small-FOV technique provided high sensitivity (97%) and specificity (92%) for the detection of renal arterial stenosis, including all four distal stenoses encountered. The portrayal of the segmental renal arteries was adequate for diagnosis in 19 (76%) of 25 patients. In 12% of the patients, impaired depiction of the segmental arteries was linked to motion. CONCLUSION: The combined high-spatial-resolution small-FOV and large-FOV MR angiographic examination provides improved spatial resolution in the region of the renal arteries while maintaining coverage of the abdominal aorta and iliac arteries.
引用
收藏
页码:481 / 490
页数:10
相关论文
共 30 条
  • [21] Evaluation of renal artery stenosis with dynamic gadolinium-enhanced MR angiography
    Rieumont, MJ
    Kaufman, JA
    Geller, SC
    Yucel, EK
    Cambria, RP
    Fang, LST
    Bazari, H
    Waltman, AC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 39 - 44
  • [22] ROSNER B, 1995, FUNDAMENTALS BIOSTAT, P575
  • [23] Renal artery stenosis: Grading of hemodynamic changes with cine phase-contrast MR blood flow measurements
    Schoenberg, SO
    Knopp, MV
    Bock, M
    Kallinowski, F
    Just, A
    Essig, M
    Hawighorst, H
    Schad, L
    vanKaick, G
    [J]. RADIOLOGY, 1997, 203 (01) : 45 - 53
  • [24] Renal arteries: Optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold
    Schoenberg, SO
    Bock, M
    Knopp, MV
    Essig, M
    Laub, G
    Hawighorst, H
    Zuna, I
    Kallinowski, F
    van Kaick, G
    [J]. RADIOLOGY, 1999, 211 (03) : 667 - 679
  • [26] Three-dimensional gadolinium-enhanced MR angiography for aortoiliac inflow assessment plus renal artery screening in a single breath hold
    Snidow, JJ
    Johnson, MS
    Harris, VJ
    Margosian, PM
    Aisen, AM
    Lalka, SG
    Cikrit, DF
    Trerotola, SO
    [J]. RADIOLOGY, 1996, 198 (03) : 725 - 732
  • [27] Contrast-enhanced, K-space-centered, breath-hold MR angiography of the renal arteries and the abdominal aorta
    Steffens, JC
    Link, J
    Grassner, J
    MuellerHuelsbeck, S
    Brinkmann, G
    Reuter, M
    Heller, M
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04) : 617 - 622
  • [28] Performance of an elliptical centric view order for signal enhancement and motion artifact suppression in breath-hold three-dimensional gradient echo imaging
    Wilman, AH
    Riederer, SJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) : 793 - 802
  • [29] Fluoroscopically triggered contrast-enhanced three-dimensional MR angiography with elliptical centric view order: Application to the renal arteries
    Wilman, AH
    Riederer, SJ
    King, BF
    Debbins, JP
    Rossman, PJ
    Ehman, RL
    [J]. RADIOLOGY, 1997, 205 (01) : 137 - 146
  • [30] SPOILING OF TRANSVERSE MAGNETIZATION IN STEADY-STATE SEQUENCES
    ZUR, Y
    WOOD, ML
    NEURINGER, LJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) : 251 - 263