High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography

被引:83
作者
Fain, SB [1 ]
King, BF [1 ]
Breen, JF [1 ]
Kruger, DG [1 ]
Riederer, SJ [1 ]
机构
[1] Mayo Clin, Magnet Resonance Lab, Rochester, MN 55905 USA
关键词
magnetic resonance (MR); contrast media; rapid imaging; vascular studies; renal angiography; renal arteries; MR; stenosis or obstruction;
D O I
10.1148/radiology.218.2.r01fe36481
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate a high-spatial-resolution three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiographic technique for detecting proximal and distal renal arterial stenosis. MATERIALS AND METHODS: Twenty-five patients underwent high-spatial-resolution small-field-of-view (FOV) 3D contrast-enhanced MR angiography of the renal arteries, which was followed several minutes later by more standard, large-FOV 3D contrast-enhanced MR angiography that included the distal aorta and iliac arteries. For both acquisitions, MR fluoroscopic triggering and an elliptic centric view order were used. Two readers evaluated the MR angiograms for grade and hemodynamic significance of renal arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of digital subtraction angiograms. RESULTS: The high-spatial-resolution small-FOV technique provided high sensitivity (97%) and specificity (92%) for the detection of renal arterial stenosis, including all four distal stenoses encountered. The portrayal of the segmental renal arteries was adequate for diagnosis in 19 (76%) of 25 patients. In 12% of the patients, impaired depiction of the segmental arteries was linked to motion. CONCLUSION: The combined high-spatial-resolution small-FOV and large-FOV MR angiographic examination provides improved spatial resolution in the region of the renal arteries while maintaining coverage of the abdominal aorta and iliac arteries.
引用
收藏
页码:481 / 490
页数:10
相关论文
共 30 条
  • [1] Renal artery stenosis and accessory renal arteries:: Accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography
    Bakker, J
    Beek, FJA
    Beutler, JJ
    Hené, RJ
    de Kort, GAP
    de Lange, EE
    Moons, KGM
    Mali, WPTM
    [J]. RADIOLOGY, 1998, 207 (02) : 497 - 504
  • [2] Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Mellone, R
    Angeli, E
    Venturini, M
    Garancini, MP
    Quartagno, R
    Bianchi, G
    DelMaschio, A
    [J]. RADIOLOGY, 1997, 205 (03) : 689 - 695
  • [3] Diagnosis of renal vascular disease with MR angiography
    Dong, Q
    Schoenberg, SO
    Carlos, RC
    Neimatallah, M
    Cho, KJ
    Williams, DM
    Kazanjian, SN
    Prince, MR
    [J]. RADIOGRAPHICS, 1999, 19 (06) : 1535 - 1554
  • [4] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [5] Fain SB, 1999, MAGNET RESON MED, V42, P1106, DOI 10.1002/(SICI)1522-2594(199912)42:6<1106::AID-MRM15>3.0.CO
  • [6] 2-Q
  • [7] Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography
    Foo, TKF
    Saranathan, M
    Prince, MR
    Chenevert, TL
    [J]. RADIOLOGY, 1997, 203 (01) : 275 - 280
  • [8] Renal artery stenosis: Evaluation with conventional angiography versus gadolinium-enhanced MR angiography
    Gilfeather, M
    Yoon, HC
    Siegelman, ES
    Axel, L
    Stolpen, AH
    Shlansky-Goldberg, RD
    Baum, RA
    Soulen, MC
    Schnall, MD
    [J]. RADIOLOGY, 1999, 210 (02) : 367 - 372
  • [9] GRIST TM, 1993, P 12 ANN SCI M SOC M, P187
  • [10] Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography
    Hany, TF
    Debatin, JF
    Leung, DA
    Pfammatter, T
    [J]. RADIOLOGY, 1997, 204 (02) : 357 - 362