Fine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma

被引:77
作者
Bisgaard, H [1 ]
Klug, B
Sumby, BS
Burnell, PKP
机构
[1] Rigshosp, Natl Univ Hosp, Dept Paediat, Pulm Serv, DK-2100 Copenhagen, Denmark
[2] Glaxo Wellcome Res & Dev Ltd, Ware, Herts, England
关键词
aerosol; children; Diskus; dry powder inhaler; inspiratory flow; Turbuhaler;
D O I
10.1183/09031936.98.11051111
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The study aimed to investigate dose consistency and particle distribution from the dry powder inhalers Diskus and Turbuhaler. Full profiles of inhalation pressure versus time were recorded in 18 4 gr old and 18 8 yr old asthmatic children through Diskus and Turbuhaler inhalers, These data mere used in an inhalation profile simulator to assess drug delivery from both a Diskus inhaler and a Turbuhaler inhaler, and in particular to assess the proportion of drug emitted in the coarse (>4.7 mu m) and fine (<4.7 mu m) particle size range from each type of inhaler. The inhalation profile more accurately represents the changes in flow rate over time through the device than the constant Bow rate usually applied with an impactor alone. The aerosol cloud was released before the peak inspiratory effort had been achieved and accordingly the early part and not the peak of the inspiratory performance is a determinant of the quality of the aerosol. The mean (SD) amount of drug in large particles (>4.7 mu m), fine particles (<4.7 mu m) and very fine particles (<2.1 mu m) in percentage of label claim from the Fluticasone Diskus was 72 (5), 15 (2) and 2 (1) from the 4 Sr old children and 71 (3), 18 (2) and 2 (1) from the 8 yr old children, respectively. Similar particle fractions from the Budesonide Turbuhaler were 35 (9), 21 (10) and 7 (5) from 4 yr old children and 30 (7), 32 (9) and 12 (6) from 8 yr old children. In conclusion, the Diskus inhaler provides an improved dose consistency through the varying age groups and inspiratory flow performances when compared to the Turbuhaler in terms of the proportion of the dose emitted at each particle size, This improvement is at the expense of a low fine particle mass and a high proportion of coarse particles from the Diskus as compared with the Turbuhaler.
引用
收藏
页码:1111 / 1115
页数:5
相关论文
共 50 条
  • [21] Clinical effect of Diskus™ dry-powder inhaler at low and high inspiratory flow-rates in asthmatic children
    Nielsen, KG
    Auk, IL
    Bojsen, K
    Ifversen, M
    Klug, B
    Bisgaard, H
    EUROPEAN RESPIRATORY JOURNAL, 1998, 11 (02) : 350 - 354
  • [22] Efficacy and tolerability of beclomethasone dipropionate delivered by a novel multidose dry powder inhaler (Clickhaler®) versus a metered-dose inhaler in children with asthma
    Adler, LM
    Anand, C
    Wright, FGD
    Barrett, CF
    McKeith, D
    Clark, WIC
    Maksimczyk, P
    Martin, GDR
    McKinnon, C
    Raffles, AKM
    Buck, H
    CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 2001, 62 (11): : 758 - 769
  • [23] PEAK INSPIRATORY FLOW AND INSPIRATORY VITAL CAPACITY OF PATIENTS WITH ASTHMA MEASURED WITH AND WITHOUT A NEW DRY-POWDER INHALER DEVICE (TURBUHALER)
    ENGEL, T
    HEINIG, JH
    MADSEN, F
    NIKANDER, K
    EUROPEAN RESPIRATORY JOURNAL, 1990, 3 (09) : 1037 - 1041
  • [24] Delivery of Medications by Metered Dose Inhaler Through a Chamber/Mask to Young Children with Asthma
    ElMallah, Mai K.
    Hendeles, Leslie
    PEDIATRIC ALLERGY IMMUNOLOGY AND PULMONOLOGY, 2012, 25 (04) : 236 - 239
  • [25] Selecting an accessory device with a metered-dose inhaler: Variable influence of accessory devices on fine particle dose, throat deposition, and drug delivery with asynchronous actuation from a metered-dose inhaler
    Wilkes, W
    Fink, J
    Dhand, R
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (03): : 351 - 360
  • [26] Pharmacokinetics and Pharmacodynamics of Fluticasone Propionate and Salmeterol Delivered as a Combination Dry Powder from a Capsule-Based Inhaler and a Multidose Inhaler in Asthma and COPD Patients
    Daley-Yates, Peter T.
    Mehta, Rashmi
    Chan, Robert H.
    Despa, Simona X.
    Louey, Margaret D.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2014, 27 (04) : 279 - 289
  • [27] Metered dose inhaler-spacer use education effects on achieve asthma control in children
    Turkeli, Ahmet
    Yilmaz, Ozge
    Yuksel, Hasan
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2016, 64 (02): : 105 - 111
  • [28] Resource utilization with fluticasone propionate and salmeterol in a single inhaler compared with other controller therapies in children with asthma
    Stempel, DA
    Riedel, AA
    Rosenzweig, JRC
    CURRENT MEDICAL RESEARCH AND OPINION, 2006, 22 (03) : 463 - 470
  • [29] Combination fixed-dose beta agonist and steroid inhaler as required for adults or children with mild asthma
    Crossingham, Iain
    Turner, Sally
    Ramakrishnan, Sanjay
    Fries, Anastasia
    Gowell, Matthew
    Yasmin, Farhat
    Richardson, Rebekah
    Webb, Philip
    O'Boyle, Emily
    Hinks, Timothy S. C.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2021, (05):
  • [30] Appropriate inhaler use in children with asthma: barriers and opportunities through the lens of the socio-ecological model
    Bickel, Scott
    Cohen, Robyn T.
    Needleman, Joshua P.
    Volerman, Anna
    JOURNAL OF ASTHMA, 2023, 60 (07) : 1269 - 1279