Fine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma

被引:80
作者
Bisgaard, H [1 ]
Klug, B
Sumby, BS
Burnell, PKP
机构
[1] Rigshosp, Natl Univ Hosp, Dept Paediat, Pulm Serv, DK-2100 Copenhagen, Denmark
[2] Glaxo Wellcome Res & Dev Ltd, Ware, Herts, England
关键词
aerosol; children; Diskus; dry powder inhaler; inspiratory flow; Turbuhaler;
D O I
10.1183/09031936.98.11051111
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The study aimed to investigate dose consistency and particle distribution from the dry powder inhalers Diskus and Turbuhaler. Full profiles of inhalation pressure versus time were recorded in 18 4 gr old and 18 8 yr old asthmatic children through Diskus and Turbuhaler inhalers, These data mere used in an inhalation profile simulator to assess drug delivery from both a Diskus inhaler and a Turbuhaler inhaler, and in particular to assess the proportion of drug emitted in the coarse (>4.7 mu m) and fine (<4.7 mu m) particle size range from each type of inhaler. The inhalation profile more accurately represents the changes in flow rate over time through the device than the constant Bow rate usually applied with an impactor alone. The aerosol cloud was released before the peak inspiratory effort had been achieved and accordingly the early part and not the peak of the inspiratory performance is a determinant of the quality of the aerosol. The mean (SD) amount of drug in large particles (>4.7 mu m), fine particles (<4.7 mu m) and very fine particles (<2.1 mu m) in percentage of label claim from the Fluticasone Diskus was 72 (5), 15 (2) and 2 (1) from the 4 Sr old children and 71 (3), 18 (2) and 2 (1) from the 8 yr old children, respectively. Similar particle fractions from the Budesonide Turbuhaler were 35 (9), 21 (10) and 7 (5) from 4 yr old children and 30 (7), 32 (9) and 12 (6) from 8 yr old children. In conclusion, the Diskus inhaler provides an improved dose consistency through the varying age groups and inspiratory flow performances when compared to the Turbuhaler in terms of the proportion of the dose emitted at each particle size, This improvement is at the expense of a low fine particle mass and a high proportion of coarse particles from the Diskus as compared with the Turbuhaler.
引用
收藏
页码:1111 / 1115
页数:5
相关论文
共 10 条
[1]   Delivery of inhaled medication to children [J].
Bisgaard, H .
JOURNAL OF ASTHMA, 1997, 34 (06) :443-467
[2]  
Bisgaard H, 1996, BMJ-BRIT MED J, V313, P895
[3]   TOTAL AND REGIONAL LUNG DEPOSITION OF TERBUTALINE SULFATE INHALED VIA A PRESSURIZED MDI OR VIA TURBUHALER (R) [J].
BORGSTROM, L ;
NEWMAN, S .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1993, 97 (1-3) :47-53
[4]   LUNG DEPOSITION OF BUDESONIDE INHALED VIA TURBUHALER(R) - A COMPARISON WITH TERBUTALINE SULFATE IN NORMAL SUBJECTS [J].
BORGSTROM, L ;
BONDESSON, E ;
MOREN, F ;
TROFAST, E ;
NEWMAN, SP .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (01) :69-73
[5]   THE CHARACTERIZATION OF INHALATION DEVICES BY AN INHALATION SIMULATOR - THE ELECTRONIC LUNG [J].
BRINDLEY, A ;
SUMBY, BS ;
SMITH, IJ .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1994, 7 (02) :197-200
[6]  
BRINDLEY A, 1994, PHARM TECH EUROPE, V7, P14
[7]   EFFECT OF DIFFERENT MODES OF INHALATION ON DRUG-DELIVERY FROM A DRY POWDER INHALER [J].
NEWMAN, SP ;
HOLLINGWORTH, A ;
CLARK, AR .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1994, 102 (1-3) :127-132
[8]   TERBUTALINE SULFATE TURBUHALER - EFFECT OF INHALED FLOW-RATE ON DRUG DEPOSITION AND EFFICACY [J].
NEWMAN, SP ;
MOREN, F ;
TROFAST, E ;
TALAEE, N ;
CLARKE, SW .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1991, 74 (2-3) :209-213
[9]   CRITICAL ASPECTS OF THE FUNCTION OF INSPIRATORY FLOW DRIVEN INHALERS [J].
OLSSON, B ;
ASKING, L .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1994, 7 :S43-S47
[10]   LUNG DEPOSITION OF BUDESONIDE FROM TURBUHALER(R) IS TWICE THAT FROM A PRESSURIZED METERED-DOSE INHALER P-MDI [J].
THORSSON, L ;
EDSBACKER, S ;
CONRADSON, TB .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (10) :1839-1844