Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy

被引:3
|
作者
Korpics, Mark [1 ]
Johnson, Paul [1 ]
Patel, Rakesh [1 ]
Surucu, Murat [1 ]
Choi, Mehee [1 ]
Emami, Bahman [1 ]
Roeske, John C. [1 ]
机构
[1] Loyola Univ, Med Ctr, Dept Radiat Oncol, 2160 S First Ave,Maguire Suite 2944, Maywood, IL 60137 USA
关键词
head and neck cancer; artifact reduction; CT; image-guided RT; adaptive RT; GUIDED RADIATION-THERAPY; ITERATIVE RECONSTRUCTION; CT; IMAGE; ALGORITHM; SEGMENTATION; LOCALIZATION;
D O I
10.1177/1533034615618319
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate a method for reducing metal artifacts, arising from dental fillings, on cone-beam computed tomography images. Materials and Methods: A projection interpolation algorithm is applied to cone-beam computed tomography images containing metal artifacts from dental fillings. This technique involves identifying metal regions in individual cone-beam computed tomography projections and interpolating the surrounding values to remove the metal from the projection data. Axial cone-beam computed tomography images are then reconstructed, resulting in a reduction in the streak artifacts produced by the metal. Both phantom and patient imaging data are used to evaluate this technique. Results: The interpolation substitution technique successfully reduced metal artifacts in all cases. Corrected images had fewer or no streak artifacts compared to their noncorrected counterparts. Quantitatively, regions of interest containing the artifacts showed reduced variance in the corrected images versus the uncorrected images. Average pixel values in regions of interest around the metal object were also closer in value to nonmetal regions after artifact reduction. Artifact correction tended to perform better on patient images with less complex metal objects versus those with multiple large dental fillings. Conclusion: The interpolation substitution is potentially an efficient and effective technique for reducing metal artifacts caused by dental fillings on cone-beam computed tomography image. This technique may be effective in reducing such artifacts in patients with head and neck cancer receiving daily image-guided radiotherapy.
引用
收藏
页码:NP88 / NP94
页数:7
相关论文
共 50 条
  • [1] Metal Artifact Reduction in Helical Cone-beam Computed Tomography
    Tang, Jie
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Cheng, Jianping
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2878 - 2881
  • [2] Developments of Metal Artifact Reduction Methods for Cone-beam Computed Tomography
    Shih, Kun-Long
    David
    Jin, Shih-Chun
    Chen, Jyh-Cheng
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [3] Observer Evaluation of a Metal Artifact Reduction Algorithm Applied to Head and Neck Cone Beam Computed Tomography Images
    Korpics, M.
    Alite, F.
    Block, A. M.
    Choi, M.
    Harkenrider, M. M.
    Solanki, A. A.
    Surucu, M.
    Roeske, J. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E663 - E663
  • [4] Cone Beam Computed Tomography for radical Head and Neck Radiotherapy
    Thornberry, D.
    McLauchlam, R.
    Gujral, D. M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [5] A computational investigation for metal artifact reduction in cone-beam X-ray computed tomography
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    2006 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES,VOLS 1-3, 2006, : 376 - +
  • [6] Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
    Lell, Michael M.
    Meyer, Esther
    Kuefner, Michael A.
    May, Matthias S.
    Raupach, Rainer
    Uder, Michael
    Kachelriess, Marc
    INVESTIGATIVE RADIOLOGY, 2012, 47 (07) : 415 - 421
  • [7] Metal artifact reduction for dental implants in kilovoltage computed tomography using megavoltage cone-beam computer tomography
    Gao, Liugang
    Sun, Hongfei
    Lin, Tao
    Sui, Jianfeng
    Ni, Xinye
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2017, 34 (05): : 730 - 737
  • [8] Utilization of tin filters for streak artifact reduction in cone-beam computed tomography
    Minsoo Chun
    Jin Hwa Choi
    Ohyun Kwon
    Hyeongmin Jin
    Sung Young Lee
    Chang Heon Choi
    Jung-in Kim
    Jong Min Park
    Journal of the Korean Physical Society, 2022, 80 : 1018 - 1027
  • [9] Utilization of tin filters for streak artifact reduction in cone-beam computed tomography
    Chun, Minsoo
    Choi, Jin Hwa
    Kwon, Ohyun
    Jin, Hyeongmin
    Lee, Sung Young
    Choi, Chang Heon
    Kim, Jung-in
    Park, Jong Min
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 80 (10) : 1018 - 1027
  • [10] Correction for the 'Black Hole' Artifact in Cone-Beam Computed Tomography
    Sun, M.
    Nagy, T.
    Oelhafen, M.
    Star-Lack, J.
    MEDICAL PHYSICS, 2010, 37 (06)