Natural convection in rhombic enclosures with isothermally heated side or bottom wall: Entropy generation analysis

被引:28
作者
Anandalakshmi, R. [1 ]
Basak, Tanmay [2 ]
机构
[1] Indian Inst Technol Guwahati, Dept Chem Engn, Gauhati 781039, India
[2] Indian Inst Technol, Dept Chem Engn, Madras 600036, Tamil Nadu, India
关键词
Entropy generation; Natural convection; Rhombic enclosures; Convective heat transfer; Irreversibilities; MIXED CONVECTION; MAGNETIC-FIELD; FLOW; REACTORS; CAVITY;
D O I
10.1016/j.euromechflu.2015.05.004
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The energy efficient convection systems can be designed by reducing exergy losses. In this context, the analysis on the entropy generation during natural convection in the fluid-filled (Prandtl number, Pr = 0.015 - 1000) rhombic enclosures with various inclination angles (phi) has been carried out for the efficient thermal processing in various applications such as the chemical reactor modeling, underground coal gasification, and nuclear reactors. The enclosure is subjected to the differential heating (case 1) and Rayleigh-Benard convection (case 2). The conduction based static solution occurs only for phi = 90 degrees and it is observed that the conduction based static solution disappears with a slight perturbation of phi at Rayleigh number, Ra >= 2 x 10(3) irrespective of Pr in case 2. The active zones of the heat transfer irreversibility (S-theta) and fluid friction irreversibility (S-psi) are found to occur near the isothermal walls for all cos irrespective of Pr in both the cases at Ra = 10(5). In addition, the active zones of S-psi are also found to occur near the adiabatic walls of the cavity for all cos irrespective of Pr in both the cases at Ra = 10(5). Also, the region between the fluid layers of primary circulation cells acts as the strong active zone of S-psi for all phi s in case 2 at lower Pr (Pr = 0.015) and Ra = 10(5). The total entropy generation (S-total) and maximum heat transfer rates ((Nu) over bar) are found to be significantly low for phi = 30 degrees in both the cases at Ra = 10(5) irrespective of Pr. Analysis of heating patterns and geometrical orientations relates the exergy to irreversibilities which establishes that the rhombic cavity (phi = 30 degrees) with the differential heating pattern may be the optimal design based on the energy efficient perspective. (C) 2015 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:27 / 44
页数:18
相关论文
共 29 条
[1]   A thermodynamic approach to the boundary layer flow system [J].
Aihara, Y .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2001, 20 (01) :47-55
[2]   Heat flow visualization analysis on natural convection in rhombic enclosures with isothermal hot side or bottom wall [J].
Anandalakshmi, R. ;
Basak, Tanmay .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2013, 41 :29-45
[3]   Analysis of Entropy Generation due to Natural Convection in Rhombic Enclosures [J].
Anandalakshmi, R. ;
Basak, Tanmay .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (23) :13169-13189
[4]   A lumped parameter core dynamics model for MTR type research reactors under natural convection regime [J].
Ardaneh, Kazem ;
Zaferanlouei, Salman .
ANNALS OF NUCLEAR ENERGY, 2013, 56 :243-250
[5]   Buoyant flow in long vertical enclosures in the presence of a strong horizontal magnetic field.: Part 2.: Finite enclosures [J].
Authié, G ;
Tagawa, T ;
Moreau, R .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2003, 22 (03) :203-220
[6]   Optimal design of thermochemical reactors based on constructal approach [J].
Azoumah, Y. ;
Neveu, P. ;
Mazet, N. .
AICHE JOURNAL, 2007, 53 (05) :1257-1266
[7]   STUDY OF ENTROPY GENERATION IN FUNDAMENTAL CONVECTIVE HEAT-TRANSFER [J].
BEJAN, A .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1979, 101 (04) :718-725
[8]  
Bejan A., 1996, Entropy Generation Minimization
[9]  
Bejan A., 1994, Entropy generation through heat and fluid flow
[10]   Analysis of the Magnetic Field Effect on Entropy Generation at Thermosolutal Convection in a Square Cavity [J].
Bouabid, Mounir ;
Hidouri, Nejib ;
Magherbi, Mourad ;
Ben Brahim, Ammar .
ENTROPY, 2011, 13 (05) :1034-1054