Feasibility Study of Pulse Width at Half Amplitude of Camera PPG for Contactless Blood Pressure Estimation

被引:10
作者
Ding, Xiaorong [1 ]
Wang, Wenjin [2 ]
Chen, Yifan [1 ]
Yang, Yumin [1 ]
Zhao, Yan [1 ]
Kong, Deyuan [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Life Sci & Technol, Chengdu, Sichuan, Peoples R China
[2] Eindhoven Univ Technol, Dept Elect Engn, Eindhoven, Netherlands
来源
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC) | 2021年
关键词
D O I
10.1109/EMBC46164.2021.9630964
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Non-contact blood pressure (BP) estimation with imaging photoplethysmogram (PPG) that can be acquired by camera is a promising alternative to cuff-based technology because of its nature of pervasive, low-cost, and being continuous. Most of the non-contact BP estimation methods are based on the principle of pulse transit time (PTT) as being used for wearable cuffless BP measurement. However, PTT-based method on the one hand requires simultaneous capture of images of multiple skin sites with the sites being at a distance from each other; and on the other hand, it can only partially reflect BP changes according to previous studies. In this paper, we propose to use a different camera PPG feature that has not yet been fully studied - pulse width at half amplitude (PWHA) for the evaluation of BP in a non-contact way. PWHA can be obtained from a single-site camera PPG, and it can indicate BP changes. The relationship of PWHA and BP was analyzed on 16 healthy subjects with BP changes induced by deep breathing and stepping exercise. The results showed that beat-to-beat PWHA can well track dynamic BP changes, and it is inversely related to BP across the sampled population and within each individual with about 80% individuals having high correlations. The findings suggest that PWHA can reflect the dynamic changes in cardiovascular characteristics and thereby BP changes, demonstrating the feasibility of imaging PWHA for non-contact BP estimation beyond the PTT method.
引用
收藏
页码:365 / 368
页数:4
相关论文
共 22 条
[1]   The relationship between the photoplethysmographic waveform and systemic vascular resistance [J].
Awad A.A. ;
Haddadin A.S. ;
Tantawy H. ;
Badr T.M. ;
Stout R.G. ;
Silverman D.G. ;
Shelley K.H. .
Journal of Clinical Monitoring and Computing, 2007, 21 (6) :365-372
[2]   Analysis of the ear pulse oximeter waveform [J].
Awad A.A. ;
Stout R.G. ;
Ghobashy M.A.M. ;
Rezkanna H.A. ;
Silverman D.G. ;
Shelley K.H. .
Journal of Clinical Monitoring and Computing, 2006, 20 (3) :175-184
[3]   Continuous Blood Pressure Measurement From Invasive to Unobtrusive: Celebration of 200th Birth Anniversary of Carl Ludwig [J].
Ding, Xiao-Rong ;
Zhao, Ni ;
Yang, Guang-Zhong ;
Pettigrew, Roderic I. ;
Lo, Benny ;
Miao, Fen ;
Li, Ye ;
Liu, Jing ;
Zhang, Yuan-Ting .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (06) :1455-1465
[4]   Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm [J].
Ding, Xiaorong ;
Zhang, Yuan-Ting .
BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (01) :37-52
[5]  
Ding XY, 2020, NATURAL LANGUAGE PROCESSING FOR MEDICAL CONVERSATIONS, P1, DOI 10.18653/v1/2020.nlpmc-1.1
[6]   Remote estimation of pulse wave features related to arterial stiffness and blood pressure using a camera [J].
Djeldjli, Djamaleddine ;
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Bereksi-Reguig, Fethi ;
Pruski, Alain .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 64
[7]   Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera [J].
Jeong, In Cheol ;
Finkelstein, Joseph .
JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (04) :1-10
[8]   Cardiovascular response to exercise [J].
Laughlin, MH .
ADVANCES IN PHYSIOLOGY EDUCATION, 1999, 22 (01) :S244-S259
[9]   An iPPG-Based Device for Pervasive Monitoring of Multi-Dimensional Cardiovascular Hemodynamics [J].
Luo, Jingjing ;
Zhen, Junjie ;
Zhou, Peng ;
Chen, Wei ;
Guo, Yuzhu .
SENSORS, 2021, 21 (03) :1-14
[10]   Determination of age-related increases in large artery stiffness by digital pulse contour analysis [J].
Millasseau, SC ;
Kelly, RP ;
Ritter, JM ;
Chowienczyk, PJ .
CLINICAL SCIENCE, 2002, 103 (04) :371-377