Integration of an RF coil and commercial field camera for ultrahigh-field MRI

被引:14
作者
Gilbert, Kyle M. [1 ,2 ]
Dubovan, Paul, I [1 ,2 ]
Gati, Joseph S. [1 ,2 ]
Menon, Ravi S. [1 ,2 ]
Baron, Corey A. [1 ,2 ]
机构
[1] Univ Western Ontario, Ctr Funct & Metab Mapping, 1151 Richmond St North, London, ON N6A 5B7, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
field monitoring; functional imaging; magnetic resonance imaging; radiofrequency coil; ultrahigh field; DIFFUSION MRI; STEADY-STATE; NMR PROBES; BRAIN; RECONSTRUCTION; COMPENSATION; FLUCTUATIONS; ARRAY; ARTIFACTS; SYSTEM;
D O I
10.1002/mrm.29130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop an RF coil with an integrated commercial field camera for ultrahigh field (7T) neuroimaging. The RF coil would operate within a head-only gradient coil and be subject to the corresponding design constraints. The RF coil can thereafter be used for subject-specific correction of k-space trajectories-notably in gradient-sensitive sequences such as single-shot spiral imaging. Methods The transmit and receive performance was evaluated before and after the integration of field probes, whereas field probes were evaluated when in an optimal configuration external to the coil and after their integration. Diffusion-weighted EPI and single-shot spiral acquisitions were employed to evaluate the efficacy of correcting higher order field perturbations and the consequent effect on image quality. Results Field probes had a negligible effect on RF-coil performance, including the transmit efficiency, transmit uniformity, and mean SNR over the brain. Modest reductions in field-probe signal lifetimes were observed, caused primarily by nonidealities in the gradient and shim fields of the head-only gradient coil at the probe positions. The field-monitoring system could correct up to second-order field perturbations in single-shot spiral imaging. Conclusion The integrated RF coil and field camera was capable of concurrent-field monitoring within a 7T head-only scanner and facilitated the subsequent correction of k-space trajectories during spiral imaging.
引用
收藏
页码:2551 / 2565
页数:15
相关论文
共 64 条
[31]   Size-optimized 32-Channel Brain Arrays for 3 T Pediatric Imaging [J].
Keil, Boris ;
Alagappan, Vijay ;
Mareyam, Azma ;
Mcnab, Jennifer A. ;
Fujimoto, Kyoko ;
Tountcheva, Veneta ;
Triantafyllou, Christina ;
Dilks, Daniel D. ;
Kanwisher, Nancy ;
Lin, Weili ;
Grant, P. Ellen ;
Wald, Lawrence L. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) :1777-1787
[32]   Image reconstruction in SNR units: A general method for SNR measurement [J].
Kellman, P ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1439-1447
[33]   An industrial design solution for integrating NMR magnetic field sensors into an MRI scanner [J].
Kennedy, Michael ;
Lee, Yoojin ;
Nagy, Zoltan .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) :833-839
[34]   Looking into the functional architecture of the brain with diffusion MRI [J].
Le Bihan, D .
NATURE REVIEWS NEUROSCIENCE, 2003, 4 (06) :469-480
[35]   Artifacts and pitfalls in diffusion MRI [J].
Le Bihan, Denis ;
Poupon, Cyril ;
Amadon, Alexis ;
Lethimonnier, Franck .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) :478-488
[36]   On the signal-to-noise ratio benefit of spiral acquisition in diffusion MRI [J].
Lee, Yoojin ;
Wilm, Bertram J. ;
Brunner, David O. ;
Gross, Simon ;
Schmid, Thomas ;
Nagy, Zoltan ;
Pruessmann, Klaas P. .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) :1924-1937
[37]   A field -monitoring -based approach for correcting eddy -current -induced artifacts of up to the 2 nd spatial order in human-connectome-project-style multiband diffusion MRI experiment at 7T: A pilot study [J].
Ma, Ruoyun ;
Akcakaya, Mehmet ;
Moeller, Steen ;
Auerbach, Edward ;
Ugurbil, Kamil ;
Van De Moortele, Pierre-Francois .
NEUROIMAGE, 2020, 216
[38]  
Mahmutovic M., 2021, Proceedings of the 29th Annual Meeting of ISMRM. Online Meeting, P623
[39]   The Human Connectome Project and beyond: Initial applications of 300 mT/m gradients [J].
McNab, Jennifer A. ;
Edlow, Brian L. ;
Witzel, Thomas ;
Huang, Susie Y. ;
Bhat, Himanshu ;
Heberlein, Keith ;
Feiweier, Thorsten ;
Liu, Kecheng ;
Keil, Boris ;
Cohen-Adad, Julien ;
Tisdall, M. Dylan ;
Folkerth, Rebecca D. ;
Kinney, Hannah C. ;
Wald, Lawrence L. .
NEUROIMAGE, 2013, 80 :234-245
[40]   Concomitant field terms for asymmetric gradient coils: Consequences for diffusion, flow, and echo-planar imaging [J].
Meier, C. ;
Zwanger, M. ;
Feiweier, T. ;
Porter, D. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) :128-134