Room HVAC Influences on the Removal of Airborne Particulate Matter: Implications for School Reopening during the COVID-19 Pandemic

被引:8
作者
Nafchi, Ali Mohammadi [1 ]
Blouin, Vincent [2 ]
Kaye, Nigel [3 ]
Metcalf, Andrew [4 ]
Van Valkinburgh, Katie
Mousavi, Ehsan [1 ]
机构
[1] Clemson Univ, Nieri Family Dept Construct Sci & Management, Clemson, SC 29634 USA
[2] Clemson Univ, Sch Architecture, Dept Mat Sci & Engn, Clemson, SC 29634 USA
[3] Clemson Univ, Glenn Dept Civil Engn, Clemson, SC 29634 USA
[4] Clemson Univ, Environm Engn & Earth Sci, Clemson, SC 29634 USA
关键词
mechanical ventilation; school reopening; COVID-19; air quality; contaminant control; HVAC; INDOOR; CONTAMINATION; TRANSMISSION; GROWTH; DESIGN; SYSTEM; DUST;
D O I
10.3390/en14227463
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
(1) Background: Many schools and higher education settings have confronted the issue of reopening their facilities after the COVID-19 pandemic. In response, several airflow strategies spanning from adding portable air purifiers to major mechanical overhauls have been suggested to equip classrooms with what is necessary to provide a safe and reliable environment. Yet, there are many unknowns about specific contributions of the building system and its design and performance on indoor air quality (IAQ) improvements. (2) Methods: this study examined the combined effect of ventilation type, airflow rates, and filtration on IAQ in five different classrooms. Experiments were conducted by releasing inert surrogate particles into the classrooms and measuring the concentrations in various locations of the room. (3) Results: we showed that while the distribution of particles in the space is a complex function of space geometry and air distribution configurations, the average decay rate of contaminants is proportional to the number of air changes per hour in the room. (4) Conclusions: rooms with a central HVAC system responded quicker to an internal source of contamination than rooms with only fan coil units. Furthermore, increasing the ventilation rate without improved filtration is an inefficient use of energy.
引用
收藏
页数:16
相关论文
共 36 条
[1]   Characteristics and health risk assessment of heavy metal contamination from dust collected on household HVAC air filters [J].
Al-Harbi, Meshari ;
Alhajri, Ibrahim ;
Whalen, Joann K. .
CHEMOSPHERE, 2021, 277
[2]   Aspergillosis in immunocompromised paediatric patients: Associations with building hygiene, design, and indoor air [J].
Anderson, K ;
Morris, G ;
Kennedy, H ;
Croall, J ;
Michie, J ;
Richardson, MD ;
Gibson, B .
THORAX, 1996, 51 (03) :256-261
[3]  
[Anonymous], 2020, Centers for Disease Control and Prevention: adult oral health
[4]   Design and Evaluation of a Reliable Low-Cost Atmospheric Pollution Station in Urban Environment [J].
Astudillo, Galo D. ;
Garza-Castanon, Luis E. ;
Minchala Avila, Luis I. .
IEEE ACCESS, 2020, 8 :51129-51144
[5]   HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs [J].
Azimi, Parham ;
Stephens, Brent .
BUILDING AND ENVIRONMENT, 2013, 70 :150-160
[6]   Particle dispersion in a cleanroom - effects of pressurization, door opening and traffic flow [J].
Bhattacharya, Arup ;
Metcalf, Andrew R. ;
Nafchi, Ali Mohammadi ;
Mousavi, Ehsan S. .
BUILDING RESEARCH AND INFORMATION, 2021, 49 (03) :294-307
[7]   Contamination of Air and Surfaces in Workplaces with SARS-CoV-2 Virus: A Systematic Review [J].
Cherrie, John W. ;
Cherrie, Mark P. C. ;
Smith, Alice ;
Holmes, David ;
Semple, Sean ;
Steinle, Susanne ;
Macdonald, Ewan ;
Moore, Ginny ;
Loh, Miranda .
ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (08) :879-892
[8]   Particulate concentrations within a reduced-scale room operated at various air exchange rates [J].
Faulkner, W. Brock ;
Memarzadeh, Farhad ;
Riskowski, Gerald ;
Hamilton, Keith ;
Chang, Ching-Zu ;
Chang, Jieh-Ren .
BUILDING AND ENVIRONMENT, 2013, 65 :71-80
[9]   Solution for sudden contamination transport through air duct system: Under a puff release [J].
Gao, Jun ;
Zeng, Lingjie ;
Wu, Li ;
Ding, Xihui ;
Zhang, Xu .
BUILDING AND ENVIRONMENT, 2016, 100 :19-27
[10]   Possible aerosol transmission of COVID-19 and special precautions in dentistry [J].
Ge, Zi-yu ;
Yang, Lu-ming ;
Xia, Jia-jia ;
Fu, Xiao-hui ;
Zhang, Yan-zhen .
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2020, 21 (05) :361-368