Optical method for the determination of the oxygen-transfer capacity of small bioreactors based on sulfite oxidation

被引:79
作者
Hermann, R [1 ]
Walther, N [1 ]
Maier, U [1 ]
Büchs, J [1 ]
机构
[1] Rhein Westfal TH Aachen, Dept Biochem Engn, Sammelbau Biol, D-52074 Aachen, Germany
关键词
oxygen transfer; sulfite oxidation; optical method; shaking flasks; test tubes; microtiter plates;
D O I
10.1002/bit.1126
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The growth of microorganisms may be limited by operating conditions which provide an inadequate supply of oxygen. To determine the oxygen-transfer capacities of small-scale bioreactors such as shaking flasks, test tubes, and microtiter plates, a noninvasive easy-to-use optical method based on sulfite oxidation has been developed. The model system of sodium sulfite was first optimized in shaking-flask experiments for this special application. The reaction conditions (pH, buffer, and catalyst concentration) were adjusted to obtain a constant oxygen transfer rate for the whole period of the sulfite oxidation reaction. The sharp decrease of the pH at the end of the oxidation, which is typical for this reaction, is visualized by adding a pH dye and used to measure the length of the reaction period. The oxygen-transfer capacity can then be calculated by the oxygen consumed during the complete stoichiometric transformation of sodium sulfite and the visually determined reaction time. The suitability of this optical measuring method for the determination of oxygen-transfer capacities in small-scale bioreactors was confirmed with an independent physical method applying an oxygen electrode. The correlation factor for the maximum oxygen-transfer capacity between the chemical model system and a culture of Pseudomonas putida CA-3 was determined in shaking flasks. The newly developed optical measuring method was finally used for the determination of oxygen-transfer capacities of different types of transparent small-scale bioreactors. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:355 / 363
页数:9
相关论文
共 35 条
  • [1] DIFFUSIVITIES OF GASES IN AQUEOUS-ELECTROLYTE SOLUTIONS
    AKITA, K
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1981, 20 (01): : 89 - 94
  • [2] Device for sterile online measurement of the oxygen transfer rate in shaking flasks
    Anderlei, T
    Büchs, J
    [J]. BIOCHEMICAL ENGINEERING JOURNAL, 2001, 7 (02) : 157 - 162
  • [3] ANDERLEI T, 1999, Patent No. 0905229
  • [4] Bailey JE., 1986, BIOCH ENG FUNDAMENTA, P421
  • [5] DYNAMIC MEASUREMENT OF VOLUMETRIC OXYGEN TRANSFER COEFFICIENT IN FERMENTATION SYSTEMS
    BANDYOPA.B
    HUMPHREY, AE
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1967, 9 (04) : 533 - &
  • [6] OXYGEN TRANSFER AND AGITATION IN SUBMERGED FERMENTATIONS - MASS TRANSFER OF OXYGEN IN SUBMERGED FERMENTATION OF STREPTOMYCES-GRISEUS
    BARTHOLOMEW, WH
    KAROW, EO
    SFAT, MR
    WILHELM, RH
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1950, 42 (09): : 1801 - 1809
  • [7] Performance of agitated gas-liquid contactors
    Cooper, CM
    Fernstrom, GA
    Miller, SA
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1944, 36 : 504 - 509
  • [8] Methods for intense aeration, growth, storage, and replication of bacterial strains in microtiter plates
    Duetz, WA
    Rüedi, L
    Hermann, R
    O'Connor, K
    Büchs, J
    Witholt, B
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2000, 66 (06) : 2641 - 2646
  • [9] Evans C. G. T., 1970, METHOD MICROBIOL, V2, P277, DOI [DOI 10.1016/S0580-9517(08)70227-7, 10.1016/S0580-9517(08)70227-7]
  • [10] Fuller E.C., 1941, J AM CHEM SOC, V63, P1644