Nonlinear Difference Imaging to Image Local Conductivity of Single-Layer Graphene Using Electrical Impedance Tomography

被引:3
作者
Khambampati, Anil Kumar [1 ,2 ]
Rahman, Sheik Abdur [1 ,2 ]
Sharma, Sunam Kumar [1 ,2 ]
Kim, Woo Young [1 ,2 ]
Kim, Kyung Youn [1 ,2 ]
机构
[1] Jeju Natl Univ, Elect Engn Dept, Jeju 63243, South Korea
[2] Jeju Natl Univ, Dept Elect Engn, Fac Appl Energy Syst Engn, Jeju 63243, South Korea
基金
新加坡国家研究基金会;
关键词
Graphene; Conductivity; Imaging; Electrical impedance tomography; Voltage measurement; Mathematical models; Electrodes; Conductivity estimation; electrical impedance tomography (EIT); graphene; inverse problem; modeling errors; LARGE-AREA; FILMS;
D O I
10.1109/TIM.2022.3147894
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Single-layer graphene synthesized using the chemical vapor deposition (CVD) technique contains defects on the graphene surface that are formed during the growth and transfer process. These defects influence the graphene electrical characteristics, especially the conductivity distribution. Nondestructive characterization of graphene samples is therefore essential for developing single-layer graphene devices. Electrical impedance tomography (EIT), a low-cost nondestructive method with high temporal resolution characteristics, can be applied to obtain the local conductivity distribution. Due to the very high conductivity of the background and inaccurate knowledge of contact impedances, the conventional absolute imaging methods do not give desired conductivity reconstruction for graphene. This study uses a nonlinear difference imaging (NDI) approach to estimate the local conductivity changes across the graphene surface quantitatively. In NDI, the conductivity after the change is parameterized as a linear combination of initial and the conductivity change. The conductivity change restricted to the region of interest (ROI) is determined using the Otsu method. The NDI with Otsu method (NDIWO) estimates the initial distribution and conductivity changes simultaneously from the two datasets measured at different time intervals. NDIWO tolerates modeling errors to some extent and quantitively provides more accurate local conductivity changes. The feasibility of NDIWO is tested with numerical simulations and experiments with graphene wafer of size 2.5 cm x 2.5 cm, and results show that the proposed method is successful in estimating the conductivity changes with better accuracy than conventional absolute and linear difference imaging.
引用
收藏
页数:12
相关论文
共 51 条
  • [1] Impedance imaging of lung ventilation: Do we need to account for chest expansion?
    Adler, A
    Guardo, R
    Berthiaume, Y
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (04) : 414 - 420
  • [2] Nanoscale investigation of charge transport at the grain boundaries and wrinkles in graphene film
    Ahmad, Muneer
    An, Hyosub
    Kim, Yong Seung
    Lee, Jae Hong
    Jung, Jongwan
    Chun, Seung-Hyun
    Seo, Yongho
    [J]. NANOTECHNOLOGY, 2012, 23 (28)
  • [3] Imaging, Simulation, and Electrostatic Control of Power Dissipation in Graphene Devices
    Bae, Myung-Ho
    Ong, Zhun-Yong
    Estrada, David
    Pop, Eric
    [J]. NANO LETTERS, 2010, 10 (12) : 4787 - 4793
  • [4] Bae S, 2010, NAT NANOTECHNOL, V5, P574, DOI [10.1038/nnano.2010.132, 10.1038/NNANO.2010.132]
  • [5] Barber D C, 1987, Clin Phys Physiol Meas, V8 Suppl A, P47, DOI 10.1088/0143-0815/8/4A/006
  • [6] Bera T. K., 2010, 2010 International Conference on Systems in Medicine and Biology (ICSMB), P278, DOI 10.1109/ICSMB.2010.5735387
  • [7] Applications of Electrical Impedance Tomography (EIT): A Short Review
    Bera, Tushar Kanti
    [J]. 3RD INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS (ICCS-2017), 2018, 331
  • [8] Brown B. H., 2003, Journal of Medical Engineering & Technology, V27, P97, DOI 10.1080/0309190021000059687
  • [9] Graphene mobility mapping
    Buron, Jonas D.
    Pizzocchero, Filippo
    Jepsen, Peter U.
    Petersen, Dirch H.
    Caridad, Jose M.
    Jessen, Bjarke S.
    Booth, Timothy J.
    Boggild, Peter
    [J]. SCIENTIFIC REPORTS, 2015, 5
  • [10] Electrical impedance tomography
    Cheney, M
    Isaacson, D
    Newell, JC
    [J]. SIAM REVIEW, 1999, 41 (01) : 85 - 101